Literature DB >> 27388592

Effect of operational and design parameters on performance of pilot-scale horizontal subsurface flow constructed wetlands treating university campus wastewater.

Vassiliki Papaevangelou1, Georgios D Gikas2, Vassilios A Tsihrintzis3.   

Abstract

Three horizontal subsurface flow (HSF) pilot-scale constructed wetland (CW) units operated for 3 years treating municipal wastewater originating from a university campus. The main objective of the study was the evaluation of the performance of these systems under several operational, design, and climatic conditions. Several parameters and factors were investigated, including the influence of temperature, vegetation, and hydraulic residence time. The results were compared to those of a previous study conducted in the same pilot-scale units and under the same operational conditions where synthetic municipal wastewater was used. Results show the satisfying overall performance of the CW units. Performance seems to be influenced by vegetation, temperature, and hydraulic residence time (HRT). The planted units produced better results than the unplanted one while, generally, all units operated better under warmer conditions. In addition, longer HRTs contributed to higher removal efficiencies. Finally, the systems showed higher removal efficiencies in the previous study (synthetic wastewater) regarding organic matter removal, while for the other pollutants, the present study (real wastewater) showed higher or comparable performance in most cases and especially in the planted units. The study also shows the overall good, continuous, and long-term operation of CW systems, since these systems operate for about 13 years.

Entities:  

Keywords:  Constructed wetlands; HRT; Horizontal subsurface flow; Natural systems; University campus wastewater; Vegetation

Mesh:

Substances:

Year:  2016        PMID: 27388592     DOI: 10.1007/s11356-016-7162-7

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  16 in total

1.  Comparison of interannual removal variation of various constructed wetland types.

Authors:  María Hijosa-Valsero; Ricardo Sidrach-Cardona; Eloy Bécares
Journal:  Sci Total Environ       Date:  2012-05-28       Impact factor: 7.963

2.  Constructed wetlands for wastewater and activated sludge treatment in north Greece: a review.

Authors:  V A Tsihrintzis; G D Gikas
Journal:  Water Sci Technol       Date:  2010       Impact factor: 1.915

3.  Environmental footprint of constructed wetlands treating wastewater.

Authors:  Dimitra Gkika; Georgios D Gikas; Vassilios A Tsihrintzis
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2015       Impact factor: 2.269

4.  Influence of the redox condition dynamics on the removal efficiency of a laboratory-scale constructed wetland.

Authors:  A Wiessner; U Kappelmeyer; P Kuschk; M Kästner
Journal:  Water Res       Date:  2005-01       Impact factor: 11.236

5.  Performance and cost comparison of a FWS and a VSF constructed wetland system.

Authors:  V A Tsihrintzis; C S Akratos; G D Gikas; D Karamouzis; A N Angelakis
Journal:  Environ Technol       Date:  2007-06       Impact factor: 3.247

6.  Reactive transport simulation in a tropical horizontal subsurface flow constructed wetland treating domestic wastewater.

Authors:  N Mburu; D P L Rousseau; J J A van Bruggen; G Thumbi; E Llorens; J García; P N L Lens
Journal:  Sci Total Environ       Date:  2013-02-26       Impact factor: 7.963

7.  Construction and operation costs of constructed wetlands treating wastewater.

Authors:  Dimitra Gkika; Georgios D Gikas; Vassilios A Tsihrintzis
Journal:  Water Sci Technol       Date:  2014       Impact factor: 1.915

Review 8.  Application of constructed wetlands for wastewater treatment in developing countries--a review of recent developments (2000-2013).

Authors:  Dong Qing Zhang; K B S N Jinadasa; Richard M Gersberg; Yu Liu; Wun Jern Ng; Soon Keat Tan
Journal:  J Environ Manage       Date:  2014-05-07       Impact factor: 6.789

9.  On-site treatment of domestic wastewater using a small-scale horizontal subsurface flow constructed wetland.

Authors:  G D Gikas; V A Tsihrintzis
Journal:  Water Sci Technol       Date:  2010       Impact factor: 1.915

10.  Evaluation of evapotranspiration in small on-site HSF constructed wetlands.

Authors:  Vassiliki A Papaevangelou; Georgios D Gikas; Vassilios A Tsihrintzis
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2012       Impact factor: 2.269

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.