Closed circuit MR compatible pulsatile pump system using a ventricular assist device and pressure control unit.

R Lorenz1, C Benk, J Bock, A F Stalder, J G Korvink, J Hennig, M Markl.   

Abstract

The aim of this study was to evaluate the performance of a closed circuit MR compatible pneumatically driven pump system using a ventricular assist device as pulsatile flow pump for in vitro 3D flow simulation. Additionally, a pressure control unit was integrated into the flow circuit. The performance of the pump system and its test-retest reliability was evaluated using a stenosis phantom (60% lumen narrowing). Bland-Altman analysis revealed a good test-retest reliability (mean differences = -0.016 m/s, limits of agreement = ±0.047 m/s) for in vitro flow measurements. Furthermore, a rapid prototyping in vitro model of a normal thoracic aorta was integrated into the flow circuit for a direct comparison of flow characteristics with in vivo data in the same subject. The pneumatically driven ventricular assist device was attached to the ascending aorta of the in vitro model to simulate the beating left ventricle. In the descending part of the healthy aorta a flexible stenosis was integrated to model an aortic coarctation. In vivo and in vitro comparison showed significant (P = 0.002) correlations (r = 0.9) of mean velocities. The simulation of increasing coarctation grade led to expected changes in the flow patterns such as jet flow in the post-stenotic region and increased velocities.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21630351     DOI: 10.1002/mrm.22983

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

Authors:  Emilie Bollache; Alex J Barker; Ryan Scott Dolan; James C Carr; Pim van Ooij; Rouzbeh Ahmadian; Alex Powell; Jeremy D Collins; Julia Geiger; Michael Markl
Journal:  Magn Reson Med       Date:  2017-03-07       Impact factor: 4.668

2.  Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Hyungkyu Huh; Christoph Forman; Alireza Vali; Andreas Greiser; James Carr; Susanne Schnell; Alex J Barker; Ning Jin
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

3.  Efficient triple-VENC phase-contrast MRI for improved velocity dynamic range.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Alireza Vali; Can Wu; Susanne Schnell
Journal:  Magn Reson Med       Date:  2019-08-18       Impact factor: 4.668

4.  Evaluation of aortic stenosis severity using 4D flow jet shear layer detection for the measurement of valve effective orifice area.

Authors:  Julio Garcia; Michael Markl; Susanne Schnell; Bradley Allen; Pegah Entezari; Riti Mahadevia; S Chris Malaisrie; Philippe Pibarot; James Carr; Alex J Barker
Journal:  Magn Reson Imaging       Date:  2014-04-24       Impact factor: 2.546

5.  Highly accelerated, real-time phase-contrast MRI using radial k-space sampling and GROG-GRASP reconstruction: a feasibility study in pediatric patients with congenital heart disease.

Authors:  Hassan Haji-Valizadeh; Li Feng; Liliana E Ma; Daming Shen; Kai Tobias Block; Joshua D Robinson; Michael Markl; Cynthia K Rigsby; Daniel Kim
Journal:  NMR Biomed       Date:  2020-01-24       Impact factor: 4.044

6.  5D Flow MRI: A Fully Self-gated, Free-running Framework for Cardiac and Respiratory Motion-resolved 3D Hemodynamics.

Authors:  Liliana E Ma; Jérôme Yerly; Davide Piccini; Lorenzo Di Sopra; Christopher W Roy; James C Carr; Cynthia K Rigsby; Daniel Kim; Matthias Stuber; Michael Markl
Journal:  Radiol Cardiothorac Imaging       Date:  2020-11-12

7.  On the impact of vessel wall stiffness on quantitative flow dynamics in a synthetic model of the thoracic aorta.

Authors:  Judith Zimmermann; Michael Loecher; Fikunwa O Kolawole; Kathrin Bäumler; Kyle Gifford; Seraina A Dual; Marc Levenston; Alison L Marsden; Daniel B Ennis
Journal:  Sci Rep       Date:  2021-03-23       Impact factor: 4.379

8.  Hemodynamic evaluation in patients with transposition of the great arteries after the arterial switch operation: 4D flow and 2D phase contrast cardiovascular magnetic resonance compared with Doppler echocardiography.

Authors:  Kelly Jarvis; Marleen Vonder; Alex J Barker; Susanne Schnell; Michael Rose; James Carr; Joshua D Robinson; Michael Markl; Cynthia K Rigsby
Journal:  J Cardiovasc Magn Reson       Date:  2016-09-22       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.