Literature DB >> 21610440

Complications and hardware removal after open reduction and internal fixation of humeral fractures.

Scott Lovald1, Deana Mercer, Jean Hanson, Ian Cowgill, Meghan Erdman, Paul Robinson, Beverly Diamond.   

Abstract

BACKGROUND: The purpose of this study was to review internal fixation of humerus fractures using a large national database and assess the incidence of implant removal procedures based on patient characteristics.
METHODS: The 2007 Nationwide Inpatient Sample was used to identify two different sets of patients: (1) all patients who received an open internal fixation procedure for a fracture of the upper end, shaft, or lower end of the humerus; and (2) all patients with a removal of implanted devices from the humerus. Patient variables included age, gender, race/ethnicity, median household income, patient geographic region, metropolitan location, and primary expected payor. The differences of characteristics between both groups were determined using χ, Fisher's exact, or unpaired t tests.
RESULTS: Open reduction with internal fixation was reported in 7,391 patients. Hardware removals were reported in 751 patients who were determined to have an associated diagnosed complication. From these numbers, the "failure" removal rate as a percentage of the total number of procedures for the year was 10.2%. Nonunion (17.5%) and Mechanical Complication of the Implant (16.2%) were the most common complications. Both payor (p=0.0023) and age (p<0.0001) were found to have significantly different distributions among the open reduction with internal fixation and removal groups.
CONCLUSION: These results suggest that the age of the patient and the patient's ability to pay may influence the likelihood of an implant removal procedure. The results will help identify patients who are at high risk for revision and who may benefit from preventative care.

Entities:  

Mesh:

Year:  2011        PMID: 21610440     DOI: 10.1097/TA.0b013e318215bedd

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  14 in total

1.  Use of high-speed burr and water-based lubricant in the partial removal of surgical plates: A technique Guide.

Authors:  Jon E Hammarstedt; Grigory E Gershkovich; Daniel P Mass
Journal:  J Clin Orthop Trauma       Date:  2018-05-24

2.  A Novel Surgical Technique for Removing Buried Cannulated Screws Using a Guidewire and Countersink: A Report of Two Cases.

Authors:  Yongsheng Chen; Krishna Prasad Giri; Christopher Jon Pearce
Journal:  Open Orthop J       Date:  2015-06-26

3.  Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate.

Authors:  Hyoung-Seok Jung; Yoo-Sun Won; Yang-Seon Choi; Jae-Sung Lee
Journal:  Eur J Trauma Emerg Surg       Date:  2022-08-01       Impact factor: 2.374

4.  Implant Removal Due to Infection After Open Reduction and Internal Fixation: Trends and Predictors.

Authors:  Alec S Kellish; Alisina Shahi; Julio A Rodriguez; Kudret Usmani; Michael Boniello; Ali Oliashirazi; Kenneth Graf; Henry Dolch; David Fuller; Rakesh P Mashru
Journal:  Arch Bone Jt Surg       Date:  2022-06

5.  Hardware Removal Due to Infection after Open Reduction and Internal Fixation: Trends and Predictors.

Authors:  Mohammad R Rasouli; Jessica Viola; Mitchell G Maltenfort; Alisina Shahi; Javad Parvizi; James C Krieg
Journal:  Arch Bone Jt Surg       Date:  2015-07

6.  Indications for implant removal after fracture healing: a review of the literature.

Authors:  D I Vos; M H J Verhofstad
Journal:  Eur J Trauma Emerg Surg       Date:  2013-04-12       Impact factor: 3.693

7.  Elective implant removal in symptomatic patients after internal fixation of proximal humerus fractures improves clinical outcome.

Authors:  Yves P Acklin; Christian Michelitsch; Christoph Sommer
Journal:  BMC Musculoskelet Disord       Date:  2016-03-10       Impact factor: 2.362

8.  An antibacterial and absorbable silk-based fixation material with impressive mechanical properties and biocompatibility.

Authors:  Chenglong Shi; Xiaobing Pu; Guan Zheng; Xinglong Feng; Xuan Yang; Baoliang Zhang; Yu Zhang; Qingshui Yin; Hong Xia
Journal:  Sci Rep       Date:  2016-11-21       Impact factor: 4.379

9.  A novel implant removal technique by endoscopy.

Authors:  Chang Heng Liu; Wen Lin Yeh; Ping Jui Tsai; Kuo Feng Fan; Hung Wei Cheng; Jian Ming Chen
Journal:  J Orthop Surg Res       Date:  2018-04-06       Impact factor: 2.359

10.  A novel technique for pediatric femoral locked submuscular plate removal: the 'push-pull' technique.

Authors:  Martin F Hoffmann; John Gburek; Clifford B Jones
Journal:  J Orthop Surg Res       Date:  2013-07-11       Impact factor: 2.359