Literature DB >> 21627693

Fate of a modified fenestration of atrial septal occluder device after transcatheter closure of atrial septal defects in elderly patients.

Heike E Schneider1, Christian Jux, Thomas Kriebel, Thomas Paul.   

Abstract

BACKGROUND: Data on closure of atrial septal defects (ASD) in elderly patients with a fenestrated Amplatzer septal occluder (ASO) device is limited.
METHODS: A hemodynamically significant ASD was closed with a fenestrated ASO in 3 patients with ages >62 years. Prior to implant a 4-mm fenestration was created by balloon dilatation without additional suture fixation just adjacent to the stent part of the device. Indications for fenestration were restrictive left ventricular physiology and/or pulmonary hypertension. Heparin had been administered during and for 48 hours after the procedure. Two patients were maintained on phenprocoumon because of chronic atrial fibrillation, the remaining patient on aspirin and clopidogrel for 3 months after implant. Transesophageal echocardiography (TEE) and hemodynamic evaluation were performed 4-18 months after ASD closure.
RESULTS: A trace or small fenestration through the ASO with left-to-right shunt was detected by TEE in all 3 patients without any hemodynamic significance. No thrombus formation was observed. Pulmonary hypertension improved in the affected patient. Pulmonary arterial wedge pressure and cardiac index improved in the second patient with improvement in heart failure symptoms and of quality of life in both. The third patient, after initial improvement for 6 months, developed significant comorbidities and clinical deterioration at 18 months follow-up.
CONCLUSION: The modified fenestration of the ASO decreased significantly in size at follow-up. Applying this technique to selected patients judged to be at risk for ASD closure avoids acute decompensation and allows gradual diminuition of right ventricular volume overload during mid-term follow-up. ©2011, Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21627693     DOI: 10.1111/j.1540-8183.2011.00653.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  3 in total

1.  Atrial Septal Defect Closure with Occlutech® ASD Fenestrated Device in a Child with Severe Pulmonary Hypertension.

Authors:  Francisco Gonzalez-Barlatay; Anne Fournier; Marie-Josée Raboisson; Nagib Dahdah
Journal:  Pediatr Cardiol       Date:  2016-11-21       Impact factor: 1.655

Review 2.  Interventional cardiology in adults with congenital heart disease.

Authors:  Harsimran S Singh; Eric Horlick; Mark Osten; Lee N Benson
Journal:  Nat Rev Cardiol       Date:  2013-08-27       Impact factor: 32.419

3.  Percutaneous closure of residual shunting in a patient with a fenestrated atrial septal defect occluder: A case report.

Authors:  Wang Man; Ma Xinxin; Zhang Yueli; Li Feng
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.