Literature DB >> 21644145

Performance and modeling of a vertical flow constructed wetland-maturation pond system.

Georgios D Gikas1, Vassilios A Tsihrintzis, Christos S Akratos.   

Abstract

A 32-month monitoring program is presented in a vertical flow constructed wetland facility, located in North Greece. The monitoring campaigns were organized every 15 days. Water quality samples were collected at the inlet, at four intermediate points (i.e., at the end of each treatment stage) and at the outlet of the system. Temperature, electrical conductivity, pH and dissolved oxygen (DO) were measured in-situ with the use of appropriate instruments at the same points of water sample collection. Water samples were analyzed for biochemical oxygen demand (BOD), chemical oxygen demand (COD), total Kjeldahl nitrogen (TKN), ammonia, nitrate, nitrite, total phosphorus (TP), ortho-phosphate (OP), total suspended solids (TSS) and total coliforms (TC). Mean removal efficiencies for the monitoring period were: 90.8% for BOD, 89.0% for COD, 83.9% for TKN, 83.8% for ammonia, 38.8% for TP, 17.4% for OP, 90.4% for TSS and 99.9% for TC, indicating, for most pollutant, excellent performance of this constructed wetland (CW) system under Mediterranean climate conditions. Results showed that organic matter, TSS, TKN, ammonia, TP, OP and TC removal is not significantly affected by temperature. The collected removal data were used to produce appropriate parameter values for first-order k-C* models and develop simple models based on stepwise multiple linear regression (SMLR) analysis, in an effort to predict CW performance. These models were verified using data from another facility located in the same region. The results showed that the predictions correlate well with measured values, leading to the conclusion that the first-order models and the developed SMLR models are useful tools in the design of vertical flow (VF) CWs.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21644145     DOI: 10.1080/10934529.2011.571579

Source DB:  PubMed          Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng        ISSN: 1093-4529            Impact factor:   2.269


  3 in total

1.  Effect of operational and design parameters on performance of pilot-scale horizontal subsurface flow constructed wetlands treating university campus wastewater.

Authors:  Vassiliki Papaevangelou; Georgios D Gikas; Vassilios A Tsihrintzis
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-07       Impact factor: 4.223

2.  Evaluation of Waste Stabilization Pond Efficiency and Its Effluent Water Quality: a Case Study of Kito Furdisa Campus, Jimma University, Southwest Ethiopia.

Authors:  Belay Desye; Biniam Belete; Embay Amare Alemseged; Yonas Angaw; Zinabu Asfaw Gebrezgi
Journal:  ScientificWorldJournal       Date:  2022-05-17

3.  Treatment performance and microorganism community structure of integrated vertical-flow constructed wetland plots for domestic wastewater.

Authors:  Su-qing Wu; Jun-jun Chang; Yanran Dai; Zhen-bin Wu; Wei Liang
Journal:  Environ Sci Pollut Res Int       Date:  2012-11-22       Impact factor: 4.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.