Literature DB >> 21592811

Thoratec paracorporeal biventricular assist device therapy: the Freiburg experience.

Kerstin Brehm1, Claudia Heilmann, Matthias Siepe, Christoph Benk, Friedhelm Beyersdorf, Christian Schlensak.   

Abstract

OBJECTIVE: The treatment of severe biventricular (BV) contractile failure using mechanical circulatory support is challenging. We analyzed our center's results following implantation of a biventricular assist device (BVAD).
METHODS: We implanted 39 BVADs between September 2001 and January 2009. All patients were qualified candidates for heart transplantation, without an organ available at time of BVAD implantation. Fifteen patients without a history of chronic cardiomyopathy suffered from acute BV failure (group 1), whereas the other 24 suffered from severe chronic cardiomyopathy (group 2). The indication for BVAD implantation was determined in reference to echocardiography, the degree of end-organ damage, and whether the patient qualified for a heart transplant or was a candidate for bridge to recovery.
RESULTS: Both groups were similar regarding their preoperative hemodynamics, intraoperative and early postoperative findings, and adverse events. Patients in group 1 were younger (mean age 37±17 years) than those in group 2 (51±12 years). Mean duration of support in group 1 was 137±109 days, and 65±61 days in group 2. In group 1, 33% (5/15) were weaned off the device and 53% (8/15) underwent heart transplantation, whereas 8/24 patients (42%) in the chronic group were transplanted. Group 1's mortality on the device was lower than that of group 2 (13% vs 67%). Furthermore, 11 patients of group 1 survived for 1 year compared with four in group 2 (73% vs 17%).
CONCLUSION: Implantation of a BVAD in patients with chronic heart failure and acute decompensation is associated with a high mortality and morbidity rate. By contrast, BVAD implantation can achieve excellent results in patients with acute BV failure without a history of chronic cardiomyopathy, even if they are in cardiogenic shock upon admission.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21592811      PMCID: PMC3241088          DOI: 10.1016/j.ejcts.2011.04.002

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  23 in total

1.  Bridging to cardiac transplantation with the Thoratec Ventricular Assist Device.

Authors:  A El-Banayosy; R Körfer; L Arusoglu; K Minami; L Kizner; O Fey; U Schütt; M Morshuis
Journal:  Thorac Cardiovasc Surg       Date:  1999-02       Impact factor: 1.827

2.  Mechanical Circulatory Support Device Database of the International Society for Heart and Lung Transplantation: second annual report--2004.

Authors:  Mario C Deng; Leah B Edwards; Marshall I Hertz; Amanda W Rowe; Berkeley M Keck; Robert Kormos; David C Naftel; James K Kirklin
Journal:  J Heart Lung Transplant       Date:  2004-09       Impact factor: 10.247

3.  Biventricular assist device utilization for patients with morbid congestive heart failure: a justifiable strategy.

Authors:  Hiroyuki Tsukui; Jeffrey J Teuteberg; Srinivas Murali; Dennis M McNamara; Julianne R Buchanan; Stephen Winowich; Eileen Stanford; Michael A Mathier; Linda M Cadaret; Robert L Kormos
Journal:  Circulation       Date:  2005-08-30       Impact factor: 29.690

4.  Right-to-left ventricular end-diastolic diameter ratio and prediction of right ventricular failure with continuous-flow left ventricular assist devices.

Authors:  Marian Kukucka; Alexander Stepanenko; Evgenij Potapov; Thomas Krabatsch; Mathias Redlin; Alexander Mladenow; Hermann Kuppe; Roland Hetzer; Helmut Habazettl
Journal:  J Heart Lung Transplant       Date:  2010-10-29       Impact factor: 10.247

5.  Preoperative and postoperative comparison of patients with univentricular and biventricular support with the thoratec ventricular assist device as a bridge to cardiac transplantation.

Authors:  D J Farrar; J D Hill; D G Pennington; L R McBride; W L Holman; R L Kormos; D Esmore; L A Gray; P E Seifert; G P Schoettle; C H Moore; P J Hendry; J N Bhayana
Journal:  J Thorac Cardiovasc Surg       Date:  1997-01       Impact factor: 5.209

6.  Mechanical bridge to transplantation: when is too early? When is too late?

Authors:  D Y Loisance; F Pouillart; C Benvenuti; P H Deleuze; J P Mazzucotelli; P Le Besnerais; A Mourtada
Journal:  Ann Thorac Surg       Date:  1996-01       Impact factor: 4.330

7.  The thoratec ventricular assist device: a paracorporeal pump for treating acute and chronic heart failure.

Authors:  D J Farrar
Journal:  Semin Thorac Cardiovasc Surg       Date:  2000-07

8.  Preoperative predictors of survival in patients with Thoratec ventricular assist devices as a bridge to heart transplantation. Thoratec Ventricular Assist Device Principal Investigators.

Authors:  D J Farrar
Journal:  J Heart Lung Transplant       Date:  1994 Jan-Feb       Impact factor: 10.247

9.  Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients.

Authors:  Yoshie Ochiai; Patrick M McCarthy; Nicholas G Smedira; Michael K Banbury; Jose L Navia; Jingyuan Feng; Amy P Hsu; Michael L Yeager; Tiffany Buda; Katherine J Hoercher; Michael W Howard; Masami Takagaki; Kazuyoshi Doi; Kiyotaka Fukamachi
Journal:  Circulation       Date:  2002-09-24       Impact factor: 29.690

10.  Mechanical circulatory support and heart transplantation. Pre-operative status and outcome.

Authors:  A Schiessler; N Friedel; Y Weng; U Heinz; M Hummel; R Hetzer
Journal:  ASAIO J       Date:  1994 Jul-Sep       Impact factor: 2.872

View more
  1 in total

1.  Current perspectives on mechanical circulatory support.

Authors:  Rene Schramm; Michiel Morshuis; Michael Schoenbrodt; Jochen Boergermann; Kavous Hakim-Meibodi; Masatoshi Hata; Jan F Gummert
Journal:  Eur J Cardiothorac Surg       Date:  2019-06-01       Impact factor: 4.191

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.