Literature DB >> 21550762

Knee simulator wear of vitamin E stabilized irradiated ultrahigh molecular weight polyethylene.

Brad R Micheli1, Keith K Wannomae, Andrew J Lozynsky, Steven D Christensen, Orhun K Muratoglu.   

Abstract

Wear and damage of ultrahigh molecular weight polyethylene (UHMWPE) tibial inserts used in total knee arthroplasty are accelerated by oxidation. Radiation crosslinking reduces wear but produces residual free radicals adversely affecting stability. One alternative to stabilize radiation-crosslinked UHMWPE is to infuse the material with vitamin E (vit E). We investigated the properties of 100-kGy e-beam-irradiated UHMWPE that was subsequently doped with vitamin E in comparison with conventional UHMWPE. Both polymers were sterilized with gamma irradiation in vacuum packaging. Vitamin E-doped UHMWPE showed lower wear before and after aging (2.4 ± 0.5 and 2.5 ± 0.8 mg/million cycle, respectively, vs 26.9 ± 3.5 and 40.8 ± 3.0 mg/million cycle for conventional UHMWPE). Conventional UHMWPE showed oxidation after accelerated aging, and its mechanical properties were adversely affected, whereas vit E-doped UHMWPE showed no oxidation or changes in its mechanical properties. Vitamin E stabilization of radiation-crosslinked UHMWPE resulted in low wear and high oxidation resistance; it is an alternative load-bearing material for total knee applications.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21550762     DOI: 10.1016/j.arth.2011.03.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Retrieval analysis of contemporary antioxidant polyethylene: multiple material and design changes may decrease implant performance.

Authors:  Arianna Cerquiglini; Johann Henckel; Harry Hothi; Lukas B Moser; Antti Eskelinen; Michael T Hirschmann; Alister J Hart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-02-10       Impact factor: 4.342

2.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

3.  Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty.

Authors:  Hannah Spece; Jaclyn T Schachtner; Daniel W MacDonald; Gregg R Klein; Michael A Mont; Gwo-Chin Lee; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2019-07-18       Impact factor: 4.757

Review 4.  Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review.

Authors:  Antonio Gigante; Carlo Bottegoni; Vincenza Ragone; Lorenzo Banci
Journal:  J Funct Biomater       Date:  2015-09-08

5.  Future bearing surfaces in total hip arthroplasty.

Authors:  Jun-Dong Chang
Journal:  Clin Orthop Surg       Date:  2014-02-14

6.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

7.  Comparative retrieval analysis of antioxidant polyethylene: bonding of vitamin-E does not reduce in-vivo surface damage.

Authors:  Dominic T Mathis; Joshua Schmidli; Michael T Hirschmann; Felix Amsler; Johann Henckel; Harry Hothi; Alister Hart
Journal:  BMC Musculoskelet Disord       Date:  2021-11-30       Impact factor: 2.362

8.  Influence of Accelerated Aging on the Wear Behavior of Cross-Linked Polyethylene Liners-A Hip Simulator Study.

Authors:  Rebecca H Dammer; Carmen Zietz; Jörn Reinders; Michael Teske; Rainer Bader
Journal:  J Clin Med       Date:  2022-08-01       Impact factor: 4.964

9.  Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator.

Authors:  Saverio Affatato; Alessandro Ruggiero; Sami Abdel Jaber; Massimiliano Merola; Pierangiola Bracco
Journal:  Materials (Basel)       Date:  2018-03-16       Impact factor: 3.623

  9 in total