Literature DB >> 21643509

Full Range Complex Spectral Domain Optical Coherence Tomography for Volumetric Imaging at 47, 000 A Scans per Second.

Lin An1, Molly Hrebesh, Ruikang K Wang.   

Abstract

In this paper, we demonstrate a high speed spectral domain optical coherence tomography (SDOCT) system capable of achieving full range complex imaging at 47 kHz line scan rate. By applying beam-offset method, a constant modulation frequency is introduced into each B-scan that enables reconstruction of the full range complex SDOCT images of in vivo tissue samples. To make use of the full capacity of detection camera used in the system, system control software is developed that streams the raw spectral fringe data directly into the computer memory. In order to assess performance of the high speed full range SDOCT system for imaging biological specimen, we present results imaged from the cuticle of fingernail of a human volunteer in vivo, and from the chicken embryos ex vivo. We also show the high sensitivity advantages of full range complex imaging as compared to the conventional SDOCT. To the best of our knowledge, 47,000 A-scan imaging rate is the highest imaging rate ever been reported for full range complex imaging. Notwithstanding, the method reported here has no limitations on the imaging speed, thus offers a useful tool to achieve volumetric imaging of living samples where the high sensitivity region around zero-delay line in the system can be utilized for imaging.

Entities:  

Year:  2010        PMID: 21643509      PMCID: PMC3104209          DOI: 10.1088/2040-8978/12/8/084003

Source DB:  PubMed          Journal:  J Opt        ISSN: 2040-8978            Impact factor:   2.516


  12 in total

1.  Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography.

Authors:  Yoshiaki Yasuno; Shuichi Makita; Takashi Endo; Gouki Aoki; Masahide Itoh; Toyohiko Yatagai
Journal:  Appl Opt       Date:  2006-03-10       Impact factor: 1.980

2.  Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography.

Authors:  Lin An; Ruikang K Wang
Journal:  Opt Lett       Date:  2007-12-01       Impact factor: 3.776

3.  Full range complex spectral optical coherence tomography technique in eye imaging.

Authors:  M Wojtkowski; A Kowalczyk; R Leitgeb; A F Fercher
Journal:  Opt Lett       Date:  2002-08-15       Impact factor: 3.776

4.  Fourier domain optical coherence tomography achieves full range complex imaging in vivo by introducing a carrier frequency during scanning.

Authors:  Ruikang K Wang
Journal:  Phys Med Biol       Date:  2007-09-14       Impact factor: 3.609

5.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography.

Authors:  Michael Choma; Marinko Sarunic; Changhuei Yang; Joseph Izatt
Journal:  Opt Express       Date:  2003-09-08       Impact factor: 3.894

6.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

7.  Retinal nerve fiber layer thickness map determined from optical coherence tomography images.

Authors:  Mircea Mujat; Raymond Chan; Barry Cense; B Park; Chulmin Joo; Taner Akkin; Teresa Chen; Johannes de Boer
Journal:  Opt Express       Date:  2005-11-14       Impact factor: 3.894

8.  Bidirectional Doppler Fourier-domain optical coherence tomography for measurement of absolute flow velocities in human retinal vessels.

Authors:  René M Werkmeister; Nikolaus Dragostinoff; Michael Pircher; Erich Götzinger; Christoph K Hitzenberger; Rainer A Leitgeb; Leopold Schmetterer
Journal:  Opt Lett       Date:  2008-12-15       Impact factor: 3.776

9.  "Coherence radar" and "spectral radar"-new tools for dermatological diagnosis.

Authors:  G Ha Usler; M W Lindner
Journal:  J Biomed Opt       Date:  1998-01       Impact factor: 3.170

10.  High speed full range complex spectral domain optical coherence tomography.

Authors:  Erich Götzinger; Michael Pircher; Rainer Leitgeb; Christoph Hitzenberger
Journal:  Opt Express       Date:  2005-01-24       Impact factor: 3.894

View more
  6 in total

Review 1.  Methods and algorithms for optical coherence tomography-based angiography: a review and comparison.

Authors:  Anqi Zhang; Qinqin Zhang; Chieh-Li Chen; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

2.  Rotational imaging optical coherence tomography for full-body mouse embryonic imaging.

Authors:  Chen Wu; Narendran Sudheendran; Manmohan Singh; Irina V Larina; Mary E Dickinson; Kirill V Larin
Journal:  J Biomed Opt       Date:  2016-02       Impact factor: 3.170

3.  Label-free optical lymphangiography: development of an automatic segmentation method applied to optical coherence tomography to visualize lymphatic vessels using Hessian filters.

Authors:  Siavash Yousefi; Jia Qin; Zhongwei Zhi; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

4.  High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

Authors:  Lin An; Guangying Guan; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

5.  Eigendecomposition-based clutter filtering technique for optical micro-angiography.

Authors:  Siavash Yousefi; Zhongwei Zhi; Ruikang K Wang
Journal:  IEEE Trans Biomed Eng       Date:  2011-05-12       Impact factor: 4.538

6.  Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCT.

Authors:  Kang Zhang; Jin U Kang
Journal:  Opt Express       Date:  2010-10-25       Impact factor: 3.894

  6 in total