Literature DB >> 21639278

Anodic stripping voltammetry coupled on-line with inductively coupled plasma mass spectrometry:  optimization of a thin-layer flow cell system for analyte signal enhancement.

J R Pretty1, D C Duckworth, G J Van Berkel.   

Abstract

Parameters affecting analyte signal enhancement in anodic stripping voltammetry-inductively coupled plasma mass spectrometry (ASV-ICP-MS), using a thin-layer ASV cell and microconcentric nebulization (MCN), have been examined. Silver was used as a test analyte and was deposited at a glassy carbon working electrode. The MCN allowed use of solution flow rates that were beneficial to optimum electrolytic performance of the thin-layer cell. High analyte deposition efficiencies obtained with the thin-layer cell, combined with minimal sample consumption of the MCN, allowed substantial signal enhancement (>400 times higher than continuous nebulization level) to be obtained with 2-3 mL of sample and deposition times of less than 30 min. Signal enhancement was strongly influenced by the opposing effect of flow rate on the electrolytic deposition efficiency (deposition efficiency decreases with increasing flow rate) and on the quantity of analyte delivered to the cell (analyte mass throughput increases with increasing flow rate). Excellent linearity for stripping peak heights was demonstrated for a wide range of analyte deposition times and for peak heights and peak areas (r > 0.999) over a wide concentration range (25 ng/L-20 μg/L). Precision was good (RSD typically <3% for n = 3-6) except for a high Ag blank contributed to by corrosion of the counter electrode and by Ag diffusion from the reference electrode into the cell. Details of the flow manifold and ASV cells are discussed, along with relevant performance characteristics of the MCN.

Entities:  

Year:  1997        PMID: 21639278     DOI: 10.1021/ac970360d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Nafion-coated bismuth film and nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry.

Authors:  Grace X Cao; Omar Jimenez; Feimeng Zhou; Maotian Xu
Journal:  J Am Soc Mass Spectrom       Date:  2006-05-15       Impact factor: 3.109

2.  Electrochemical sample matrix elimination for trace-level potentiometric detection with polymeric membrane ion-selective electrodes.

Authors:  Karin Y Chumbimuni-Torres; Percy Calvo-Marzal; Joseph Wang; Eric Bakker
Journal:  Anal Chem       Date:  2008-06-21       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.