Literature DB >> 21654065

Comparison of electrode materials for the use of retinal prosthesis.

Niina Onnela1, Hirotaka Takeshita, Yoshiuki Kaiho, Toshiya Kojima, Risato Kobayashi, Tetsu Tanaka, Jari Hyttinen.   

Abstract

Retinal implants may provide vision for people suffering from photoreceptor degeneration caused by different eye diseases. Electrode size in retinal implant should be decreased in order to increase the resolution provided by the implant. We defined electric properties of five different electrode materials (Au, Ir-b, Ti, TiN, Pt-b) widely used in retinal prostheses. The comparison of different electrode materials requires that the electrical properties of different materials are defined using exactly the same measurement conditions and devices. Existing studies about electrode material properties are often made using slightly different measurement parameters or electrode processing conditions making the comparison between different materials difficult. Here, the electrochemical characterization included cyclic voltammetry and electrochemical impedance spectroscopy. Ir-b and Pt-b had greater charge injection capacity than other materials. The fabricated material samples showed that in this experiment the electrode diameter larger than 200 μm should be used to suppress irreversible reaction of stimulus electrodes with the needed stimulus currents. Thus, either we have to find novel electrode materials or surface treatment methods to decrease the electrode area providing increased electrode and pixel number of the prosthesis or we have to show that stimulus currents smaller than 40 μA are enough to induce phosphenes.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21654065     DOI: 10.3233/BME-2011-0658

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  6 in total

Review 1.  Retinal implants: emergence of a multidisciplinary field.

Authors:  Gislin Dagnelie
Journal:  Curr Opin Neurol       Date:  2012-02       Impact factor: 5.710

2.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

Review 3.  [Visual prostheses].

Authors:  P Walter
Journal:  Ophthalmologe       Date:  2016-02       Impact factor: 1.059

4.  Electrical Characterization of 3D Au Microelectrodes for Use in Retinal Prostheses.

Authors:  Sangmin Lee; Jae Hyun Ahn; Jong-Mo Seo; Hum Chung; Dong-Il Dan Cho
Journal:  Sensors (Basel)       Date:  2015-06-17       Impact factor: 3.576

Review 5.  Organic electrode coatings for next-generation neural interfaces.

Authors:  Ulises A Aregueta-Robles; Andrew J Woolley; Laura A Poole-Warren; Nigel H Lovell; Rylie A Green
Journal:  Front Neuroeng       Date:  2014-05-27

6.  In vitro and in vivo evaluation of a photosensitive polyimide thin-film microelectrode array suitable for epiretinal stimulation.

Authors:  Xia Jiang; Xiaohong Sui; Yiliang Lu; Yan Yan; Chuanqing Zhou; Liming Li; Qiushi Ren; Xinyu Chai
Journal:  J Neuroeng Rehabil       Date:  2013-05-29       Impact factor: 4.262

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.