Literature DB >> 21651392

Immediate versus delayed IUD insertion after uterine aspiration.

Paula H Bednarek1, Mitchell D Creinin, Matthew F Reeves, Carrie Cwiak, Eve Espey, Jeffrey T Jensen.   

Abstract

BACKGROUND: Intrauterine devices (IUDs) provide highly effective, reversible, long-term contraception that is appropriate for many women after first-trimester uterine aspiration. However, the effects of immediate versus delayed IUD insertion after uterine aspiration on rates of complications and IUD use are uncertain.
METHODS: We performed a randomized noninferiority trial involving women undergoing uterine aspiration for induced or spontaneous abortion at 5 to 12 weeks of gestation who desired an IUD. Subjects were randomly assigned (in a 5:6 ratio) to IUD insertion immediately after the procedure or 2 to 6 weeks afterward (delayed insertion). The primary outcome was the rate of IUD expulsion 6 months after IUD insertion; an expulsion rate 8 percentage points higher in the immediate-insertion group was defined as inferior.
RESULTS: Among 575 women who underwent randomization, an IUD was inserted in 100% (258 of 258) of the women in the immediate-insertion group and in 71.3% (226 of 317) of those in the delayed-insertion group (difference, 28.7 percentage points; 95% confidence interval [CI], 23.7 to 33.7). The 6-month expulsion risk was 5.0% (13 of 258 women) after immediate insertion and 2.7% (6 of 226) after delayed insertion (difference, 2.3 percentage points; 95% CI, -1.0 to 5.8), which was consistent with the predefined criterion for noninferiority. Six-month rates of IUD use were higher in the immediate-insertion group (92.3%, vs. 76.6% after delayed insertion; P<0.001). Adverse events were rare and did not differ significantly between groups. No pregnancies occurred in the immediate-insertion group; five occurred in the delayed-insertion group (P=0.07), all in women who never received an IUD.
CONCLUSIONS: The 6-month rate of expulsion of an IUD after immediate insertion was higher than but not inferior to that after delayed insertion. Immediate insertion resulted in higher rates of IUD use at 6 months, without an increased risk of complications. (Funded by the Susan Thompson Buffett Foundation; ClinicalTrials.gov number, NCT00562276.).

Entities:  

Mesh:

Year:  2011        PMID: 21651392     DOI: 10.1056/NEJMoa1011600

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  32 in total

1.  Intrauterine contraceptive devices following termination of pregnancy.

Authors:  Athol Kent
Journal:  Rev Obstet Gynecol       Date:  2011

2.  Immediate post-abortion insertion of intrauterine contraceptives (IUC) in a diverse urban population.

Authors:  DeShawn Taylor; Shannon Connolly; Sue Ann Ingles; Carey Watson; Penina Segall-Gutierrez
Journal:  J Immigr Minor Health       Date:  2014-06

Review 3.  Anti-adhesion therapy following operative hysteroscopy for treatment of female subfertility.

Authors:  Jan Bosteels; Steven Weyers; Thomas M D'Hooghe; Helen Torrance; Frank J Broekmans; Su Jen Chua; Ben Willem J Mol
Journal:  Cochrane Database Syst Rev       Date:  2017-11-27

4.  Acceptability of randomization to levonorgestrel versus copper intrauterine device among women requesting IUD insertion for contraception.

Authors:  Sharon L Achilles; Beatrice A Chen; Jessica K Lee; Aileen M Gariepy; Mitchell D Creinin
Journal:  Contraception       Date:  2015-08-18       Impact factor: 3.375

5.  Immediate postabortion intrauterine device insertion: continuation and satisfaction.

Authors:  Colleen McNicholas; Taylor Hotchkiss; Tessa Madden; Qiuhong Zhao; Jenifer Allsworth; Jeffrey F Peipert
Journal:  Womens Health Issues       Date:  2012 Jul-Aug

6.  Postabortion Contraceptive Use and Continuation When Long-Acting Reversible Contraception Is Free.

Authors:  Vinita Goyal; Caitlin Canfield; Abigail R A Aiken; Amna Dermish; Joseph E Potter
Journal:  Obstet Gynecol       Date:  2017-04       Impact factor: 7.661

Review 7.  Eliminating health disparities in unintended pregnancy with long-acting reversible contraception (LARC).

Authors:  Caitlin Parks; Jeffrey F Peipert
Journal:  Am J Obstet Gynecol       Date:  2016-02-12       Impact factor: 8.661

8.  One-year continuation of copper or levonorgestrel intrauterine devices initiated at the time of emergency contraception.

Authors:  J N Sanders; D K Turok; P A Royer; I S Thompson; L M Gawron; K E Storck
Journal:  Contraception       Date:  2017-06-05       Impact factor: 3.375

9.  Funding policies and postabortion long-acting reversible contraception: results from a cluster randomized trial.

Authors:  Corinne H Rocca; Kirsten M J Thompson; Suzan Goodman; Carolyn L Westhoff; Cynthia C Harper
Journal:  Am J Obstet Gynecol       Date:  2015-12-12       Impact factor: 8.661

10.  Uterine dimensions and intrauterine device malposition: can ultrasound predict displacement or expulsion before it happens?

Authors:  Feyza Nur İncesu Çintesun; Ersin Çintesun; Ümmügülsüm Esenkaya; Oğuzhan Günenc
Journal:  Arch Gynecol Obstet       Date:  2020-08-03       Impact factor: 2.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.