Literature DB >> 21643121

Strehl ratios characterizing optical elements designed for presbyopia compensation.

K Petelczyc1, J Ares García, S Bará, Z Jaroszewicz, K Kakarenko, A Kolodziejczyk, M Sypek.   

Abstract

We present results of numerical analysis of the Strehl ratio characteristics for the light sword optical element (LSOE). For comparison there were analyzed other optical imaging elements proposed for compensation of presbyopia such as the bifocal lens, the trifocal lens, the stenopeic contact lens, and elements with extended depth of focus (EDOF), such as the logarithmic and quartic axicons. The simulations were based on a human eye's model being a simplified version of the Gullstrand model. The results obtained allow to state that the LSOE exhibits much more uniform characteristics of the Strehl ratio comparing with other known hitherto elements and therefore it could be a promising aid to compensate for the insufficient accommodation range of the human eye.

Entities:  

Mesh:

Year:  2011        PMID: 21643121     DOI: 10.1364/OE.19.008693

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  Assessment of imaging with extended depth-of-field by means of the light sword lens in terms of visual acuity scale.

Authors:  Karol Kakarenko; Izabela Ducin; Krzysztof Grabowiecki; Zbigniew Jaroszewicz; Andrzej Kolodziejczyk; Alejandro Mira-Agudelo; Krzysztof Petelczyc; Aleksandra Składowska; Maciej Sypek
Journal:  Biomed Opt Express       Date:  2015-04-16       Impact factor: 3.732

2.  Model of the light sword intraocular lens: in-vitro comparative studies.

Authors:  Krzysztof Petelczyc; Andrzej Kolodziejczyk; Narcyz Błocki; Anna Byszewska; Zbigniew Jaroszewicz; Karol Kakarenko; Katarzyna Kołacz; Michał Miler; Alejandro Mira-Agudelo; Walter Torres-Sepúlveda; Marek Rękas
Journal:  Biomed Opt Express       Date:  2019-12-04       Impact factor: 3.732

3.  Impact of contact lens zone geometry and ocular optics on bifocal retinal image quality.

Authors:  Arthur Bradley; Jayoung Nam; Renfeng Xu; Leslie Harman; Larry Thibos
Journal:  Ophthalmic Physiol Opt       Date:  2014-03-04       Impact factor: 3.117

4.  The Light Sword Lens - A novel method of presbyopia compensation: Pilot clinical study.

Authors:  Krzysztof Petelczyc; Anna Byszewska; Ewelina Chojnacka; Zbigniew Jaroszewicz; Karol Kakarenko; Alejandro Mira-Agudelo; Aleksandra Ostrowska-Spaleniak; Aleksandra Składowska; Andrzej Kołodziejczyk; Marek Rękas
Journal:  PLoS One       Date:  2019-02-04       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.