Literature DB >> 21617743

Preliminary Investigation of the Dosimetric Properties of 'RadGel'

J R Newton1, A Thomas, A Appleby, C Marsden, E A Christman, J G Wolodzko, M Oldham.   

Abstract

A preliminary investigation into the efficacy of a new 3D dosimetry material, RadGel™, for verification of radiation therapy dose distributions is presented. Small volumes of RadGel™ were found to exhibit a linear, reproducible response to dose. A gradual increase in optical-density (OD) with time was observed, suggesting scanning should be completed within 18 hours to keep a linear correlation of R(2) > 0.99. A larger 10 cm diameter volume of RadGel™ was irradiated with a rotationally symmetric "spoke" plan designed to rigorously evaluate scanner/dosimeter combined performance. The dosimeter was imaged with the Duke Mid-sized Optical-CT Scanner (DMOS). Promising OD and corresponding dose maps were obtained. Edge artefacts were observed and are suspected to be exacerbated by the particular container used in this early study. Further studies will evaluate new containers and methods for refractive matching at the gel-container-fluid interface.

Entities:  

Year:  2011        PMID: 21617743      PMCID: PMC3100579          DOI: 10.1088/1742-6596/250/1/012011

Source DB:  PubMed          Journal:  J Phys Conf Ser        ISSN: 1742-6588


  6 in total

1.  Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry.

Authors:  Nikola Krstajić; Simon J Doran
Journal:  Phys Med Biol       Date:  2006-04-03       Impact factor: 3.609

2.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.

Authors:  H S Sakhalkar; J Adamovics; G Ibbott; M Oldham
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

3.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner.

Authors:  J C Gore; M Ranade; M J Maryañski; R J Schulz
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

4.  CCD imaging for optical tomography of gel radiation dosimeters.

Authors:  J G Wolodzko; C Marsden; A Appleby
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

5.  Fast, large field-of-view, telecentric optical-CT scanning system for 3D radiochromic dosimetry.

Authors:  A Thomas; M Oldham
Journal:  J Phys Conf Ser       Date:  2010-01-01

6.  Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter.

Authors:  R G Kelly; K J Jordan; J J Battista
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

  6 in total
  1 in total

1.  Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.

Authors:  Asghar Mesbahi; Vahid Jafarzadeh; Nahideh Gharehaghaji
Journal:  Rep Pract Oncol Radiother       Date:  2012-04-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.