Literature DB >> 21636149

Quality of life improvement at midterm follow-up after transcatheter aortic valve implantation.

Alexandra Gonçalves1, Pedro Marcos-Alberca, Carlos Almeria, Gisela Feltes, Rosa Ana Hernández-Antolín, Enrique Rodríguez, José Luis Rodrigo, Javier Cobiella, Luis Maroto, José C Silva Cardoso, Carlos Macaya, José Luis Zamorano.   

Abstract

BACKGROUND: Transcatheter aortic valve implantation (TAVI) techniques have been presenting good procedural success and favorable clinical outcomes. However, optimal management of aortic valve disease in elderly patients depends on quality of life (QoL) improvement. In this study we aimed to evaluate changes in QoL in patients referred for TAVI. METHODS AND
RESULTS: Prospective analysis of 74 consecutive patients (34 male), aged 81.6 ± 8 years with symptomatic severe aortic valve stenosis (AS) ineligible for conventional aortic valve replacement, referred to TAVI in one tertiary center. For the assessment of QoL, the Minnesota Living with Heart Failure Questionnaire (MLHFQ) was used before the procedure and at 6.5 months. The mortality was 9.5% at 30 days and 20.2% at 6.5 months follow-up. Fifty three (71.6%) patients completed MLHFQ at baseline and at follow-up. All patients showed good hemodynamic results and no signs of prosthesis dysfunction were observed on transthoracic echocardiography. The New York Heart Association (NYHA) class (2.9 ± 0.4 to 1.4 ± 0.7; p<0.001), and the MLHFQ scores [overall (37.0 ± 14.7 vs. 14.4 ± 10.1; p<0.001), physical dimension (23.2 ± 9.5 vs. 8.6 ± 5.9; p<0.001) and emotional dimension (5.4 ± 4.2 vs. 2.6 ± 3.0; p<0.001)] were significantly improved 6.5 months after TAVI. Patients with peripheral vascular disease (PVD) had an inferior improvement in QoL caused by a lower enhancement in physical dimension MLHFQ score (mean difference: -17.0 ± 10.2 vs. -10.1 ± 11.5; p=0.036).
CONCLUSION: TAVI significantly improves symptoms and QoL in patients with severe AS and high surgical risk. Patients with PVD might be expected to have a less impressive improvement in QoL after TAVI.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21636149     DOI: 10.1016/j.ijcard.2011.05.050

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  12 in total

Review 1.  TAVI 2012: state of the art.

Authors:  Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

2.  In vivo tissue engineering of a trilayered leaflet-shaped tissue construct.

Authors:  Soumen Jana; Amir Lerman
Journal:  Regen Med       Date:  2020-02-26       Impact factor: 3.806

3.  Predictors of length of stay and duration of tracheal intubation after transcatheter aortic valve implantation.

Authors:  Vasileios Patris; Konstantinos Giakoumidakis; Mihalis Argiriou; Katerina K Naka; Efstratios Apostolakis; Mark Field; Manoj Kuduvalli; Aung Oo; Stavros Siminelakis
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

Review 4.  Transcatheter aortic valve implantation: current and future approaches.

Authors:  Josep Rodés-Cabau
Journal:  Nat Rev Cardiol       Date:  2011-11-15       Impact factor: 32.419

Review 5.  New conduction abnormalities after TAVI--frequency and causes.

Authors:  Robert M van der Boon; Rutger-Jan Nuis; Nicolas M Van Mieghem; Luc Jordaens; Josep Rodés-Cabau; Ron T van Domburg; Patrick W Serruys; Robert H Anderson; Peter P T de Jaegere
Journal:  Nat Rev Cardiol       Date:  2012-05-01       Impact factor: 32.419

6.  The First Case of Successful Transcatheter Aortic Valve Implantation Using CoreValve in Korea.

Authors:  In-Soo Kim; Young-Guk Ko; Sanghoon Shin; Ji-Young Shim; Sak Lee; Byung-Chul Chang; Jae-Kwang Shim; Young-Ran Kwak; Myeong-Ki Hong
Journal:  Korean Circ J       Date:  2012-11-28       Impact factor: 3.243

Review 7.  Beyond adding years to life: health-related quality-of-life and functional outcomes in patients with severe aortic valve stenosis at high surgical risk undergoing transcatheter aortic valve replacement.

Authors:  Marcus-Andre Deutsch; Sabine Bleiziffer; Yacine Elhmidi; Nicolo Piazza; Bernhard Voss; Ruediger Lange; Markus Krane
Journal:  Curr Cardiol Rev       Date:  2013-11

8.  Change in quality of life after transcatheter aortic valve implantation and aortic valve replacement surgery in Australian patients aged ≥ 75 years: the effects of EuroSCORE and patient operability.

Authors:  Phillip J Tully; Prakash Roshan; Greg D Rice; Ajay Sinhal; Jayme S Bennetts; Robert A Baker
Journal:  J Geriatr Cardiol       Date:  2015-01       Impact factor: 3.327

Review 9.  Functional status and quality of life after transcatheter aortic valve replacement: a systematic review.

Authors:  Caroline A Kim; Suraj P Rasania; Jonathan Afilalo; Jeffrey J Popma; Lewis A Lipsitz; Dae Hyun Kim
Journal:  Ann Intern Med       Date:  2014-02-18       Impact factor: 25.391

10.  Comparison of Transcatheter Aortic Valve Implantation versus Surgical Aortic Valve Replacement to Improve Quality of Life in Patients >70 Years of Age with Severe Aortic Stenosis.

Authors:  Cemal Kocaaslan; Bülend Ketenci; Mehmet Yılmaz; Tamer Kehlibar; Mehmet Erdem Memetoğlu; Gökhan Ertaş; Mehmet Eren; Mahmut Murat Demirtaş
Journal:  Braz J Cardiovasc Surg       Date:  2016-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.