Comparison of different dosimetric methods for red marrow absorbed dose calculation in thyroid cancer therapy.

José Willegaignon1, Marcelo T Sapienza, Carlos A Buchpiguel.   

Abstract

Several dosimetric methods have been proposed for estimating red marrow absorbed dose (RMAD) when radionuclide therapy is planned for differentiated thyroid cancer, although to date, there is no consensus as to whether dose calculation should be based on blood-activity concentration or not. Our purpose was to compare RMADs derived from methods that require collecting patients' blood samples versus those involving OLINDA/EXM software, thereby precluding this invasive procedure. This is a retrospective study that included 34 patients under treatment for metastatic thyroid disease. A deviation of <10 % between RMADs was found, when comparing the doses from the most usual invasive dosimetric methods and those from OLINDA/EXM. No statistical difference between the methods was discovered, whereby the need for invasive procedures when calculating the dose is questioned. The use of OLINDA/EXM in clinical routine could possibly diminish data collection, thus giving rise to a simultaneous reduction in time and clinical costs, besides avoiding any kind of discomfort on the part of the patients involved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21586539     DOI: 10.1093/rpd/ncr214

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Red bone marrow dose estimation using several internal dosimetry models for prospective dosimetry-oriented radioiodine therapy.

Authors:  Mohammad Abuqbeitah; Mustafa Demir; İffet Çavdar; Handan Tanyildizi; Nami Yeyin; Lebriz Uslu-Beşli; Levent Kabasakal; Nazenin İpek Işıkcı; Kerim Sönmezoğlu
Journal:  Radiat Environ Biophys       Date:  2018-10-08       Impact factor: 1.925

2.  Estimating (131)I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification.

Authors:  José Willegaignon; Rogério Alexandre Pelissoni; Beatriz Christine de Godoy Diniz Lima; Marcelo Tatit Sapienza; George Barberio Coura-Filho; Marcelo Araújo Queiroz; Carlos Alberto Buchpiguel
Journal:  Radiol Bras       Date:  2016 May-Jun

Review 3.  Radionuclide therapy: current status and prospects for internal dosimetry in individualized therapeutic planning.

Authors:  Marcelo Tatit Sapienza; José Willegaignon
Journal:  Clinics (Sao Paulo)       Date:  2019-07-29       Impact factor: 2.365

4.  A practical method of I-131 thyroid cancer therapy dose optimization using estimated effective renal clearance.

Authors:  Brandon A Howard; Olga G James; Jennifer M Perkins; Robert A Pagnanelli; Salvador Borges-Neto; Robert E Reiman