Literature DB >> 21618933

The influence of material and design on total knee replacement wear.

Aaron Essner1, Lizeth Herrera, Phillip Hughes, Mark Kester.   

Abstract

It is difficult for surgeons to make the decision on which design or material to use given the different options available. Marketing claims and direct-to-consumer advertising certainly complicate this further. One company may claim a higher percentage of wear reduction with their bearing surfaces compared with those of another manufacturer. If the percentage of wear reduction is lower, it is unclear as to whether this creates a more effective technology for reducing wear in the clinical situation. The relative contribution and relationship of design and materials to wear performance must be considered before making that important judgment. To examine the overall influence of implant design on wear reduction, a knee simulator study was undertaken. This simulator study compared the Oxinium Genesis II system with the Triathlon Conventional and Triathlon X3 knee systems under physiologic stair-climb loading and motion profiles. This allows a similar comparison of material effect within one design but also a global comparison across designs. Test results show the Triathlon Conventional and Triathlon X3 knee systems have superior wear resistance compared with that of the Genesis II Oxinium system under stair-climbing simulation. This finding indicates that implant design plays a more significant role in knee wear reduction than material. Although material technology may improve a given knee system's ability to wear, design geometry has a first-order effect and should be addressed before materials. This study represents an effort to differentiate design effect from two different approaches to material enhancement. The results of this study support the predominance of design in knee replacement wear performance. Ultimately, only clinical evidence such as published studies or outcomes reported in the available joint registries will establish whether any material or design can achieve a 30-year outcome.

Mesh:

Substances:

Year:  2011        PMID: 21618933     DOI: 10.1055/s-0031-1275390

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  8 in total

1.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

2.  Toward the interpretation of the combined effect of size and body weight on the tribological performance of total knee prostheses.

Authors:  Santina Battaglia; Paola Taddei; Silvia Tozzi; Alessandra Sudanese; Saverio Affatato
Journal:  Int Orthop       Date:  2014-02-26       Impact factor: 3.075

Review 3.  Toward engineering a biological joint replacement.

Authors:  Grace D O'Connell; Eric G Lima; Liming Bian; Nadeen O Chahine; Michael B Albro; James L Cook; Gerard A Ateshian; Clark T Hung
Journal:  J Knee Surg       Date:  2012-07       Impact factor: 2.757

4.  In vitro effects on mobile polyethylene insert under highly demanding daily activities: stair climbing.

Authors:  Sami Abdel Jaber; Paola Taddei; Silvia Tozzi; Alessandra Sudanese; Saverio Affatato
Journal:  Int Orthop       Date:  2014-12-14       Impact factor: 3.075

5.  Comparison of patient reported outcomes after Triathlon(®) and Kinemax Plus prostheses.

Authors:  S Dixon; A W Blom; M R Whitehouse; V Wylde
Journal:  Ann R Coll Surg Engl       Date:  2014-01       Impact factor: 1.891

6.  Ten-Year Results of the Triathlon Knee Replacement: A Cohort Study.

Authors:  Vikki Wylde; Chris Penfold; Alice Rose; Elizabeth Bradshaw; Michael R Whitehouse; Ashley W Blom
Journal:  Cureus       Date:  2021-05-24

7.  Metallosis Presenting as Knee Pain 26 years after Primary Total Knee Arthroplasty.

Authors:  Behnam Sharareh; Duy L Phan; Wamda Goreal; Ran Schwarzkopf
Journal:  J Orthop Case Rep       Date:  2015 Apr-Jun

8.  Computational wear prediction of insert conformity and material on mobile-bearing unicompartmental knee arthroplasty.

Authors:  Y-G Koh; J-A Lee; H-Y Lee; H-J Kim; K-T Kang
Journal:  Bone Joint Res       Date:  2019-12-03       Impact factor: 5.853

  8 in total