Effect of an open tube in series with a packed capillary column on liquid chromatographic performance. The influence of particle diameter, temperature, and system pressure.

Hongjuan Xu1, Stephen G Weber.   

Abstract

A postcolumn reactor or a simple open tube connecting a capillary column to, for example, a mass spectrometer affects the performance of a capillary liquid chromatography system in two ways: stealing pressure from the column and adding band-spreading. This effect is especially intolerable in fast separations. Our calculations show that in the presence of a 25 microm radius postcolumn reactor, column (50 microm radius) efficiency (number of theoretical plates) is severely reduced by more than 75% with a t(0) of 10s and a particle diameter from 1 to 5 microm for unretained solutes at room temperature. Therefore, it is necessary to minimize the reactor's effect and to improve the column efficiency by optimizing postcolumn conditions. We derived an equation that defines the observed number of theoretical plates (N(obs)) taking into account the two effects stated above, which is a function of the maximum pressure P(m), the particle diameter d(p), the reactor radius a(r), the column radius a(c), the desired dead time t(0), the column temperature T and zone capacity factor k''. Poppe plots were obtained by calculations using this equation. The results show that for a t(0) shorter than 18s, a P(m) of 4000 psi, and a d(p) of 1.7 microm, a 5 microm radius reactor has to be used. Such a small reactor is difficult to fabricate. Fortunately, high temperature helps to minimize the reactor effect so that reactors with manageable radius (larger than 12.5 microm) can be used in many practical conditions. Furthermore, solute retention diminishes the influence of a postcolumn reactor. Thus, a 12.5 microm reactor supersedes a 5 microm reactor for retained solutes even at a t(0) of 5s (k''>3.8, or k'>2.0).

Entities:  

Mesh:

Year:  2008        PMID: 19150071      PMCID: PMC2663968          DOI: 10.1016/j.chroma.2008.12.060

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  10 in total

1.  Ultrahigh pressure liquid chromatography using elevated temperature.

Authors:  Yanqiao Xiang; Yansheng Liu; Milton L Lee
Journal:  J Chromatogr A       Date:  2006-02-03       Impact factor: 4.759

2.  Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems. I: Intrinsic performance comparison.

Authors:  D Cabooter; S Heinisch; J L Rocca; D Clicq; G Desmet
Journal:  J Chromatogr A       Date:  2007-01-13       Impact factor: 4.759

3.  Optimization of post-column reactor radius in capillary high performance liquid chromatography Effect of chromatographic column diameter and particle diameter.

Authors:  Hongjuan Xu; Stephen G Weber
Journal:  J Chromatogr A       Date:  2006-02-21       Impact factor: 4.759

4.  High throughput liquid chromatography with sub-2 microm particles at high pressure and high temperature.

Authors:  Dao T-T Nguyen; Davy Guillarme; Sabine Heinisch; Marie-Pierre Barrioulet; Jean-Louis Rocca; Serge Rudaz; Jean-Luc Veuthey
Journal:  J Chromatogr A       Date:  2007-08-17       Impact factor: 4.759

5.  Kinetic plot equations for evaluating the real performance of the combined use of high temperature and ultra-high pressure in liquid chromatography. Application to commercial instruments and 2.1 and 1 mm I.D. columns.

Authors:  Sabine Heinisch; Gert Desmet; David Clicq; Jean-Louis Rocca
Journal:  J Chromatogr A       Date:  2008-07-19       Impact factor: 4.759

6.  Evaluation of a sheath flow cuvette for postcolumn fluorescence derivatization of DNA fragments separated by capillary electrophoresis.

Authors:  W F Nirode; T D Staller; R O Cole; M J Sepaniak
Journal:  Anal Chem       Date:  1998-01-01       Impact factor: 6.986

7.  Influence of chemical kinetics on postcolumn reaction in a capillary Taylor reactor with catechol analytes and photoluminescence following electron transfer.

Authors:  Moon Chul Jung; Stephen G Weber
Journal:  Anal Chem       Date:  2005-02-15       Impact factor: 6.986

8.  High temperature fast chromatography of proteins using a silica-based stationary phase with greatly enhanced low pH stability.

Authors:  Xiqin Yang; Lianjia Ma; Peter W Carr
Journal:  J Chromatogr A       Date:  2005-06-24       Impact factor: 4.759

9.  Analysis of the performance of a flow reactor for use with microcolumn HPLC.

Authors:  Amy T Beisler; Eskil Sahlin; Kathleen E Schaefer; Stephen G Weber
Journal:  Anal Chem       Date:  2004-02-01       Impact factor: 6.986

10.  Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.

Authors:  Fabrice Gritti; Georges Guiochon
Journal:  J Chromatogr A       Date:  2008-02-15       Impact factor: 4.759

  10 in total
  3 in total

1.  Optimization for speed and sensitivity in capillary high performance liquid chromatography. The importance of column diameter in online monitoring of serotonin by microdialysis.

Authors:  Jing Zhang; Yansheng Liu; Andrea Jaquins-Gerstl; Zhan Shu; Adrian C Michael; Stephen G Weber
Journal:  J Chromatogr A       Date:  2012-06-09       Impact factor: 4.759

2.  Capillary ultrahigh performance liquid chromatography with elevated temperature for sub-one minute separations of basal serotonin in submicroliter brain microdialysate samples.

Authors:  Yansheng Liu; Jing Zhang; Xiaomi Xu; Moe K Zhao; Anne M Andrews; Stephen G Weber
Journal:  Anal Chem       Date:  2010-11-09       Impact factor: 6.986

3.  Electroosmotic sampling. Application to determination of ectopeptidase activity in organotypic hippocampal slice cultures.

Authors:  Hongjuan Xu; Yifat Guy; Amy Hamsher; Guoyue Shi; Mats Sandberg; Stephen G Weber
Journal:  Anal Chem       Date:  2010-08-01       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.