Literature DB >> 21569842

Development of a Process Analytical Technology (PAT) for in-line monitoring of film thickness and mass of coating materials during a pan coating operation.

Claire Gendre1, Muriel Genty, Mathieu Boiret, Marc Julien, Loïc Meunier, Olivier Lecoq, Michel Baron, Pierre Chaminade, Jean Manuel Péan.   

Abstract

The aim of this study was to perform in-line Near Infrared (NIR) measurements inside a pan coater to monitor a coating operation in real-time, by predicting the increases in mass of coating materials and coating thickness. A polymer combination of ethylcellulose/poly(vinyl-alcohol)-poly(ethylene-glycol) graft copolymer was used as functional aqueous coating. Coated tablets were sampled at regular intervals during the coating operation, then subjected to either simple and fast weighing (n=50) or accurate and non-destructive Terahertz Pulsed Imaging (TPI) measurements (n=3). Off-line NIR spectra analysis revealed that the coating operation could efficiently be controlled by focusing on two distinct NIR regions, related to absorption bands of ethylcellulose. Principal component analysis of in-line NIR spectra gave a clear classification of the collected coated tablets. Real-time quantitative monitoring of the coating operation was successfully performed from partial least square calibration models built using either TPI or weighing as reference method. Coating thicknesses as well as mass of coating materials used as primary values provided accurate NIR predictions. A comparison study demonstrated that both reference methods led to reliable and accurate real-time monitoring of the coating operation. This work demonstrated that in-line NIR measurements associated with multivariate analyses can be implemented to monitor in real-time a pan coating operation in order to fulfil the expectations of ICH Q8 guideline on pharmaceutical development, especially in terms of PAT control strategy and reduced end-product testing.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21569842     DOI: 10.1016/j.ejps.2011.04.017

Source DB:  PubMed          Journal:  Eur J Pharm Sci        ISSN: 0928-0987            Impact factor:   4.384


  5 in total

Review 1.  Solvent-free melting techniques for the preparation of lipid-based solid oral formulations.

Authors:  Karin Becker; Sharareh Salar-Behzadi; Andreas Zimmer
Journal:  Pharm Res       Date:  2015-03-19       Impact factor: 4.200

2.  Feasibility of In-line monitoring of critical coating quality attributes via OCT: Thickness, variability, film homogeneity and roughness.

Authors:  Stephan Sacher; Anna Peter; Johannes G Khinast
Journal:  Int J Pharm X       Date:  2020-12-17

Review 3.  Pharmaceutical application of multivariate modelling techniques: a review on the manufacturing of tablets.

Authors:  Guolin Shi; Longfei Lin; Yuling Liu; Gongsen Chen; Yuting Luo; Yanqiu Wu; Hui Li
Journal:  RSC Adv       Date:  2021-02-23       Impact factor: 3.361

Review 4.  Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification.

Authors:  Eun Ji Kim; Ji Hyeon Kim; Min-Soo Kim; Seong Hoon Jeong; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2021-06-21       Impact factor: 6.321

Review 5.  Review of Terahertz Pulsed Imaging for Pharmaceutical Film Coating Analysis.

Authors:  Décio Alves-Lima; Jun Song; Xiaoran Li; Alessia Portieri; Yaochun Shen; J Axel Zeitler; Hungyen Lin
Journal:  Sensors (Basel)       Date:  2020-03-06       Impact factor: 3.576

  5 in total