Literature DB >> 21594567

Immobilization and catheter guidance for breast brachytherapy.

A Pompeu-Robinson1, M Kunz, C B Falkson, L J Schreiner, C P Joshi, G Fichtinger.   

Abstract

PURPOSE: Brachytherapy is an important mode of breast cancer treatment; however, improvements in both treatment planning and delivery are needed. In order to meet these specific needs, integration of pre-operative imaging, supplemented by computerized surgical planning and mathematical optimization were used to develop and test an intra-operative immobilization and catheter guidance system.
METHOD: A custom template specific to each patient with optimally placed guide holes for catheter insertion was designed and fabricated. Creation of the template is based on a virtual reality reconstruction of the patient's anatomy from computed tomography imaging. The template fits on the patient's breast, immobilizing the soft tissue, and provides pre-planned catheter insertion holes for guidance to the tumor site. Agar-based phantom and target models were used for quantitative validation of the template by ascertaining the precision and accuracy of the templates.
RESULTS: Tests were performed on agar-based tissue models using computed tomography imaging for template planning and validation. Planned catheter tracks were compared to post-insertion image data and distance measurements from target location were used to create an error measure. Initial results yielded an average error of 4.5mm. Once the workflow and template design were improved, an average error of 2.6mm was observed, bringing the error close to a clinically acceptable range.
CONCLUSION: Use of a patient-specific template for breast brachytherapy is feasible and may improve the procedure accuracy and outcome.

Entities:  

Mesh:

Year:  2011        PMID: 21594567     DOI: 10.1007/s11548-011-0600-6

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  11 in total

1.  Rapid prototype patient-specific drill template for cervical pedicle screw placement.

Authors:  Brent D Owen; Gary E Christensen; Joseph M Reinhardt; Timothy C Ryken
Journal:  Comput Aided Surg       Date:  2007-09

2.  Patient-specific approach in total knee arthroplasty.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams
Journal:  Orthopedics       Date:  2008-09       Impact factor: 1.390

3.  Interfraction and intrafraction setup variability for prone breast radiation therapy.

Authors:  James Mitchell; Silvia C Formenti; J Keith DeWyngaert
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-11-10       Impact factor: 7.038

4.  Computer assisted orthopaedic surgery with image based individual templates.

Authors:  K Radermacher; F Portheine; M Anton; A Zimolong; G Kaspers; G Rau; H W Staudte
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

5.  Immobilizing and Positioning Patients for Radiotherapy.

Authors: 
Journal:  Semin Radiat Oncol       Date:  1995-04       Impact factor: 5.934

6.  Computer-assisted total knee arthroplasty using patient-specific templating.

Authors:  M A Hafez; K L Chelule; B B Seedhom; K P Sherman
Journal:  Clin Orthop Relat Res       Date:  2006-03       Impact factor: 4.176

7.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

8.  The prone technique for breast irradiation - is it ready for clinical trials?

Authors:  Rory McKinnon; David Christie; Helen Peres; Marie Burke; Thai Le; Minjae Lah
Journal:  Breast       Date:  2008-11-17       Impact factor: 4.380

9.  Computer-assisted hip resurfacing using individualized drill templates.

Authors:  Manuela Kunz; John F Rudan; George L Xenoyannis; Randy E Ellis
Journal:  J Arthroplasty       Date:  2009-05-22       Impact factor: 4.757

10.  Rapid fabrication of custom patient biopsy guides.

Authors:  Didier A Rajon; Frank J Bova; Yueh-Yun Chi; William A Friedman
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

View more
  1 in total

1.  Evaluation of PC-ISO for customized, 3D Printed, gynecologic 192-Ir HDR brachytherapy applicators.

Authors:  J Adam M Cunha; Katherine Mellis; Rajni Sethi; Timmy Siauw; Atchar Sudhyadhom; Animesh Garg; Ken Goldberg; I-Chow Hsu; Jean Pouliot
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

  1 in total