Literature DB >> 16698277

Nafion-coated bismuth film and nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry.

Grace X Cao1, Omar Jimenez1, Feimeng Zhou2, Maotian Xu3.   

Abstract

Nafion-coated bismuth film electrodes (NCBFEs) and Nafion-coated mercury film electrodes (NCMFEs) were used to electrochemically preconcentrate metal analytes for subsequent analysis by inductively coupled plasma-mass spectrometry (ICP-MS). Either type of electrodes is part of a thin-layer electrochemical flow cell that is positioned upstream of a microconcentric nebulizer for the ICP-MS. Performances of these electrodes were compared in terms of the analytical "figures of merit" (e.g., dynamic ranges, reproducibility, hydrodynamic stability, and elimination of matrix effects detrimental to ICP-MS). The coupled technique (ASV-ICP-MS) is found to possess a wide dynamic range (at least 4 to 5 orders of magnitude) and to be reproducible. Both electrodes are much more stable than the thin mercury film electrode (TMFE) traditionally used for ASV-ICP-MS, with the lifetime of the NCBFE exceeding 8 h. Adopting these electrodes for ASV-ICP-MS overcomes the problems associated with a TMFE, the erosion of which decreases the sample throughput, affects the analysis precision, and contaminates conventional glass nebulizers and spray chambers of the spectrometer. The medium exchange procedure inherent in ASV is successfully implemented with a two-valve flow injection system for the accumulation of trace Cd2+ into the electrode from a certified seawater sample, followed by stripping Cd into a solution that is compatible to the ICP-MS operation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16698277     DOI: 10.1016/j.jasms.2006.03.001

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  12 in total

1.  Anodic stripping voltammetry combined on-line with inductively coupled plasma-MS via a direct-injection high-efficiency nebulizer.

Authors:  Alfred J Baca; Ana B De la Ree; Feimeng Zhou; Andrew Z Mason
Journal:  Anal Chem       Date:  2003-05-15       Impact factor: 6.986

Review 2.  Electrochemistry/mass spectrometry (EC/MS)--a new tool to study drug metabolism and reaction mechanisms.

Authors:  Uwe Karst
Journal:  Angew Chem Int Ed Engl       Date:  2004-05-03       Impact factor: 15.336

3.  A study of Nafion-coated bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry.

Authors:  Georgia Kefala; Anastasios Economou; Anastasios Voulgaropoulos
Journal:  Analyst       Date:  2004-09-03       Impact factor: 4.616

4.  Anodic stripping voltammetry coupled on-line with inductively coupled plasma mass spectrometry:  optimization of a thin-layer flow cell system for analyte signal enhancement.

Authors:  J R Pretty; D C Duckworth; G J Van Berkel
Journal:  Anal Chem       Date:  1997-09-01       Impact factor: 6.986

5.  Application of polymer-coated glassy carbon electrodes to the direct determination of trace metals in body fluids by anodic stripping voltammetry.

Authors:  B Hoyer; T M Florence
Journal:  Anal Chem       Date:  1987-12-15       Impact factor: 6.986

6.  Mercury film electrodes: developments, trends and potentialities for electroanalysis.

Authors:  A Economou; P R Fielden
Journal:  Analyst       Date:  2003-03       Impact factor: 4.616

7.  Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes.

Authors:  Craig E Banks; Jaanus Kruusma; Michael E Hyde; Abdollah Salimi; Richard G Compton
Journal:  Anal Bioanal Chem       Date:  2004-04-08       Impact factor: 4.142

8.  On-line electrochemistry/thermospray/tandem mass spectrometry as a new approach to the study of redox reactions: the oxidation of uric acid.

Authors:  K J Volk; R A Yost; A Brajter-Toth
Journal:  Anal Chem       Date:  1989-08-01       Impact factor: 6.986

9.  Signal stability of Nafion-coated thin mercury film electrodes for stripping voltammetry.

Authors:  B Hoyer; N Jensen
Journal:  Talanta       Date:  1994-03       Impact factor: 6.057

10.  A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair.

Authors:  G Kefala; A Economou; A Voulgaropoulos; M Sofoniou
Journal:  Talanta       Date:  2003-12-04       Impact factor: 6.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.