Literature DB >> 21656297

Development and validation for identity testing of I-DNADuo, a combination of I-DNA1 and a new multiplex system, I-DNA2.

Adrian Odriozola1, Jose María Aznar, David Celorrio, Maria Luisa Bravo, Juan Jose Builes, Marian Martinez de Pancorbo.   

Abstract

The I-DNADuo multiplex system combination is composed of previously validated I-DNA1 and a new short tandem repeat (STR) multiplex named I-DNA2 that analyses 11 STR loci plus amelogenin. I-DNADuo, with amplicon sizes ranging from 57 to 298 bp, is specifically designed to analyse amelogenin and 15 STR loci (ten of them plus amelogenin in duplicate), including all the STR loci of the CODIS, ISSL and ECL databases, and seven of the eight in GCL. The validation of I-DNADuo shows that it is a highly sensitive, robust multiplex system for obtaining individual genetic profiles and for detecting and preventing allelic dropouts.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21656297     DOI: 10.1007/s00414-011-0585-2

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  16 in total

1.  Validation of the AMPFlSTR SGM plus system for use in forensic casework.

Authors:  E A Cotton; R F Allsop; J L Guest; R R Frazier; P Koumi; I P Callow; A Seager; R L Sparkes
Journal:  Forensic Sci Int       Date:  2000-08-14       Impact factor: 2.395

2.  A brief history of the formation of DNA databases in forensic science within Europe.

Authors:  P D Martin; H Schmitter; P M Schneider
Journal:  Forensic Sci Int       Date:  2001-06-15       Impact factor: 2.395

3.  Developmental validation of a single-tube amplification of the 13 CODIS STR loci, D2S1338, D19S433, and amelogenin: the AmpFlSTR Identifiler PCR Amplification Kit.

Authors:  Patrick J Collins; Lori K Hennessy; Craig S Leibelt; Rhonda K Roby; Dennis J Reeder; Paul A Foxall
Journal:  J Forensic Sci       Date:  2004-11       Impact factor: 1.832

4.  International perspectives on forensic DNA databases.

Authors:  Christopher Asplen; Smith Alling Lane
Journal:  Forensic Sci Int       Date:  2004-12-02       Impact factor: 2.395

5.  Concordance study between the AmpFlSTR MiniFiler PCR amplification kit and conventional STR typing kits.

Authors:  Carolyn R Hill; Margaret C Kline; Julio J Mulero; Robert E Lagacé; Chien-Wei Chang; Lori K Hennessy; John M Butler
Journal:  J Forensic Sci       Date:  2007-06-06       Impact factor: 1.832

6.  Development and validation of the AmpFlSTR MiniFiler PCR Amplification Kit: a MiniSTR multiplex for the analysis of degraded and/or PCR inhibited DNA.

Authors:  Julio J Mulero; Chien Wei Chang; Robert E Lagacé; Dennis Y Wang; Jennifer L Bas; Timothy P McMahon; Lori K Hennessy
Journal:  J Forensic Sci       Date:  2008-07       Impact factor: 1.832

Review 7.  Short tandem repeat typing technologies used in human identity testing.

Authors:  John M Butler
Journal:  Biotechniques       Date:  2007-10       Impact factor: 1.993

8.  False homozygosities at CSF1PO loci revealed by discrepancies between two kits in Chinese population.

Authors:  Xian-Dun Zhai; Xiao-Qi Xue; Yao-Nan Mo; Gui-Sei Zhao; Hong-Wei Ai; Yi Ye; Zheng Wang; Yi-Ping Hou
Journal:  Int J Legal Med       Date:  2009-10-30       Impact factor: 2.686

9.  Development and validation of I-DNA1: a 15-Loci multiplex system for identity testing.

Authors:  A Odriozola; J M Aznar; D Celorrio; M L Bravo; J J Builes; J F Val-Bernal; Marian M de Pancorbo
Journal:  Int J Legal Med       Date:  2011-01-22       Impact factor: 2.686

10.  A rapid and quantitative DNA sex test: fluorescence-based PCR analysis of X-Y homologous gene amelogenin.

Authors:  K M Sullivan; A Mannucci; C P Kimpton; P Gill
Journal:  Biotechniques       Date:  1993-10       Impact factor: 1.993

View more
  1 in total

1.  Development and validation of a multiplex reaction analyzing eight miniSTRs of the X chromosome for identity and kinship testing with degraded DNA.

Authors:  María Castañeda; Adrián Odriozola; Javier Gómez; María T Zarrabeitia
Journal:  Int J Legal Med       Date:  2012-11-28       Impact factor: 2.686

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.