Literature DB >> 21609700

Automation of three-dimensional cell culture in arrayed microfluidic devices.

Sara I Montanez-Sauri1, Kyung Eun Sung, John P Puccinelli, Carolyn Pehlke, David J Beebe.   

Abstract

The increasing interest in studying the interactions between cells and the extracellular matrix (ECM) has created a need for high throughput low-cost three-dimensional (3D) culture systems. The recent development of tubeless microfluidics via passive pumping provides a high throughput microchannel culture platform compatible with existing high throughput infrastructures (e.g., automated liquid handlers). Here, we build on a previously reported high throughput two-dimensional system to create a robust automated system for 3D culture. Operational controls including temperature and sample handling have been characterized and automated. Human mammary fibroblasts (HMFs) suspended in type I collagen are loaded and cultured in microchannel arrays and used to optimize the system operational parameters. A Peltier cooler maintains the collagen as a liquid at 4 °C during cell seeding, followed by polymerization at 37 °C. Optimization of this platform is discussed (e.g., controlling collagen contraction, increasing cell viability, preventing the removal of microchannel contents), and 3D distribution of HMFs is examined by fluorescent microscopy. Finally, we validate the platform by automating a previously developed 3D breast carcinoma coculture assay. The platform allows more efficient 3D culture experiments and lays the foundation for high throughput studies of cell-ECM interactions.
Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21609700      PMCID: PMC3104941          DOI: 10.1016/j.jala.2011.02.003

Source DB:  PubMed          Journal:  J Lab Autom        ISSN: 2211-0682


  35 in total

1.  Cell culture: biology's new dimension.

Authors:  Alison Abbott
Journal:  Nature       Date:  2003-08-21       Impact factor: 49.962

2.  Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells.

Authors:  Daniel G Anderson; Shulamit Levenberg; Robert Langer
Journal:  Nat Biotechnol       Date:  2004-06-13       Impact factor: 54.908

3.  Human mesenchymal stem cells tissue development in 3D PET matrices.

Authors:  Warren L Grayson; Teng Ma; Bruce Bunnell
Journal:  Biotechnol Prog       Date:  2004 May-Jun

4.  Reconstruction of functionally normal and malignant human breast tissues in mice.

Authors:  Charlotte Kuperwasser; Tony Chavarria; Min Wu; Greg Magrane; Joe W Gray; Loucinda Carey; Andrea Richardson; Robert A Weinberg
Journal:  Proc Natl Acad Sci U S A       Date:  2004-03-29       Impact factor: 11.205

Review 5.  Fibroblast mechanics in 3D collagen matrices.

Authors:  Sangmyung Rhee; Frederick Grinnell
Journal:  Adv Drug Deliv Rev       Date:  2007-08-14       Impact factor: 15.470

6.  Adapting Cell-Based Assays to the High Throughput Screening Platform: Problems Encountered and Lessons Learned.

Authors:  Clinton B Maddox; Lynn Rasmussen; E Lucile White
Journal:  JALA Charlottesv Va       Date:  2008-06

Review 7.  High-throughput screening of cell responses to biomaterials.

Authors:  Marjo Yliperttula; Bong Geun Chung; Akshay Navaladi; Amir Manbachi; Arto Urtti
Journal:  Eur J Pharm Sci       Date:  2008-05-21       Impact factor: 4.384

Review 8.  Screening the cellular microenvironment: a role for microfluidics.

Authors:  Jay W Warrick; William L Murphy; David J Beebe
Journal:  IEEE Rev Biomed Eng       Date:  2008-11-05

9.  Taking cell-matrix adhesions to the third dimension.

Authors:  E Cukierman; R Pankov; D R Stevens; K M Yamada
Journal:  Science       Date:  2001-11-23       Impact factor: 47.728

10.  Control of 3-dimensional collagen matrix polymerization for reproducible human mammary fibroblast cell culture in microfluidic devices.

Authors:  Kyung Eun Sung; Gui Su; Carolyn Pehlke; Steven M Trier; Kevin W Eliceiri; Patricia J Keely; Andreas Friedl; David J Beebe
Journal:  Biomaterials       Date:  2009-06-21       Impact factor: 12.479

View more
  18 in total

Review 1.  Microfluidic cell chips for high-throughput drug screening.

Authors:  Chun-Wei Chi; Ah Rezwanuddin Ahmed; Zeynep Dereli-Korkut; Sihong Wang
Journal:  Bioanalysis       Date:  2016-04-13       Impact factor: 2.681

2.  Single cell functional analysis of multiple myeloma cell populations correlates with diffusion profiles in static microfluidic coculture systems.

Authors:  Thomas A Moore; Edmond W K Young
Journal:  Biomicrofluidics       Date:  2016-07-15       Impact factor: 2.800

3.  Adaptation of a Simple Microfluidic Platform for High-Dimensional Quantitative Morphological Analysis of Human Mesenchymal Stromal Cells on Polystyrene-Based Substrates.

Authors:  Johnny Lam; Ross A Marklein; Jose A Jimenez-Torres; David J Beebe; Steven R Bauer; Kyung E Sung
Journal:  SLAS Technol       Date:  2017-08-21       Impact factor: 3.047

4.  Platform for high-throughput testing of the effect of soluble compounds on 3D cell cultures.

Authors:  Frédérique Deiss; Aaron Mazzeo; Estrella Hong; Donald E Ingber; Ratmir Derda; George M Whitesides
Journal:  Anal Chem       Date:  2013-08-16       Impact factor: 6.986

Review 5.  Microscale screening systems for 3D cellular microenvironments: platforms, advances, and challenges.

Authors:  Sara I Montanez-Sauri; David J Beebe; Kyung Eun Sung
Journal:  Cell Mol Life Sci       Date:  2014-10-02       Impact factor: 9.261

6.  Integrating 3D Cell Culture of PC12 Cells with Microchip-Based Electrochemical Detection.

Authors:  Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2019-01-29       Impact factor: 2.896

7.  Enabling screening in 3D microenvironments: probing matrix and stromal effects on the morphology and proliferation of T47D breast carcinoma cells.

Authors:  Sara I Montanez-Sauri; Kyung Eun Sung; Erwin Berthier; David J Beebe
Journal:  Integr Biol (Camb)       Date:  2013-03       Impact factor: 2.192

Review 8.  Building risk-on-a-chip models to improve breast cancer risk assessment and prevention.

Authors:  Pierre-Alexandre Vidi; James F Leary; Sophie A Lelièvre
Journal:  Integr Biol (Camb)       Date:  2013-09       Impact factor: 2.192

Review 9.  Microengineered tumor models: insights & opportunities from a physical sciences-oncology perspective.

Authors:  Peter DelNero; Young Hye Song; Claudia Fischbach
Journal:  Biomed Microdevices       Date:  2013-08       Impact factor: 2.838

Review 10.  Microfluidic 3D cell culture: potential application for tissue-based bioassays.

Authors:  Xiujun James Li; Alejandra V Valadez; Peng Zuo; Zhihong Nie
Journal:  Bioanalysis       Date:  2012-06       Impact factor: 2.681

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.