Literature DB >> 21607708

A low-cost reader for automatically collecting vital signs in hospitals.

Kuo-Yi Chen1, Fuh-Gwo Chen, Ting-Wei Hou.   

Abstract

Nowadays, the use of medical sensors with embedded communication modules provides accurate number reading and automatic recording. However, such readers are usually more expensive than similar devices without an embedded communication module. Further, different vendors define proprietary communication protocols and data formats for their own medical sensors. Due to the twin issues of high cost and diversity of standards, the automatic collection of patients' vital signs is not common in hospitals, meaning that medical staff need to periodically collect all patients' vital signs. This may cause further problems in caring for patients. We propose a low-cost reader using a cheap web camera to automatically read vital sign monitors in hospitals. The reader uses a high-resolution web camera to take a series of pictures of vital sign monitors and recognizes vital signs in electronic form and then forwards that information to hospital information systems. Its major benefit is that different sensors equipped with vital sign monitors, whether they include a computer communications module, can be digital-number recognized. It saves time in recording monitored vital signs of patients widely located in hospitals. In sum medical staff care of patients may be usefully assisted by the proposed reader which automatically collects all patients' vital signs, significantly improving patient care.

Entities:  

Mesh:

Year:  2011        PMID: 21607708     DOI: 10.1007/s10916-011-9732-z

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  9 in total

1.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

Review 2.  Medical device regulation: an introduction for the practicing physician.

Authors:  William H Maisel
Journal:  Ann Intern Med       Date:  2004-02-17       Impact factor: 25.391

3.  Intraoperative determination of intestinal viability: a comparison with transserosal pulse oximetry and histopathological examination.

Authors:  Mehmet Erikoglu; Adnan Kaynak; Ertan Abbas Beyatli; Hatice Toy
Journal:  J Surg Res       Date:  2005-04-25       Impact factor: 2.192

4.  A wireless PDA-based physiological monitoring system for patient transport.

Authors:  Yuan-Hsiang Lin; I-Chien Jan; Patrick Chow-In Ko; Yen-Yu Chen; Jau-Min Wong; Gwo-Jen Jan
Journal:  IEEE Trans Inf Technol Biomed       Date:  2004-12

5.  Wireless body sensor network using medical implant band.

Authors:  Mehmet R Yuce; Steven W P Ng; Naung L Myo; Jamil Y Khan; Wentai Liu
Journal:  J Med Syst       Date:  2007-12       Impact factor: 4.460

6.  Physiological signal based entity authentication for body area sensor networks and mobile healthcare systems.

Authors:  Shu-Di Bao; Yuan-Ting Zhang; Lian-Feng Shen
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

7.  The computer based patient record: a strategic issue in process innovation.

Authors:  C Sicotte; J L Denis; P Lehoux
Journal:  J Med Syst       Date:  1998-12       Impact factor: 4.460

8.  Adult vallecular cyst: thirteen-year experience.

Authors:  Gilead Berger; Eran Averbuch; Keren Zilka; Rachel Berger; Dov Ophir
Journal:  Otolaryngol Head Neck Surg       Date:  2008-03       Impact factor: 3.497

9.  Public health data collection and sharing using HIPAA messages.

Authors:  Min Wu; Tian Zhao; Changshan Wu
Journal:  J Med Syst       Date:  2005-08       Impact factor: 4.460

  9 in total
  1 in total

1.  Design and Construction of a Microcontroller-Based Ventilator Synchronized with Pulse Oximeter.

Authors:  Adem Gölcük; Hakan Işık; İnan Güler
Journal:  J Med Syst       Date:  2016-06-11       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.