Literature DB >> 21659036

Geometric calibration of a micro-CT system and performance for insect imaging.

Zhanli Hu1, Jianbao Gui, Jing Zou, Junyan Rong, Qiyang Zhang, Hairong Zheng, Dan Xia.   

Abstract

Micro-CT with a high spatial resolution in combination with computer-based-reconstruction techniques is considered a powerful tool for morphological study of insects. The quality of CT images crucially depends on the precise knowledge of the scan geometry of the micro-CT system. In this paper, we have proposed a method to calculate the deviation of rotating axis for compensating deficiency of existing methods. A practical application of this geometric calibration method of the micro-CT system for insect imaging is presented. We have performed the computer-simulation study and experimental study with our prototype micro-CT system. The results demonstrate that the proposed technique is accurate and robust. In addition, we have evaluated the imaging characteristics of the detector in terms of modulation-transfer function (MTF). Finally, insect imaging performance and image reconstruction from data acquired with different energies are presented.

Mesh:

Year:  2011        PMID: 21659036     DOI: 10.1109/TITB.2011.2159012

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  5 in total

1.  Self-calibration of cone-beam CT geometry using 3D-2D image registration.

Authors:  S Ouadah; J W Stayman; G J Gang; T Ehtiati; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-10       Impact factor: 3.609

2.  A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories.

Authors:  M W Jacobson; M D Ketcha; S Capostagno; A Martin; A Uneri; J Goerres; T De Silva; S Reaungamornrat; R Han; A Manbachi; J W Stayman; S Vogt; G Kleinszig; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2018-01-16       Impact factor: 3.609

3.  Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays.

Authors:  Changhui Jiang; Na Zhang; Juan Gao; Zhanli Hu
Journal:  PLoS One       Date:  2017-11-29       Impact factor: 3.240

4.  An improved statistical iterative algorithm for sparse-view and limited-angle CT image reconstruction.

Authors:  Zhanli Hu; Juan Gao; Na Zhang; Yongfeng Yang; Xin Liu; Hairong Zheng; Dong Liang
Journal:  Sci Rep       Date:  2017-09-06       Impact factor: 4.379

5.  PWLS-PR: low-dose computed tomography image reconstruction using a patch-based regularization method based on the penalized weighted least squares total variation approach.

Authors:  Jing Fu; Fei Feng; Huimin Quan; Qian Wan; Zixiang Chen; Xin Liu; Hairong Zheng; Dong Liang; Guanxun Cheng; Zhanli Hu
Journal:  Quant Imaging Med Surg       Date:  2021-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.