Immediate loading of mandibular overdentures supported by unsplinted direct laser metal-forming implants: results from a 1-year prospective study.

Carlo Mangano1, Francesco G Mangano, Jamil A Shibli, Massimiliano Ricci, Vittoria Perrotti, Susana d'Avila, Adriano Piattelli.   

Abstract

BACKGROUND: At present, only some studies have dealt with immediate loading of unsplinted implants supporting mandibular overdentures. The aim of this prospective study is to evaluate treatment outcomes of mandibular overdentures supported by four one-piece, unsplinted, immediately loaded, direct laser metal-forming (DLMF) implants by assessing implant survival rate, implant success, marginal bone loss, and prosthetic complications.
METHODS: A total of 96 one-piece DLMF implants were inserted in the edentulous mandible of 24 patients. Four implants were placed in each edentulous mandible. Immediately after implant placement, a mandibular overdenture was connected to the implants. At 1-year follow-up, clinical, radiographic, and prosthetic parameters were assessed. Success criteria included absence of pain, suppuration, and implant mobility; absence of continuous peri-implant radiolucency; and distance between the implant shoulder and the first visible bone contact <1.5 mm.
RESULTS: After a 1-year loading time, the overall implant survival rate was 98.9%, with only one implant lost. Among the surviving 95 implants, two did not fulfill the success criteria; therefore, the implant success rate was 97.8%. The mean distance between the implant shoulder and the first visible bone contact was 0.28 ± 0.30 mm (95% confidence interval, 0.24 to 0.32). Some prosthetic complications were reported.
CONCLUSION: Based on the present results and within the limits of this study, the immediate loading of four unsplinted DLMF implants by means of ball attachment-supported mandibular overdentures seems to represent a safe and successful procedure.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21627459     DOI: 10.1902/jop.2011.110079

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  10 in total

1.  Custom-made, root-analogue direct laser metal forming implant: a case report.

Authors:  Francesco Guido Mangano; Bruno Cirotti; Rachel Lilian Sammons; Carlo Mangano
Journal:  Lasers Med Sci       Date:  2012-06-15       Impact factor: 3.161

Review 2.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

3.  Custom-made, selective laser sintering (SLS) blade implants as a non-conventional solution for the prosthetic rehabilitation of extremely atrophied posterior mandible.

Authors:  F Mangano; M Bazzoli; L Tettamanti; D Farronato; M Maineri; A Macchi; C Mangano
Journal:  Lasers Med Sci       Date:  2012-09-14       Impact factor: 3.161

4.  Immediate, non-submerged, root-analogue direct laser metal sintering (DLMS) implants: a 1-year prospective study on 15 patients.

Authors:  Francesco Guido Mangano; Michele De Franco; Alberto Caprioglio; Aldo Macchi; Adriano Piattelli; Carlo Mangano
Journal:  Lasers Med Sci       Date:  2013-03-15       Impact factor: 3.161

5.  Immediate loading of implants in the edentulous mandible: a multicentre study.

Authors:  Paulo Esteves Pinto Faria; Bárbara Masalskas; Anders Heyden; Lars Rasmusson; Luiz Antonio Salata
Journal:  Oral Maxillofac Surg       Date:  2016-09-16

Review 6.  Additive manufacturing technique-designed metallic porous implants for clinical application in orthopedics.

Authors:  Chaohua Gao; Chenyu Wang; Hui Jin; Zhonghan Wang; Zuhao Li; Chenyu Shi; Yi Leng; Fan Yang; He Liu; Jincheng Wang
Journal:  RSC Adv       Date:  2018-07-16       Impact factor: 4.036

Review 7.  Direct metal laser sintering titanium dental implants: a review of the current literature.

Authors:  F Mangano; L Chambrone; R van Noort; C Miller; P Hatton; C Mangano
Journal:  Int J Biomater       Date:  2014-12-01

8.  Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study.

Authors:  Francesco Mangano; Fabrizia Luongo; Jamil Awad Shibli; Sukumaran Anil; Carlo Mangano
Journal:  Int J Dent       Date:  2014-12-14

9.  The Influence of Electrolytic Concentration on the Electrochemical Deposition of Calcium Phosphate Coating on a Direct Laser Metal Forming Surface.

Authors:  Qianyue Sun; Yuhui Yang; Wenjing Luo; Jinghui Zhao; Yanmin Zhou
Journal:  Int J Anal Chem       Date:  2017-01-29       Impact factor: 1.885

10.  Enhanced Osseointegration by the Hierarchical Micro-Nano Topography on Selective Laser Melting Ti-6Al-4V Dental Implants.

Authors:  Tianyu Shu; Yuchen Zhang; Guo Sun; Yang Pan; Gang He; Yilong Cheng; Ang Li; Dandan Pei
Journal:  Front Bioeng Biotechnol       Date:  2021-01-07
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.