Literature DB >> 21607640

Frameless stereotactic endoscope-assisted transoccipital hippocampal depth electrode placement: cadaveric demonstration of a new approach.

Biji Bahuleyan1, Melvin Omodon, Shenandoah Robinson, Alan R Cohen.   

Abstract

PURPOSE: Hippocampal recording using depth electrodes is indicated in a small subgroup of patients with medically intractable seizures. There are several conventional techniques for implantation of hippocampal depth electrodes. We describe a new method for hippocampal depth electrode placement using an image-guided endoscopic transoccipital route. This technique is simple and effective, eliminating several drawbacks of conventional techniques.
METHODS: One silicone-injected cadaver head was used. A rigid endoscope sheath was inserted through a transoccipital corridor into the atrium of the lateral ventricle and then advanced to the temporal horn. Each of the hemispheres was cannulated. The hippocampus was identified visually, and a depth electrode was inserted into the substance of the hippocampus along its long axis under direct vision.
RESULTS: In both hemispheres we were able to successfully implant the depth electrode within the hippocampus. The advantages of our technique over conventional approaches are (1) there is no need for frame-based stereotaxy, thus reducing operating time and patient discomfort, (2) the electrodes are inserted into the hippocampus under direct endoscopic visualization, reducing the chance of injury to vascular structures, (3) there is no need to insert a larger cannula into the hippocampus before placement of the electrodes, reducing trauma to the hippocampus, and (4) the number of electrodes within the hippocampus can be assessed at the end of the procedure, reducing malposition.
CONCLUSION: We believe that image-guided endoscopic transoccipital hippocampal depth electrode placement can be performed with precision equal or superior to conventional techniques but without their major disadvantages.

Entities:  

Mesh:

Year:  2011        PMID: 21607640     DOI: 10.1007/s00381-011-1489-7

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  10 in total

1.  Stereotactic electroencephalography with temporal grid and mesial temporal depth electrode coverage: does technique of depth electrode placement affect outcome?

Authors:  Jamie J Van Gompel; Fredric B Meyer; W Richard Marsh; Kendall H Lee; Gregory A Worrell
Journal:  J Neurosurg       Date:  2010-07       Impact factor: 5.115

2.  Depth electrode implantation in the length axis of the hippocampus for the presurgical evaluation of medial temporal lobe epilepsy: a computed tomography-based stereotactic insertion technique and its accuracy.

Authors:  D Van Roost; L Solymosi; J Schramm; B van Oosterwyck; C E Elger
Journal:  Neurosurgery       Date:  1998-10       Impact factor: 4.654

3.  An intra-arterial electrode for intracranial electro-encephalogram recordings.

Authors:  H Nakase; H Ohnishi; H Touho; J Karasawa; S Yamamoto; K Shimizu
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

4.  MRI confirmation of accuracy of freehand placement of mesial temporal lobe depth electrodes in the investigation of intractable epilepsy.

Authors:  K G Davies; B L Phillips; B P Hermann
Journal:  Br J Neurosurg       Date:  1996-04       Impact factor: 1.596

5.  Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: surgical technique.

Authors:  D R Blatt; S N Roper; W A Friedman
Journal:  Surg Neurol       Date:  1997-07

6.  A new multipurpose human brain depth probe.

Authors:  C D Ray
Journal:  J Neurosurg       Date:  1966-05       Impact factor: 5.115

7.  Intraventricular monitoring for temporal lobe epilepsy: report on technique and initial results in eight patients.

Authors:  J K Song; B Abou-Khalil; P E Konrad
Journal:  J Neurol Neurosurg Psychiatry       Date:  2003-05       Impact factor: 10.154

8.  Lateralization of temporal lobe foci: depth versus subdural electrodes.

Authors:  S Eisenschenk; R L Gilmore; J E Cibula; S N Roper
Journal:  Clin Neurophysiol       Date:  2001-05       Impact factor: 3.708

9.  Combined depth and subdural electrode investigation in uncontrolled epilepsy.

Authors:  S S Spencer; D D Spencer; P D Williamson; R Mattson
Journal:  Neurology       Date:  1990-01       Impact factor: 9.910

Review 10.  Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery.

Authors:  D A Ross; J A Brunberg; I Drury; T R Henry
Journal:  Neurosurgery       Date:  1996-08       Impact factor: 4.654

  10 in total
  1 in total

1.  Extraventricular long-axis cannulation of the hippocampus: technical considerations.

Authors:  Chengyuan Wu; Michael J LaRiviere; Nealen Laxpati; James J Evans; Robert E Gross; Ashwini D Sharan
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.