Literature DB >> 21637125

Calculating the mounting parameters for Taylor Spatial Frame correction using computed tomography.

Metin Kucukkaya1, Ozgur Karakoyun, Raffi Armagan, Unal Kuzgun.   

Abstract

The Taylor Spatial Frame uses a computer program-based six-axis deformity analysis. However, there is often a residual deformity after the initial correction, especially in deformities with a rotational component. This problem can be resolved by recalculating the parameters and inputting all new deformity and mounting parameters. However, this may necessitate repeated x-rays and delay treatment. We believe that error in the mounting parameters is the main reason for most residual deformities. To prevent these problems, we describe a new calculation technique for determining the mounting parameters that uses computed tomography. This technique is especially advantageous for deformities with a rotational component. Using this technique, exact calculation of the mounting parameters is possible and the residual deformity and number of repeated x-rays can be minimized. This new technique is an alternative method to accurately calculating the mounting parameters.

Entities:  

Mesh:

Year:  2011        PMID: 21637125     DOI: 10.1097/BOT.0b013e3181ee40c5

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  10 in total

1.  [Correction of posttraumatic lower leg deformities using the Taylor Spatial Frame].

Authors:  D Krappinger; M Zegg; V Smekal; B Huber
Journal:  Oper Orthop Traumatol       Date:  2014-10       Impact factor: 1.154

2.  Distance from the magnification device contributes to differences in lower leg length measured in patients with TSF correction.

Authors:  Marc-Daniel Ahrend; Michael Rühle; Fabian Springer; Heiko Baumgartner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-06       Impact factor: 2.928

3.  The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator.

Authors:  Jonathan Wright; Shiraz A Sabah; Shelain Patel; Gavin Spence
Journal:  Strategies Trauma Limb Reconstr       Date:  2017-05-12

4.  Improving postoperative radiographs for the parameter measurement of hexapod external fixator using an additional foot ring.

Authors:  Yanshi Liu; Kai Liu; Feiyu Cai; Tao Zhang; Aihemaitijiang Yusufu
Journal:  J Orthop Surg Res       Date:  2021-11-13       Impact factor: 2.359

5.  Opening Wedge High Tibial Osteotomy with Combined Use of Patient-Specific 3D-Printed Plates and Taylor Spatial Frame for the Treatment of Knee Osteoarthritis.

Authors:  Desheng Duan; Yang Cao; Renzeng Li; Guohui Wang; Yongfei Zhang; Kui Xiang; Yanli Hu; Yiqun Li; Peng Peng; Pan Zhang; Xianzhe Liu
Journal:  Pain Res Manag       Date:  2021-12-01       Impact factor: 3.037

6.  Marker- three dimensional measurement versus traditional radiographic measurement in the treatment of tibial fracture using Taylor spatial frame.

Authors:  Qixin Liu; Yanshi Liu; Hong Li; Xuefei Fu; Xingpeng Zhang; Sida Liu; Jinli Zhang; Tao Zhang
Journal:  BMC Musculoskelet Disord       Date:  2022-02-16       Impact factor: 2.362

7.  Staged correction trajectory with hexapod external fixator for the satisfactory reduction of long bone shaft fracture.

Authors:  Yanshi Liu; Fei Wang; Kai Liu; Feiyu Cai; Xingpeng Zhang; Hong Li; Tao Zhang; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2022-03-08       Impact factor: 2.362

8.  Hospitalization for computer-assisted hexapod ring fixation application - analyses of patient variability, peri-operative complications, hospital costs, and discharge status.

Authors:  J Spence Reid; Mollie Vanderkarr; Bidusee Ray; Abhishek Chitnis; Chantal E Holy; Charisse Sparks
Journal:  BMC Musculoskelet Disord       Date:  2022-03-05       Impact factor: 2.362

9.  Treatment of open fractures with a computer-assisted external fixator system without the use of fluoroscopy.

Authors:  Adnan Kara; Haluk Celik; Ali Seker; Ozgur Karakoyun; Raffi Armagan; Ersin Kuyucu; Mehmet Erdil
Journal:  J Orthop Surg Res       Date:  2016-04-26       Impact factor: 2.359

10.  Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.

Authors:  Yanshi Liu; Hong Li; Jialin Liu; Xingpeng Zhang; Maimaiaili Yushan; Zhenhui Liu; Chuang Ma; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-24       Impact factor: 2.362

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.