Literature DB >> 15615034

A wireless PDA-based physiological monitoring system for patient transport.

Yuan-Hsiang Lin1, I-Chien Jan, Patrick Chow-In Ko, Yen-Yu Chen, Jau-Min Wong, Gwo-Jen Jan.   

Abstract

This paper proposes a mobile patient monitoring system, which integrates current personal digital assistant (PDA) technology and wireless local area network (WLAN) technology. At the patient's location, a wireless PDA-based monitor is used to acquire continuously the patient's vital signs, including heart rate, three-lead electrocardiography, and SpO2. Through the WLAN, the patient's biosignals can be transmitted in real-time to a remote central management unit, and authorized medical staffs can access the data and the case history of the patient, either by the central management unit or the wireless devices. A prototype of this system has been developed and implemented. The system has been evaluated by technical verification, clinical test, and user survey. The evaluation of performance yields a high degree of satisfaction (mean = 4.64, standard deviation--SD = 0.53 in a five-point Likert scale) of users who used the PDA-based system for intrahospital transport. The results also show that the wireless PDA model is superior to the currently used monitors both in mobility and in usability, and is, therefore, better suited to patient transport.

Entities:  

Mesh:

Year:  2004        PMID: 15615034     DOI: 10.1109/titb.2004.837829

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  15 in total

1.  A low-cost reader for automatically collecting vital signs in hospitals.

Authors:  Kuo-Yi Chen; Fuh-Gwo Chen; Ting-Wei Hou
Journal:  J Med Syst       Date:  2011-05-24       Impact factor: 4.460

2.  Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System.

Authors:  Bor-Shyh Lin; Willy Chou; Hsing-Yu Wang; Yan-Jun Huang; Jeng-Shyang Pan
Journal:  IEEE J Transl Eng Health Med       Date:  2013-06-04       Impact factor: 3.316

3.  Real-Time Remote Health Monitoring Systems Using Body Sensor Information and Finger Vein Biometric Verification: A Multi-Layer Systematic Review.

Authors:  A H Mohsin; A A Zaidan; B B Zaidan; A S Albahri; O S Albahri; M A Alsalem; K I Mohammed
Journal:  J Med Syst       Date:  2018-10-16       Impact factor: 4.460

4.  Designing an emergency medical information system for the early stages of disasters in developing countries: the human interface advantage, simplicity and efficiency.

Authors:  Agung Budi Sutiono; Andri Qiantori; Samudra Prasetio; Hariyo Santoso; Hirohiko Suwa; Toshizumi Ohta; Taufik Hasan; Tri Wahyu Murni
Journal:  J Med Syst       Date:  2009-04-16       Impact factor: 4.460

5.  An implementation of wireless medical image transmission system on mobile devices.

Authors:  SangBock Lee; Taesoo Lee; Gyehwan Jin; Juhyun Hong
Journal:  J Med Syst       Date:  2008-12       Impact factor: 4.460

6.  A handheld computer as part of a portable in vivo knee joint load monitoring system.

Authors:  Ja Szivek; Vs Nandakumar; Cp Geffre; Cp Townsend
Journal:  J Med Device       Date:  2008-09-01       Impact factor: 0.582

Review 7.  A systematic review of the designs of clinical technology: findings and recommendations for future research.

Authors:  Greg Alexander; Nancy Staggers
Journal:  ANS Adv Nurs Sci       Date:  2009 Jul-Sep       Impact factor: 1.824

8.  SMART--an integrated wireless system for monitoring unattended patients.

Authors:  Dorothy W Curtis; Esteban J Pino; Jacob M Bailey; Eugene I Shih; Jason Waterman; Staal A Vinterbo; Thomas O Stair; John V Guttag; Robert A Greenes; Lucila Ohno-Machado
Journal:  J Am Med Inform Assoc       Date:  2007-10-18       Impact factor: 4.497

9.  Implementation of compressed sensing in telecardiology sensor networks.

Authors:  Eduardo Correia Pinheiro; Octavian Adrian Postolache; Pedro Silva Girão
Journal:  Int J Telemed Appl       Date:  2010-09-21

10.  A telemedicine instrument for remote evaluation of tremor: design and initial applications in fatigue and patients with Parkinson's disease.

Authors:  Mário C Barroso Júnior; Guilherme P Esteves; Thiago P Nunes; Lucia M G Silva; Alvaro C D Faria; Pedro L Melo
Journal:  Biomed Eng Online       Date:  2011-02-09       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.