A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.

Juliana Leme1, Jeison Fonseca, Eduardo Bock, Cibele da Silva, Bruno Utiyama da Silva, Alex Eugênio Dos Santos, Jarbas Dinkhuysen, Aron Andrade, José F Biscegli.   

Abstract

A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis.
© 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21595709     DOI: 10.1111/j.1525-1594.2011.01254.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  The Influence of Impeller Geometries on Hemolysis in Bearingless Centrifugal Pumps.

Authors:  Pascal Puentener; Marcel Schuck; Johann W Kolar
Journal:  IEEE Open J Eng Med Biol       Date:  2020-11-16

2.  Comparison and experimental validation of fluid dynamic numerical models for a clinical ventricular assist device.

Authors:  Jiafeng Zhang; Pei Zhang; Katharine H Fraser; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2013-02-27       Impact factor: 3.094

3.  Clinical evaluation of the Spiral Pump® after improvements to the original project in patients submitted to cardiac surgeries with cardiopulmonary bypass.

Authors:  Jarbas Jakson Dinkhuysen; Aron Jose Pazin de Andrade; Juliana Leme; Cibele Silva; Claudia Sanches Medina; Cristiane Célia Pereira; José Francisco Biscegli
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Jul-Sep
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.