Evaluation of the Beckman Coulter UniCel DxH 800, Beckman Coulter LH 780, and Abbott Diagnostics Cell-Dyn Sapphire hematology analyzers on adult specimens in a tertiary care hospital.

Brent T Tan1, Armando J Nava, Tracy I George.   

Abstract

We evaluated the new Beckman Coulter DxH 800 hematology analyzer (Beckman Coulter, Miami, FL) vs the Abbott Diagnostics Cell-Dyn Sapphire (Abbott Diagnostics, Santa Clara, CA) and Beckman Coulter LH 780 hematology analyzers using 430 adult specimens. The DxH 800 provided a CBC and differential that correlated well with those of the Sapphire and LH 780, with most parameters showing correlation coefficients (r) of more than 0.97. In the instrument vs 400-cell manual differential comparison, all 3 instruments showed similar and acceptable accuracy to the reference method except for nucleated RBC (NRBC) enumeration, in which the DxH 800 and Sapphire outperformed the LH 780. We also compared clinical efficiency by determining whether flagged specimens showed abnormalities on a peripheral blood smear as defined by International Council for Standardization in Haematology criteria. The efficiency, sensitivity, and specificity of the DxH 800 were 77.0%, 87.1%, and 73.0%, respectively, compared with the Sapphire at 75.8%, 93.5%, and 68.8%, respectively, and LH 780 at 66.1%, 93.5%, and 55.3%, respectively.

Entities:  

Mesh:

Year:  2011        PMID: 21571967     DOI: 10.1309/AJCP1V3UXEIQTSLE

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  8 in total

1.  Validation rules for blood smear revision after automated hematological testing using Mindray CAL-8000.

Authors:  Sabrina Buoro; Tommaso Mecca; Michela Seghezzi; Barbara Manenti; Giovanna Azzarà; Cosimo Ottomano; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2016-10-06       Impact factor: 2.352

2.  A comparison of Sysmex-XN 2000 and Yumizen H2500 automated hematology analyzers.

Authors:  Milena Małecka; Olga Ciepiela
Journal:  Pract Lab Med       Date:  2020-10-29

3.  Overall equipment effectiveness, efficiency and slide review analysis of high-end hematology analyzers.

Authors:  Shubham Rastogi; Sukesh Chandran Nair; Pandiyan Murugan; Asady Sukanya Sukumar; Joy J Mammen; Saravanan Mullai
Journal:  Pract Lab Med       Date:  2022-04-18

4.  A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.

Authors:  Olga Ciepiela; Iwona Kotuła; Szymon Kierat; Sandra Sieczkowska; Anna Podsiadłowska; Anna Jenczelewska; Karolina Księżarczyk; Urszula Demkow
Journal:  J Clin Lab Anal       Date:  2016-05-17       Impact factor: 2.352

5.  Changes of hematological references depends on storage period and temperature conditions in rats and dogs.

Authors:  Jung-Min Lee; Jin Seok Kang
Journal:  Lab Anim Res       Date:  2016-12-23

6.  Association of hematological indices with prediabetes: A cross-sectional study.

Authors:  Amir Ziaee; Azam Ghorbani; Saied Kalbasi; Alireza Hejrati; Saba Moradi
Journal:  Electron Physician       Date:  2017-09-25

7.  The effect of consumption of garlic tablet on proteins oxidation biomarkers in postmenopausal osteoporotic women: A randomized clinical trial.

Authors:  Fereshte Ahmadian; Hassan Mozaffari-Khosravi; Mohammad Hossein Azaraein; Reza Faraji; Javad Zavar-Reza
Journal:  Electron Physician       Date:  2017-11-25

8.  Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.

Authors:  Jérôme Allardet-Servent; Melissa Lebsir; Christian Dubroca; Martine Fabrigoule; Sylvie Jordana; Thomas Signouret; Matthias Castanier; Guillemette Thomas; Rettinavelou Soundaravelou; Anne Lepidi; Laurence Delapierre; Guillaume Penaranda; Philippe Halfon; Jean-Marie Seghboyan
Journal:  PLoS One       Date:  2017-01-10       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.