Literature DB >> 2162271

Aortic compliance measured by non-invasive Doppler ultrasound: description of a method and its reproducibility.

J S Wright1, J K Cruickshank, S Kontis, C Doré, R G Gosling.   

Abstract

1. Aortic compliance (expressed as percentage increase in lumen diameter for a pulse pressure of 10 mmHg) was calculated from the characteristic pulse wave velocity deduced from 'foot to foot' transit times of the blood flow pulse over a measured length of aorta. Two continuous wave Doppler ultrasound transducers were used: one insonating the root of the left subclavian artery, the other the abdominal aorta proximal to its bifurcation. Measurements were made after the subject had been supine for 5 min to achieve stable conditions. 2. Transit times were calculated on-line in real-time from the delay between the start of the systolic upstroke in the flow velocity sonograms recorded by the two transducers. 3. Within-visit variation was minimized by measuring over 45 cardiac cycles repeated three separate times and calculating an overall mean value for aortic compliance. A full measurement took 5-10 min. 4. Reproducibility of this overall mean value of aortic compliance was assessed at 1 month in 30 subjects (aged 60 +/- 7 years, mean +/- SD) and at 3 months in 23 different subjects (59 +/- 8 years). Aortic compliance values ranged from 0.1 to 2.0%/10 mmHg. 5. The mean paired difference between aortic compliance values was -0.02 between 0 and 1 months, and 0.03 between 0 and 3 months, with respective 95% confidence limits of -0.06 to 0.03 and -0.03 to 0.09 embracing zero, thus not differing significantly from baseline.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2162271     DOI: 10.1042/cs0780463

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  11 in total

1.  Quantification of aortic elasticity: development and experimental validation of a method using computed tomography.

Authors:  Marika Ganten; Jan M Boese; David Leitermann; Wolfhard Semmler
Journal:  Eur Radiol       Date:  2005-07-26       Impact factor: 5.315

Review 2.  Developments in cardiovascular ultrasound. Part 2: Arterial applications.

Authors:  P R Hoskins; P J Fish; W N McDicken; C Moran
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

3.  Accuracy of arterial pulse-wave velocity measurement using MR.

Authors:  B D Bolster; E Atalar; C J Hardy; E R McVeigh
Journal:  J Magn Reson Imaging       Date:  1998 Jul-Aug       Impact factor: 4.813

4.  Feasibility of dual Doppler velocity measurements to estimate volume pulsations of an arterial segment.

Authors:  Craig J Hartley; Anilkumar K Reddy; Sridhar Madala; Mark L Entman; George E Taffet
Journal:  Ultrasound Med Biol       Date:  2010-07       Impact factor: 2.998

5.  Real-time measurement of pulse wave velocity from arterial pressure waveforms.

Authors:  M W Ramsey; W R Stewart; C J Jones
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

6.  Changes in carotid blood flow and electrocardiogram in humans during and after walking on a treadmill.

Authors:  J He; Z L Jiang; H Tanaka; T Ikehara; A Takahashi; H Yamaguchi; H Miyamoto; T Iritani; Y Kinouchi
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993

7.  Abnormal left ventricular mass and aortic distensibility in pediatric dialysis patients.

Authors:  Renee F Robinson; Milap C Nahata; Elizabeth Sparks; Curt Daniels; Donald L Batisky; John R Hayes; John D Mahan
Journal:  Pediatr Nephrol       Date:  2004-10-27       Impact factor: 3.714

Review 8.  Arterial Stiffness in CKD: A Review.

Authors:  Raymond R Townsend
Journal:  Am J Kidney Dis       Date:  2018-06-19       Impact factor: 8.860

9.  Arterial stiffness in the young: assessment, determinants, and implications.

Authors:  Yiu-Fai Cheung
Journal:  Korean Circ J       Date:  2010-04-22       Impact factor: 3.243

10.  Growth in utero, adult blood pressure, and arterial compliance.

Authors:  C N Martyn; D J Barker; S Jespersen; S Greenwald; C Osmond; C Berry
Journal:  Br Heart J       Date:  1995-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.