Literature DB >> 21641569

Cardiopulmonary limited ultrasound examination for "quick-look" bedside application.

Bruce J Kimura1, Norihiro Yogo, Charles W O'Connell, James N Phan, Brian K Showalter, Tanya Wolfson.   

Abstract

Although taking a "quick look" at the heart using a small ultrasound device is now feasible, a formal ultrasound imaging protocol to augment the bedside physical examination has not been developed. Therefore, we sought to evaluate the diagnostic accuracy and prognostic value of a cardiopulmonary limited ultrasound examination (CLUE) using 4 simplified diagnostic criteria that would screen for left ventricular dysfunction (LV), left atrial (LA) enlargement, inferior vena cava plethora (IVC+), and ultrasound lung comet-tail artifacts (ULC+) in patients referred for echocardiography. The CLUE was tested by interpretation of only the parasternal LV long-axis, subcostal IVC, and 2 lung apical views in each of 1,016 consecutive echocardiograms performed with apical lung imaging. For inpatients, univariate and multivariate logistic regression analyses were performed to assess the relations between mortality, CLUE findings, age, and gender. In this echocardiographic referral series, 78% (n = 792) were inpatient and 22% (n = 224) were outpatient. The CLUE criteria demonstrated a sensitivity, specificity, and accuracy for a LV ejection fraction of ≤40% of 69%, 91%, and 89% and for LA enlargement of 75%, 72%, and 73%, respectively. CLUE findings of LV dysfunction, LA enlargement, IVC+, and ULC+ were seen in 16%, 53%, 34%, and 28% of inpatients. The best multivariate logistic model contained 3 predictors of in-hospital mortality: ULC+, IVC+ and male gender, with adjusted odds ratios (95% confidence intervals) of 3.5 (1.4 to 8.8), 5.8 (2.1 to 16.4), and 2.3 (0.9 to 5.8), respectively. In conclusion, a CLUE consisting of 4 quick-look "signs" has reasonable diagnostic accuracy for bedside use and contains prognostic information.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21641569     DOI: 10.1016/j.amjcard.2011.03.091

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  25 in total

1.  New Views: Handheld Ultrasound at the Bedside.

Authors:  Colin T Phillips
Journal:  J Grad Med Educ       Date:  2015-06

Review 2.  Point-of-care ultrasound education to improve care of dialysis patients.

Authors:  Surekha Mullangi; Stephen M Sozio; Paul Segal; Steven Menez; Carol Martire; Tariq Shafi
Journal:  Semin Dial       Date:  2018-01-03       Impact factor: 3.455

Review 3.  Focused cardiac and lung ultrasonography: implications and applicability in the perioperative period.

Authors:  José L Díaz-Gómez; Gabriele Via; Harish Ramakrishna
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

Review 4.  Focused critical care echocardiography.

Authors:  Achikam Oren-Grinberg; Daniel Talmor; Samuel M Brown
Journal:  Crit Care Med       Date:  2013-11       Impact factor: 7.598

5.  Detection and prognostic value of pulmonary congestion by lung ultrasound in ambulatory heart failure patients.

Authors:  Elke Platz; Eldrin F Lewis; Hajime Uno; Julie Peck; Emanuele Pivetta; Allison A Merz; Dorothea Hempel; Christina Wilson; Sarah E Frasure; Pardeep S Jhund; Susan Cheng; Scott D Solomon
Journal:  Eur Heart J       Date:  2016-01-26       Impact factor: 29.983

6.  Expert consensus statement 'Neonatologist-performed Echocardiography (NoPE)'-training and accreditation in UK.

Authors:  Yogen Singh; Samir Gupta; Alan M Groves; Anjum Gandhi; John Thomson; Shakeel Qureshi; John M Simpson
Journal:  Eur J Pediatr       Date:  2015-09-12       Impact factor: 3.183

7.  The diagnosis of right heart thrombus by focused cardiac ultrasound in a critically ill patient in compensated shock.

Authors:  Mansour Jammal; Peter Milano; Renzo Cardenas; Thomas Mailhot; Diku Mandavia; Phillips Perera
Journal:  Crit Ultrasound J       Date:  2015-05-13

8.  Feasibility of remote real-time guidance of a cardiac examination performed by novices using a pocket-sized ultrasound device.

Authors:  Tuan V Mai; David T Ahn; Colin T Phillips; Donna L Agan; Bruce J Kimura
Journal:  Emerg Med Int       Date:  2013-08-20       Impact factor: 1.112

9.  Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants.

Authors:  Benjamim Ficial; Anna E Finnemore; David J Cox; Kathryn M Broadhouse; Anthony N Price; Giuliana Durighel; Georgia Ekitzidou; Joseph V Hajnal; A David Edwards; Alan M Groves
Journal:  J Am Soc Echocardiogr       Date:  2013-09-26       Impact factor: 5.251

10.  Rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating heart failure from pulmonary disease as the cause of acute dyspnea in the emergency setting.

Authors:  Katsuya Kajimoto; Keiko Madeen; Tomoko Nakayama; Hiroki Tsudo; Tadahide Kuroda; Takashi Abe
Journal:  Cardiovasc Ultrasound       Date:  2012-12-04       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.