High integrity solid-contact (SC) polymeric ion sensors have been produced by using spin casting and electropolymerization techniques in the preparation of the SC employing the conductive polymer, poly(3-octylthiophene) [POT]. The physical and chemical integrity of the POT SCs have been evaluated using scanning electron microscopy (SEM), atomic force microscopy (AFM), secondary ion mass spectrometry (SIMS) and X-ray photoelectron spectroscopy (XPS). Furthermore, the electrochemical stability of SC polymeric ion sensors has been investigated using electrochemical impedance spectroscopy (EIS). The results of this study demonstrate that electropolymerization and spin casting methods also comprising annealing of the synthesized SC film are capable of producing SCs that are relatively free of imperfections such as pores and pinholes. This leads to electrochemically stable and robust polymeric ion sensors where the SC/sensor interface is resistant to the formation of a detrimental water layer that normally gives rise to spurious ion fluxes and a degradation in the sensitivity and selectivity of the SC polymeric ion sensor.

Entities:  

Year:  2009        PMID: 20802817      PMCID: PMC2929028          DOI: 10.1007/s10008-008-0600-9

Source DB:  PubMed          Journal:  J Solid State Electrochem        ISSN: 1432-8488            Impact factor:   2.647


  15 in total

Review 1.  Electroanalysis and biosensors.

Authors:  J Wang
Journal:  Anal Chem       Date:  1999-06-15       Impact factor: 6.986

2.  Use of an ion-selective electrode to determine free Ca ion concentration in the milk of various mammals.

Authors:  Nissim Silanikove; Fira Shapiro; Avi Shamay
Journal:  J Dairy Res       Date:  2003-05       Impact factor: 1.904

3.  Potentiometry at trace levels in confined samples: ion-selective electrodes with subfemtomole detection limits.

Authors:  Adam Malon; Tamas Vigassy; Eric Bakker; Ernö Pretsch
Journal:  J Am Chem Soc       Date:  2006-06-28       Impact factor: 15.419

4.  Potentiometric immunoassay with quantum dot labels.

Authors:  Reto Thürer; Tamás Vigassy; Martina Hirayama; Joseph Wang; Eric Bakker; Ernö Pretsch
Journal:  Anal Chem       Date:  2007-05-26       Impact factor: 6.986

5.  Solid contact potentiometric sensors for trace level measurements.

Authors:  Karin Y Chumbimuni-Torres; Nastassia Rubinova; Aleksandar Radu; Lauro T Kubota; Eric Bakker
Journal:  Anal Chem       Date:  2006-02-15       Impact factor: 6.986

6.  Potentiometric ion sensors.

Authors:  Johan Bobacka; Ari Ivaska; Andrzej Lewenstam
Journal:  Chem Rev       Date:  2008-01-12       Impact factor: 60.622

7.  Evidence of a water layer in solid-contact polymeric ion sensors.

Authors:  Roland De Marco; Jean-Pierre Veder; Graeme Clarke; Andrew Nelson; Kathryn Prince; Ernö Pretsch; Eric Bakker
Journal:  Phys Chem Chem Phys       Date:  2007-10-19       Impact factor: 3.676

8.  Elimination of undesirable water layers in solid-contact polymeric ion-selective electrodes.

Authors:  Jean-Pierre Veder; Roland De Marco; Graeme Clarke; Ryan Chester; Andrew Nelson; Kathryn Prince; Ernö Pretsch; Eric Bakker
Journal:  Anal Chem       Date:  2008-08-01       Impact factor: 6.986

9.  Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers.

Authors:  J Bobacka
Journal:  Anal Chem       Date:  1999-11-01       Impact factor: 6.986

10.  Intracellular pH regulation in cultured embryonic chick heart cells. Na(+)-dependent Cl-/HCO3- exchange.

Authors:  S Liu; D Piwnica-Worms; M Lieberman
Journal:  J Gen Physiol       Date:  1990-12       Impact factor: 4.086

View more
  2 in total

1.  Electrochemical impedance spectroscopy-a simple method for the characterization of polymer inclusion membranes containing aliquat 336.

Authors:  Michelle O'Rourke; Noel Duffy; Roland De Marco; Ian Potter
Journal:  Membranes (Basel)       Date:  2011-06-23

Review 2.  Calibration Update and Drift Correction for Electronic Noses and Tongues.

Authors:  Alisa Rudnitskaya
Journal:  Front Chem       Date:  2018-09-25       Impact factor: 5.221

  2 in total