Literature DB >> 21602523

Impact of prosthesis--patient mismatch after mitral valve replacement: a multicentre analysis of early outcomes and mid-term survival.

William Y Shi1, Cheng-Hon Yap, Philip A Hayward, Diem T Dinh, Christopher M Reid, Gilbert C Shardey, Julian A Smith.   

Abstract

BACKGROUND: Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA). It is uncertain whether PPM after mitral valve replacement impacts upon clinical outcome. This was examined in an Australian population.
METHODS: From 2001 to 2009, 1006 mechanical and bioprosthetic mitral valves were implanted across 10 institutions. Effective orifice areas (EOA) were obtained from a literature review of in vivo echocardiographic data. Absent, moderate and severe PPM was defined as an indexed EOA (EOA/BSA) of >1.20 cm(2)/m(2), >0.90 to ≤1.20 cm(2)/m(2) and ≤0.9 cm(2)/m(2), respectively. Early outcomes and 7-year survival were compared between these three groups.
RESULTS: PPM was absent in 34%, moderate in 53% and severe in 13% of patients. Patients with PPM were more likely to be male (42% vs 52% vs 62%, p<0.0001) and obese (14% vs 20% vs 56%, p<0.0001). Postoperatively there was similar 30-day mortality (5% vs 5% vs 6%, p=0.83) and early any mortality/morbidity (24% vs 27% vs 29%, p=0.40). Seven-year survival was similar between groups (72±4.1% vs 76±3.2% vs 69±10.3%, p=0.76). PPM did not predict adverse events after logistic and Cox regressions with and without propensity score adjustment. Subgroup analyses of those with isolated mitral valve surgery, patients with preoperative congestive heart failure and non-obese patients failed to show an association between PPM and mid-term mortality.
CONCLUSIONS: Overall, PPM was not associated with poorer early outcomes or mid-term survival. Oversizing valves may be technically hazardous and do not yield superior outcomes. Easier implantation by appropriate sizing appears justified.

Entities:  

Mesh:

Year:  2011        PMID: 21602523     DOI: 10.1136/hrt.2010.219576

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  10 in total

1.  Weight gain potential-a neglected entity during valve replacement.

Authors:  Vijayanand Palanisamy; Karthik Raman; Anjith Prakash Rajakumar; Anbarasu Mohanraj; Jacob Jamesraj; Ejaz Ahmed Sheriff; Valikapthalil Mathew Kurian; Rajan Sethuratnam
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-07-19

2.  Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch after Mitral Valve Replacement: A Chinese Multicenter Clinical Study.

Authors:  Hua Cao; Zhihuang Qiu; Liangwan Chen; Daozhong Chen; Qiang Chen
Journal:  Med Sci Monit       Date:  2015-08-27

3.  Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients.

Authors:  Michel Pompeu Barros Oliveira Sá; Luiz Rafael Pereira Cavalcanti; Sérgio da Costa Rayol; Roberto Gouvea Silva Diniz; Alexandre Motta Menezes; Marie-Annick Clavel; Philippe Pibarot; Ricardo Carvalho Lima
Journal:  Braz J Cardiovasc Surg       Date:  2019 Mar-Apr

4.  Mitral valve replacement in mitral stenosis; the problem of small left ventricle.

Authors:  Hesham Alkady; Ahmed Saber; Sobhy Abouramadan; Ahmed Elnaggar; Sherif Nasr; Eman Mahmoud
Journal:  J Cardiothorac Surg       Date:  2020-04-22       Impact factor: 1.637

5.  The effect of patient-prosthesis mismatch on survival after aortic and mitral valve replacement: a 10 year, single institution experience.

Authors:  Sudeep Das De; Ashok Nanjappa; Karim Morcos; Sadia Aftab; John Butler; Vivek Pathi; Philip Curry; Sukumaran Nair
Journal:  J Cardiothorac Surg       Date:  2019-12-06       Impact factor: 1.637

6.  Prosthesis-Patient Mismatch after Mitral Valve Replacement: Comparison of Different Methods of Effective Orifice Area Calculation.

Authors:  In Jeong Cho; Geu Ru Hong; Seung Hyun Lee; Sak Lee; Byung Chul Chang; Chi Young Shim; Hyuk Jae Chang; Jong Won Ha; Namsik Chung
Journal:  Yonsei Med J       Date:  2016-03       Impact factor: 2.759

7.  Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

Authors:  Seung Hyun Lee; Byung Chul Chang; Young-Nam Youn; Hyun Chel Joo; Kyung-Jong Yoo; Sak Lee
Journal:  J Cardiothorac Surg       Date:  2017-10-10       Impact factor: 1.637

8.  Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China.

Authors:  Armah M Akuffu; Haige Zhao; Junnan Zheng; Yiming Ni
Journal:  J Cardiothorac Surg       Date:  2018-10-03       Impact factor: 1.637

9.  Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis.

Authors:  Meng-Wei Tan; Yi-Fan Bai; Xiao-Hong Liu; Zhi-Yun Xu; Zhao An; Ye Ma; Li-Bo Zhao; Bai-Ling Li
Journal:  J Geriatr Cardiol       Date:  2020-08       Impact factor: 3.327

Review 10.  Prosthesis-patient mismatch after mitral valve replacement: A pooled meta-analysis of Kaplan-Meier-derived individual patient data.

Authors:  Anton Tomšič; Bardia Arabkhani; Jan W Schoones; Jonathan R G Etnel; Nina A Marsan; Robert J M Klautz; Meindert Palmen
Journal:  J Card Surg       Date:  2020-10-21       Impact factor: 1.778

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.