Literature DB >> 21595098

Inferior vena cava variation compared to pulse contour analysis as predictors of fluid responsiveness: a prospective cohort study.

Enrique Machare-Delgado1, Matthew Decaro, Paul E Marik.   

Abstract

BACKGROUND: Both occult hypoperfusion and volume overload are associated with increased morbidity and mortality in critically ill patients. Accurately predicting fluid responsiveness (FRes) allows for optimization of cardiac performance while avoiding fluid overload and prolonged mechanical ventilation.
OBJECTIVE: To simultaneously assess the ability to predict FRes using the stroke volume variation (SVV) obtained with the Vigileo/Flotrac monitor and inferior vena cava respiratory variation (ΔIVC) measured by standard echocardiography ([ECHO) during mechanical ventilation.
METHODS: We included medical intensive care unit (ICU) patients undergoing mechanical ventilation that required vasopressors, had worsening organ function, and that were well adapted to the ventilator. We excluded patients requiring escalating doses of vasopressors, hemodialysis, with ascites and patients with atrial fibrillation or a heart rate >120/min. Stroke volume index (SVI) and SVV were obtained from the Vigileo monitor whereas ΔIVC was obtained with ECHO (M-mode). Doppler ECHO was used to measure SVI and used to determine FRes (defined by SVI increase ≥ 10%). A data set was obtained before and 30 minutes after a 10-minute fluid challenge (FC) with 500 mL of saline.
RESULTS: In all, 25 patients were prospectively enrolled over an 8-month period. A total of 12 patients had acute respiratory distress syndrome (ARDS), 3 had a cardiac arrest, and 10 had sepsis. The patients' mean age was 61.36 years (±13.7), study enrollment since ICU admission was 3.4 days (±3.39), the Sequential Organ Failure Assessment (SOFA) score was 12.44 (±2.59), and the tidal volume 8.6 mL/kg (±1.68). Of the 25 patients, 8 (32%) were FRes. The correlation coefficient between the baseline ΔIVC and percentage increase in SVI (by ECHO) after an FC was R(2) = .51 with a receiver operating characteristic (ROC) curve of 0.81 while that for the baseline SVV by Vigileo was R(2) = .12 with an ROC curve of 0.57. The mean SVI bias between ECHO and Vigileo was -2 mL/m(2), the precision was -18 to 14 and the mean error was 46%.
CONCLUSIONS: ECHO assessment of the IVC variation during mechanical ventilation may prove to be a useful technique to predict FRes and guide fluid resuscitation in the ICU. The SVV obtained with the Vigileo monitor failed to predict FRes likely due to lack of calibration and the use of a complex algorithm that may be unreliable in patients with sepsis.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21595098     DOI: 10.1177/0885066610384192

Source DB:  PubMed          Journal:  J Intensive Care Med        ISSN: 0885-0666            Impact factor:   3.510


  22 in total

1.  Fluid responsiveness raises many questions-echocardiography may be the answer.

Authors:  Chiara Lazzeri; Adriano Peris
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

2.  Usefulness of ultrasound imaging in overhydrated nephropathic patients.

Authors:  F Simoni; N Vitturi; M Dugo
Journal:  J Ultrasound       Date:  2016-06-11

Review 3.  Sepsis outside intensive care unit: the other side of the coin.

Authors:  F Mearelli; D Orso; N Fiotti; N Altamura; A Breglia; M De Nardo; I Paoli; M Zanetti; C Casarsa; G Biolo
Journal:  Infection       Date:  2014-08-11       Impact factor: 3.553

Review 4.  Applied physiology at the bedside to drive resuscitation algorithms.

Authors:  Andre L Holder; Michael R Pinsky
Journal:  J Cardiothorac Vasc Anesth       Date:  2014-12       Impact factor: 2.628

Review 5.  Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades.

Authors:  Antonio Messina; Lorenzo Calabrò; Luca Pugliese; Aulona Lulja; Alexandra Sopuch; Daniela Rosalba; Emanuela Morenghi; Glenn Hernandez; Xavier Monnet; Maurizio Cecconi
Journal:  Crit Care       Date:  2022-06-21       Impact factor: 19.334

Review 6.  Prediction of fluid responsiveness in ventilated patients.

Authors:  Mathieu Jozwiak; Xavier Monnet; Jean-Louis Teboul
Journal:  Ann Transl Med       Date:  2018-09

Review 7.  Physiological changes after fluid bolus therapy in sepsis: a systematic review of contemporary data.

Authors:  Neil J Glassford; Glenn M Eastwood; Rinaldo Bellomo
Journal:  Crit Care       Date:  2014-12-27       Impact factor: 9.097

8.  The caval index: an adequate non-invasive ultrasound parameter to predict fluid responsiveness in the emergency department?

Authors:  Silke de Valk; Tycho Joan Olgers; Mirjam Holman; Farouq Ismael; Jack Johannes Maria Ligtenberg; Jan Cornelis Ter Maaten
Journal:  BMC Anesthesiol       Date:  2014-12-12       Impact factor: 2.217

9.  A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness.

Authors:  Yunfan Wu; Shusheng Zhou; Zhihua Zhou; Bao Liu
Journal:  Crit Care       Date:  2014-05-27       Impact factor: 9.097

10.  Measurement of the vascular pedicle width predicts fluid repletion: a cross-sectional comparison with inferior vena cava ultrasound and lung comets.

Authors:  Nawal Salahuddin; Iqbal Hussain; Hakam Alsaidi; Quratulain Shaikh; Mini Joseph; Hassan Hawa; Khalid Maghrabi
Journal:  J Intensive Care       Date:  2015-12-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.