Literature DB >> 21550741

Diffusion-weighted imaging of the brain at 7 T with echo-planar and turbo spin echo sequences: preliminary results.

Eric E Sigmund1, David Gutman.   

Abstract

Ultra-high-field clinical MRI scanners (e.g., 7 T and above) are becoming increasingly prevalent and can potentially enhance diagnostic ability through higher contrast, resolution and/or sensitivity. Diffusion-weighted MRI is a highly valued component in today's radiological exam and may benefit from the enhanced signal-to-noise ratio provided by high field with the appropriate imaging strategy. The most common diffusion pulse sequence readout (echo-planar imaging (EPI)) has been widely employed for in vivo human 7 T diffusion tensor imaging (DTI). In this article, we present results of brain DTI at 7 T with two diffusion-weighted imaging pulse sequence readouts: echo-planar imaging (EPI-DTI) and turbo spin echo (TSE-DTI). Results indicate that analogous coverage, quality and resolution typical of lower field (2 mm) can be obtained by properly processed EPI-DTI at 7 T, and, with some reduction in efficiency and sharpness, TSE-DTI at 7 T. Furthermore, 7 T TSE-DTI shows promise in obtaining higher-resolution results in targeted acquisitions of specific brain areas.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21550741     DOI: 10.1016/j.mri.2011.02.016

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Diffusivity of intraorbital lymphoma vs. inflammation: comparison of single shot turbo spin echo and multishot echo planar imaging techniques.

Authors:  Akio Hiwatashi; Osamu Togao; Koji Yamashita; Kazufumi Kikuchi; Ryotaro Kamei; Hiroshi Yoshikawa; Atsushi Takemura; Hiroshi Honda
Journal:  Eur Radiol       Date:  2017-08-04       Impact factor: 5.315

2.  Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.

Authors:  Priti Balchandani; Deqiang Qiu
Journal:  Magn Reson Imaging       Date:  2014-04-13       Impact factor: 2.546

3.  Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma.

Authors:  Ekim Gumeler; Safak Parlak; Gozde Yazici; Erdem Karabulut; Hayyam Kiratli; Kader K Oguz
Journal:  Br J Radiol       Date:  2020-12-22       Impact factor: 3.039

4.  A Comparison of 3 T and 7 T MRI for the Clinical Evaluation of Uveal Melanoma.

Authors:  Michael C Y Tang; Myriam G Jaarsma-Coes; Teresa A Ferreira; Lorna Zwirs-Grech Fonk; Marina Marinkovic; Gregorius P M Luyten; Jan-Willem M Beenakker
Journal:  J Magn Reson Imaging       Date:  2021-10-15       Impact factor: 5.119

5.  Portable, low-field magnetic resonance imaging enables highly accessible and dynamic bedside evaluation of ischemic stroke.

Authors:  Matthew M Yuen; Anjali M Prabhat; Mercy H Mazurek; Isha R Chavva; Anna Crawford; Bradley A Cahn; Rachel Beekman; Jennifer A Kim; Kevin T Gobeske; Nils H Petersen; Guido J Falcone; Emily J Gilmore; David Y Hwang; Adam S Jasne; Hardik Amin; Richa Sharma; Charles Matouk; Adrienne Ward; Joseph Schindler; Lauren Sansing; Adam de Havenon; Ani Aydin; Charles Wira; Gordon Sze; Matthew S Rosen; W Taylor Kimberly; Kevin N Sheth
Journal:  Sci Adv       Date:  2022-04-20       Impact factor: 14.957

6.  Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.

Authors:  Filip Szczepankiewicz; Jens Sjölund; Freddy Ståhlberg; Jimmy Lätt; Markus Nilsson
Journal:  PLoS One       Date:  2019-03-28       Impact factor: 3.240

  6 in total