| Literature DB >> 21605401 |
Bernard Nkrumah1, Samuel Ek Acquah, Lukeman Ibrahim, Juergen May, Norbert Brattig, Egbert Tannich, Samuel Blay Nguah, Yaw Adu-Sarkodie, Frank Huenger.
Abstract
BACKGROUND: About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21605401 PMCID: PMC3118144 DOI: 10.1186/1471-2334-11-143
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Result interpretation by the Binax Now® RDT
| Positive Test | Negative Test | Invalid Test | |||
|---|---|---|---|---|---|
| C plus T1 | Positive for | C only | Negative | No Line | Invalid test. |
| Repeat test with a new kit. | |||||
| C plus T2 | Positive for | T1 or T2 only | Invalid test. Repeat | ||
| test with a new kit. | |||||
| C plus T1 | Positive for | T1 and T2 only | Invalid test. Repeat | ||
| and T2 | test with a new kit. | ||||
| another malaria species is not possible with this test. | |||||
Source: Binax NOW® reagent package insert, 2007 page 6.
Results of Giemsa stain, Partec Rapid Test® and Binax Now® RDT
| Positive | Negative | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| GM | 105* | 1 | 1 | - | - | 107 | 156§ | - | 156 |
| PT¥ | 105 | 1 | 1 | - | 4 | 111 | 152 | 0 | 152 |
| BN RDT¥ | 52* | - | - | 52 | 10 | 114 | 146 | 3 | 149 |
*2 slides with Trophozoites and Gametocytes
§2 slides with Gametocytes only
¥No Species differenciation
Performance characteristics of two different methods compared to Giemsa stain microscopy
| Test methods | ||
|---|---|---|
| Sensitivity | 100 | 97.2 |
| (95% CI) | (96.6-100) | (92.0-99.4) |
| Specificity | 97.4 | 93.6 |
| (95% CI) | (93.6-99.3) | (88.5-96.9) |
| PPV1 | 96.4 | 91.2 |
| (95% CI) | (91.0-99.0) | (84.5-95.7) |
| NPV2 | 100 | 98 |
| (95% CI) | (97.6-100) | (94.2-99.6) |
| PLR3 | 39 | 15.2 |
| (95% CI) | (14.8-103.0) | (8.3-27.6) |
| NLR4 | 0 | 0 |
| (95% CI) | (0.0-0.0) | (0.0-0.9) |
| kappa | 0.97 | 0.9 |
| Std Error | 0.06 | 0.06 |
| p value | < 0.001 | < 0.001 |
1 PPV: Positive predictive value 2 NPV: Negative predictive value
3 PLR: Positive likelihood ratio 4 NLR: Negative likelihood ratio
Comparison between BN RDT and PT using the ASSURED criteria
| BN RDT | PT§ | |
|---|---|---|
| Affordability | $1* | $ 0.5* |
| Sensitivity (%) | 96.5 | 95.6 |
| Specificity (%) | 98 | 96.7 |
| User-friendly | 6 steps | 3 steps |
| Rapid and robust | Yes | Yes |
| Equipment-free | Yes | No |
| Deliverable to end-users | Yes | Yes |
| Minimal Training | Yes | Yes |
* Data obtained from the manufacturer
§ $ 1300 price for Partec® fluorescence microscope (CyScope®)