Histologic evaluation of root-surface healing after root contact or approximation during placement of mini-implants.

Hyewon Kim1, Tae-Woo Kim.   

Abstract

INTRODUCTION: Placement of mini-implants carries with it the risk of iatrogenic damage to the adjacent root surfaces. The aims of this study were to assess the type of trauma incurred on tooth roots after contact or approximation with mini-implants during placement, and to observe and analyze the healing responses via histologic analysis.
METHODS: Four male minipigs were used as experimental subjects. Twenty mini-implants (1.6 × 8 mm) were implanted in each minipig into the buccal sides of all 4 quadrants between the roots of teeth so that contact or approximation between the mini-implant and root surface occurred, with the aid of dental fluoroscopy. All mini-implants on the left side of the mouth were left in situ, and all mini-implants on the right side were removed immediately after placement. The minipigs were killed at 4-week intervals up to week 16, and histologic sections were made.
RESULTS: When mini-implants were left in situ, the root surface was mostly resorbed away from the mini-implant thread. Partial repair started at 8 weeks. When the mini-implant thread was left touching the root, there was no normal healing response. If the mini-implant was placed less than 1 mm from the periodontal ligament, resorption was evident on the root surface. Abnormal healing responses were seen when the pulp tissue was ruptured, mostly through osteodentin formation. In all instances after mini-implant removal immediately after placement, varying degrees of cementum repair was observed.
CONCLUSIONS: Immediate removal of the mini-implant leads to cementum repair, whereas leaving the mini-implant in place will cause either a delay in repair or no repair. Placing mini-implants less than 1 mm from the root surface causes root-surface resorption.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21640881     DOI: 10.1016/j.ajodo.2009.06.042

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Effect of loaded orthodontic miniscrew implant on compressive stresses in adjacent periodontal ligament.

Authors:  Mhd Hassan Albogha; Ichiro Takahashi
Journal:  Angle Orthod       Date:  2018-09-19       Impact factor: 2.079

2.  Dentointegration of a titanium implant: a case report.

Authors:  Frank Schwarz; Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker
Journal:  Oral Maxillofac Surg       Date:  2012-11-30

3.  Assessment of damping capacity as an index of root proximity in self-drilling orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Yasuki Uchida; Miho Matsuoka; Mizuki Inaba; Hiroaki Iwai; Yoko Karasawa; Noriyoshi Shimizu
Journal:  Clin Oral Investig       Date:  2013-03-22       Impact factor: 3.573

4.  Photobiomodulation stimulates surrounding bone formation and increases stability of titanium alloy miniscrews in ovariectomized rats.

Authors:  Bruna Guimarães Martins; Vanessa Santos de Moura; Denise Nami Fujii; Aguinaldo Silva Garcez; Selly Sayuri Suzuki
Journal:  Lasers Med Sci       Date:  2022-04-14       Impact factor: 2.555

5.  Tomographic evaluation of infrazygomatic crest for orthodontic anchorage in different vertical and sagittal skeletal patterns.

Authors:  Alana Tavares; Iêda-Margarida Crusoé-Rebello; Frederico-Sampaio Neves
Journal:  J Clin Exp Dent       Date:  2020-11-01

6.  Effects of orthodontic force on root surface damage caused by contact with temporary anchorage devices and on the repair process.

Authors:  Özge Çelik Güler; Sıddık Malkoç
Journal:  Korean J Orthod       Date:  2019-03-19       Impact factor: 1.372

7.  Reader's Forum.

Authors:  Sun Mi Kwon
Journal:  Korean J Orthod       Date:  2018-12-19       Impact factor: 1.372

8.  Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion.

Authors:  Il-Sik Cho; Tae-Woo Kim; Sug-Joon Ahn; Il-Hyung Yang; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

9.  Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.

Authors:  Hyun-Ju Oh; Jung-Yul Cha; Hyung-Seog Yu; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

10.  Root repair after damage due to screw insertion for orthodontic miniplate placement.

Authors:  Marie A Cornelis; Michele Tepedino; Paolo M Cattaneo; Catherine Nyssen-Behets
Journal:  J Clin Exp Dent       Date:  2019-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.