PCATMIP: enhancing signal intensity in diffusion-weighted magnetic resonance imaging.

V M Pai1, S Rapacchi, P Kellman, P Croisille, H Wen.   

Abstract

Diffusion-weighted MRI studies generally lose signal intensity to physiological motion, which can adversely affect quantification/diagnosis. Averaging over multiple repetitions, often used to improve image quality, does not eliminate the signal loss. In this article, PCATMIP, a combined principal component analysis and temporal maximum intensity projection approach, is developed to address this problem. Data are first acquired for a fixed number of repetitions. Assuming that physiological fluctuations of image intensities locally are likely temporally correlated unlike random noise, a local moving boxcar in the spatial domain is used to reconstruct low-noise images by considering the most relevant principal components in the temporal domain. Subsequently, a temporal maximum intensity projection yields a high signal-intensity image. Numerical and experimental studies were performed for validation and to determine optimal parameters for increasing signal intensity and minimizing noise. Subsequently, a combined principal component analysis and temporal maximum intensity projection approach was used to analyze diffusion-weighted porcine liver MRI scans. In these scans, the variability of apparent diffusion coefficient values among repeated measurements was reduced by 59% relative to averaging, and there was an increase in the signal intensity with higher intensity differences observed at higher b-values. In summary, a combined principal component analysis and temporal maximum intensity projection approach is a postprocessing approach that corrects for bulk motion-induced signal loss and improves apparent diffusion coefficient measurement reproducibility.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21590803      PMCID: PMC3134583          DOI: 10.1002/mrm.22748

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  A novel local PCA-based method for detecting activation signals in fMRI.

Authors:  S H Lai; M Fang
Journal:  Magn Reson Imaging       Date:  1999-07       Impact factor: 2.546

2.  Improving image contrast using principal component analysis for subsequent image segmentation.

Authors:  Y Zhang; A Goldszal; J Butman; P Choyke
Journal:  J Comput Assist Tomogr       Date:  2001 Sep-Oct       Impact factor: 1.826

3.  Generalizable patterns in neuroimaging: how many principal components?

Authors:  L K Hansen; J Larsen; F A Nielsen; S C Strother; E Rostrup; R Savoy; N Lange; J Sidtis; C Svarer; O B Paulson
Journal:  Neuroimage       Date:  1999-05       Impact factor: 6.556

4.  Construction of a statistical model for cardiac motion analysis using nonrigid image registration.

Authors:  Raghavendra Chandrashekara; Anil Rao; Gerardo Ivar Sanchez-Ortiz; Raad H Mohiaddin; Daniel Rueckert
Journal:  Inf Process Med Imaging       Date:  2003-07

5.  Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging.

Authors:  Peter Kellman; Christophe Chefd'hotel; Christine H Lorenz; Christine Mancini; Andrew E Arai; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

6.  The influence of flow and motion in MRI of diffusion using a modified CE-FAST sequence.

Authors:  K D Merboldt; W Hänicke; M L Gyngell; J Frahm; H Bruhn
Journal:  Magn Reson Med       Date:  1989-11       Impact factor: 4.668

7.  The utility of principal component analysis for the image display of brain lesions. A preliminary, comparative study.

Authors:  U Schmiedl; D A Ortendahl; A S Mark; I Berry; L Kaufman
Journal:  Magn Reson Med       Date:  1987-05       Impact factor: 4.668

8.  Motionless movies of myocardial strain-rates using stimulated echoes.

Authors:  V J Wedeen; R M Weisskoff; T G Reese; G M Beache; B P Poncelet; B R Rosen; R E Dinsmore
Journal:  Magn Reson Med       Date:  1995-03       Impact factor: 4.668

9.  In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging.

Authors:  Bashar Issa
Journal:  J Magn Reson Imaging       Date:  2002-08       Impact factor: 4.813

10.  Making the most of fMRI at 7 T by suppressing spontaneous signal fluctuations.

Authors:  Marta Bianciardi; Peter van Gelderen; Jeff H Duyn; Masaki Fukunaga; Jacco A de Zwart
Journal:  Neuroimage       Date:  2008-09-12       Impact factor: 6.556

View more
  12 in total

1.  Quantifying precision in cardiac diffusion tensor imaging with second-order motion-compensated convex optimized diffusion encoding.

Authors:  Eric Aliotta; Kévin Moulin; Patrick Magrath; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

2.  Assessment of cardiac motion effects on the fiber architecture of the human heart in vivo.

Authors:  Hongjiang Wei; Magalie Viallon; Benedicte M A Delattre; Lihui Wang; Vinay M Pai; Han Wen; Hui Xue; Christoph Guetter; Pierre Croisille; Yuemin Zhu
Journal:  IEEE Trans Med Imaging       Date:  2013-06-19       Impact factor: 10.048

3.  Low b-value diffusion-weighted cardiac magnetic resonance imaging: initial results in humans using an optimal time-window imaging approach.

Authors:  Stanislas Rapacchi; Han Wen; Magalie Viallon; Denis Grenier; Peter Kellman; Pierre Croisille; Vinay M Pai
Journal:  Invest Radiol       Date:  2011-12       Impact factor: 6.016

4.  Error model for reduction of cardiac and respiratory motion effects in quantitative liver DW-MRI.

Authors:  Paul Murphy; Tanya Wolfson; Anthony Gamst; Claude Sirlin; Mark Bydder
Journal:  Magn Reson Med       Date:  2012-12-27       Impact factor: 4.668

5.  In vivo cardiac diffusion-weighted magnetic resonance imaging: quantification of normal perfusion and diffusion coefficients with intravoxel incoherent motion imaging.

Authors:  Benedicte M A Delattre; Magalie Viallon; Hongjiang Wei; Yuemin M Zhu; Thorsten Feiweier; Vinay M Pai; Han Wen; Pierre Croisille
Journal:  Invest Radiol       Date:  2012-11       Impact factor: 6.016

6.  An in-vivo comparison of stimulated-echo and motion compensated spin-echo sequences for 3 T diffusion tensor cardiovascular magnetic resonance at multiple cardiac phases.

Authors:  Andrew D Scott; Sonia Nielles-Vallespin; Pedro F Ferreira; Zohya Khalique; Peter D Gatehouse; Philip Kilner; Dudley J Pennell; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2018-01-03       Impact factor: 5.364

7.  Complex diffusion-weighted image estimation via matrix recovery under general noise models.

Authors:  Lucilio Cordero-Grande; Daan Christiaens; Jana Hutter; Anthony N Price; Jo V Hajnal
Journal:  Neuroimage       Date:  2019-06-18       Impact factor: 6.556

8.  Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart.

Authors:  Constantin von Deuster; Christian T Stoeck; Martin Genet; David Atkinson; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2015-10-07       Impact factor: 4.668

9.  Bayesian intravoxel incoherent motion parameter mapping in the human heart.

Authors:  Georg R Spinner; Constantin von Deuster; Kerem C Tezcan; Christian T Stoeck; Sebastian Kozerke
Journal:  J Cardiovasc Magn Reson       Date:  2017-11-06       Impact factor: 5.364

10.  Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: An accurate and precise clinically feasible protocol.

Authors:  Oliver J Gurney-Champion; Susanne S Rauh; Kevin Harrington; Uwe Oelfke; Frederik B Laun; Andreas Wetscherek
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.