Literature DB >> 21644610

Evaluation of a sheath flow cuvette for postcolumn fluorescence derivatization of DNA fragments separated by capillary electrophoresis.

W F Nirode1, T D Staller, R O Cole, M J Sepaniak.   

Abstract

The investigation and evaluation of the sheath flow cell as a reaction chamber to postcolumn fluorescently derivatize DNA fragments separated by capillary electrophoresis is described herein. Use of the sheath flow cell arrangement facilitates the mixing of the intercalating dye, ethidium bromide (EB), and the effluent from the separation capillary by diffusion without a high degree of band dispersion. Theoretical plate counts of >1 × 10(6) are reported with the postcolumn derivatization technique, and resolution of all of the fragments in a φx-174-HaeIII digest is achieved. Optimization of experimental parameters such as flow rate, position of the detection zone, and EB concentration is examined. A limit of detection in the low nanograms-per-milliliter range with a linear dynamic range over 3 orders of magnitude is reported for a sample of φx-174-HaeIII digest. Evaluation of postcolumn derivatization for the investigation of DNA-protein interactions is demonstrated. The integrity of a DNA-trp-repressor protein interaction is maintained with the postcolumn approach but is compromised when EB is added to the running buffer.

Entities:  

Year:  1998        PMID: 21644610     DOI: 10.1021/ac970560p

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  The use of capillary electrophoresis for DNA polymorphism analysis.

Authors:  Keith R Mitchelson
Journal:  Mol Biotechnol       Date:  2003-05       Impact factor: 2.695

2.  Optimization of post-column reactor radius in capillary high performance liquid chromatography Effect of chromatographic column diameter and particle diameter.

Authors:  Hongjuan Xu; Stephen G Weber
Journal:  J Chromatogr A       Date:  2006-02-21       Impact factor: 4.759

3.  Simplified sheath flow cuvette design for ultrasensitive laser induced fluorescence detection in capillary electrophoresis.

Authors:  Oluwatosin O Dada; Bonnie J Huge; Norman J Dovichi
Journal:  Analyst       Date:  2012-05-18       Impact factor: 4.616

4.  Effect of an open tube in series with a packed capillary column on liquid chromatographic performance. The influence of particle diameter, temperature, and system pressure.

Authors:  Hongjuan Xu; Stephen G Weber
Journal:  J Chromatogr A       Date:  2008-12-27       Impact factor: 4.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.