Literature DB >> 21615758

Transseptal left ventricular endocardial pacing reduces dispersion of ventricular repolarization.

Paul A Scott1, Arthur M Yue, Edd Watts, Mehmood Zeb, Paul R Roberts, John M Morgan.   

Abstract

BACKGROUND: Cardiac resynchronization therapy (CRT) may be proarrhythmic in some patients. This may be due to the effect of left ventricular (LV) epicardial pacing on ventricular repolarization. The purpose of this study was to evaluate the effect of endocardial versus epicardial LV biventricular pacing on surface electrocardiogram (ECG) parameters that are known markers of arrhythmogenic repolarization.
METHODS: ECG markers of repolarization (QT dispersion, QTD; T peak to end, T(peak-end) ; T(peak-end) dispersion, T(peak-end) D; QTc) were retrospectively measured before and after CRT in seven patients with transseptal LV endocardial leads (TS group), 28 matched patients with coronary sinus (CS) LV leads (CS group), and eight patients with surgical LV epicardial leads (SUR group). All ECGs were scanned and analyzed using digital callipers.
RESULTS: Compared to the CS group, the TS group CRT was associated with a significant postpacing reduction in QTD (-45.2 ± 35.6 vs -4.3 ± 43.6 ms, P = 0.03) and T(peak-end) (-24.2 ± 22.1 vs 3.4 ± 26.7 ms, P = 0.02). There was a nonsignificant post-CRT reduction in both T(peak-end) D (-11.3 ± 31.0 vs 2.4 ± 28.9 ms, P = 0.27) and QTc (-50.0 ± 46.4 vs 4.4 ± 70.2 ms, P = 0.06) in the TS versus the CS group. In contrast, there were no differences between the SUR and CS groups in terms of the effect of CRT on these repolarization parameters.
CONCLUSIONS: CRT with (atrial transseptal) endocardial LV lead placement is associated with repolarization characteristics that are considered to be less arrhythmogenic than those generated by CS (epicardial) LV lead placement. Further work is needed to determine whether these changes translate to a reduction in proarrhythmia. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21615758     DOI: 10.1111/j.1540-8159.2011.03138.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

Review 1.  Device therapies: new indications and future directions.

Authors:  Prabhat Kumar; Jennifer D Schwartz
Journal:  Curr Cardiol Rev       Date:  2015

2.  Endocardial biventricular pacing for chronic heart failure patients: Effect on transmural dispersion of repolarization.

Authors:  Muhammad Yamin; Yoga Yuniadi; Idrus Alwi; Siti Setiati; Muhammad Munawar
Journal:  J Arrhythm       Date:  2019-06-12

3.  Long-term single-centre large volume experience with transseptal endocardial left ventricular lead implantation.

Authors:  László Gellér; Zoltán Salló; Levente Molnár; Tamás Tahin; Emin Evren Özcan; Valentina Kutyifa; István Osztheimer; Szabolcs Szilágyi; Nándor Szegedi; Pál Ábrahám; Astrid Apor; Klaudia Vivien Nagy; Annamária Kosztin; Dávid Becker; Szilvia Herczeg; Endre Zima; Béla Merkely
Journal:  Europace       Date:  2019-08-01       Impact factor: 5.214

Review 4.  Understanding non-response to cardiac resynchronisation therapy: common problems and potential solutions.

Authors:  Benjamin J Sieniewicz; Justin Gould; Bradley Porter; Baldeep S Sidhu; Thomas Teall; Jessica Webb; Gerarld Carr-White; Christopher A Rinaldi
Journal:  Heart Fail Rev       Date:  2019-01       Impact factor: 4.214

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.