Entrance skin dose during radiofrequency catheter ablation for tachyarrhythmia: a multicenter study.

Takashi Kidouchi1, Shigeru Suzuki, Shigeru Furui, Haruo Mitani, Junichi Nitta, Kunihiro Matsumoto, Kuni Ohtomo.   

Abstract

BACKGROUND: To assess the entrance skin dose (ESD) during radiofrequency catheter ablation procedures for tachyarrhythmia including atrial fibrillation (Af).
METHODS: This study focused on 99 consecutive patients who underwent procedures for tachyarrhythmia (Af; n = 34, non-Af; n = 65) in three institutions. The non-Af group included atrial flutter, atrial tachycardia, paroxysmal supraventricular tachycardia, ventricular tachycardia, ventricular premature contraction, atrial premature contraction, atrioventricular nodal reentry tachycardia, and Wolff-Parkinson-White syndrome. In two of the three institutions, the procedures were performed for both Af and non-Af. The ESDs were measured using 100 radiosensitive indicators attached to the back of each patient's jacket at 5-cm intervals. For statistical analyses, multiple regression analysis (the dependent variable, Max-ESD; and the independent variables, dose area product [DAP], total fluoroscopic time [TFT], body mass index, etc.), Pearson's correlation test, and the Mann-Whitney test were employed.
RESULTS: The overall averages for the TFTs, the DAPs, and the Max-ESDs were 49.9 ± 28.2 minutes, 71.2 ± 73.7 Gy cm(2) , and 0.57 ± 0.51 Gy, respectively. DAP was positively related to the Max-ESD and was significant in stepwise multiple regression analysis (P < 0.0001). There was a significant association between TFT and Max-ESD in five of the six kinds of angiographic unit, and between DAP and Max-ESD in all three systems with available DAP measures. In one institution, TFT, DAP, and Max-ESD differed significantly between the Af and non-Af groups (P = 0.0002, P < 0.0001, and P < 0.0001).
CONCLUSIONS: During the cardiac catheter ablation, ESDs of only a few patients exceeded the thresholds of radiation skin injuries, and the DAP proved useful to estimate each patient's Max-ESD. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21609338     DOI: 10.1111/j.1540-8159.2010.03016.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Feasibility of zero or near zero fluoroscopy during catheter ablation procedures.

Authors:  Laurent M Haegeli; Linda Stutz; Mohammed Mohsen; Thomas Wolber; Corinna Brunckhorst; Chol-Jun On; Firat Duru
Journal:  Cardiol J       Date:  2018-04-03       Impact factor: 2.737

Review 2.  Catheter Ablation of Atrial Fibrillation Without Radiation Exposure Using A 3D Mapping System.

Authors:  Marco Scaglione; Elisa Ebrille; Francesca Di Clemente; Fiorenzo Gaita; Jason S Bradfield
Journal:  J Atr Fibrillation       Date:  2015-02-28

3.  Observations and Considerations on Patient X-ray Exposure in the Electrophysiology Lab.

Authors:  Xianxian Jiang; Lukas Rc Dekker
Journal:  Arrhythm Electrophysiol Rev       Date:  2013-11-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.