Right ventricular function and left ventricular assist device placement: clinical considerations and outcomes.

Romeo Lainez1, Gene Parrino, Michael Bates.   

Abstract

The HeartMate II is an axial-flow left ventricular assist device that is approved for the treatment of advanced heart failure as a bridge to transplant or destination therapy. Despite the success of this device, right ventricular failure remains a persistent problem in most studies. Right ventricular dysfunction is usually defined as the need for right heart mechanical support or the persistent requirement for inotropes to support right heart function beyond 14 days. Over 21 months, 45 patients with end-stage heart disease underwent placement of the HeartMate II at our institution. This continuous cohort of patients underwent a retrospective review to evaluate the incidence of right heart failure. The perioperative survival was 91% with no incidents of mechanical support for the right ventricle and no requirements for inotropes beyond 14 days. This survival was consistent to beyond 1 year at the time of the study, and 18% of patients underwent heart transplant with 100% survival.

Entities:  

Keywords:  Heart failure; heart transplant; left ventricular assist device; right ventricular failure

Year:  2010        PMID: 21603391      PMCID: PMC3096228     

Source DB:  PubMed          Journal:  Ochsner J        ISSN: 1524-5012


  13 in total

1.  Right heart failure: best treated by avoidance.

Authors:  C H Van Meter
Journal:  Ann Thorac Surg       Date:  2001-03       Impact factor: 4.330

2.  Long-term use of a left ventricular assist device for end-stage heart failure.

Authors:  E A Rose; A C Gelijns; A J Moskowitz; D F Heitjan; L W Stevenson; W Dembitsky; J W Long; D D Ascheim; A R Tierney; R G Levitan; J T Watson; P Meier; N S Ronan; P A Shapiro; R M Lazar; L W Miller; L Gupta; O H Frazier; P Desvigne-Nickens; M C Oz; V L Poirier
Journal:  N Engl J Med       Date:  2001-11-15       Impact factor: 91.245

3.  Risk factors predictive of right ventricular failure after left ventricular assist device implantation.

Authors:  Stavros G Drakos; Lindsay Janicki; Benjamin D Horne; Abdallah G Kfoury; Bruce B Reid; Stephen Clayson; Kenneth Horton; Francois Haddad; Dean Y Li; Dale G Renlund; Patrick W Fisher
Journal:  Am J Cardiol       Date:  2010-02-13       Impact factor: 2.778

4.  Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation.

Authors:  O H Frazier; E A Rose; M C Oz; W Dembitsky; P McCarthy; B Radovancevic; V L Poirier; K A Dasse
Journal:  J Thorac Cardiovasc Surg       Date:  2001-12       Impact factor: 5.209

5.  Clinical management of continuous-flow left ventricular assist devices in advanced heart failure.

Authors:  Mark S Slaughter; Francis D Pagani; Joseph G Rogers; Leslie W Miller; Benjamin Sun; Stuart D Russell; Randall C Starling; Leway Chen; Andrew J Boyle; Suzanne Chillcott; Robert M Adamson; Margaret S Blood; Margarita T Camacho; Katherine A Idrissi; Michael Petty; Michael Sobieski; Susan Wright; Timothy J Myers; David J Farrar
Journal:  J Heart Lung Transplant       Date:  2010-02-24       Impact factor: 10.247

6.  Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.

Authors:  Robert L Kormos; Jeffrey J Teuteberg; Francis D Pagani; Stuart D Russell; Ranjit John; Leslie W Miller; Todd Massey; Carmelo A Milano; Nader Moazami; Kartik S Sundareswaran; David J Farrar
Journal:  J Thorac Cardiovasc Surg       Date:  2010-02-04       Impact factor: 5.209

7.  Risk score derived from pre-operative data analysis predicts the need for biventricular mechanical circulatory support.

Authors:  J Raymond Fitzpatrick; John R Frederick; Vivian M Hsu; Elliott D Kozin; Mary Lou O'Hara; Elan Howell; Deborah Dougherty; Ryan C McCormick; Carine A Laporte; Jeffrey E Cohen; Kevin W Southerland; Jessica L Howard; Mariell L Jessup; Rohinton J Morris; Michael A Acker; Y Joseph Woo
Journal:  J Heart Lung Transplant       Date:  2008-12       Impact factor: 10.247

8.  Advanced heart failure treated with continuous-flow left ventricular assist device.

Authors:  Mark S Slaughter; Joseph G Rogers; Carmelo A Milano; Stuart D Russell; John V Conte; David Feldman; Benjamin Sun; Antone J Tatooles; Reynolds M Delgado; James W Long; Thomas C Wozniak; Waqas Ghumman; David J Farrar; O Howard Frazier
Journal:  N Engl J Med       Date:  2009-11-17       Impact factor: 91.245

9.  Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device.

Authors:  J Raymond Fitzpatrick; John R Frederick; William Hiesinger; Vivian M Hsu; Ryan C McCormick; Elliott D Kozin; Carine M Laporte; Mary Lou O'Hara; Elan Howell; Deborah Dougherty; Jeffrey E Cohen; Kevin W Southerland; Jessica L Howard; E Carter Paulson; Michael A Acker; Rohinton J Morris; Y Joseph Woo
Journal:  J Thorac Cardiovasc Surg       Date:  2009-04       Impact factor: 5.209

10.  Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients.

Authors:  Yoshie Ochiai; Patrick M McCarthy; Nicholas G Smedira; Michael K Banbury; Jose L Navia; Jingyuan Feng; Amy P Hsu; Michael L Yeager; Tiffany Buda; Katherine J Hoercher; Michael W Howard; Masami Takagaki; Kazuyoshi Doi; Kiyotaka Fukamachi
Journal:  Circulation       Date:  2002-09-24       Impact factor: 29.690

View more