Literature DB >> 33264035

Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma.

Ekim Gumeler1, Safak Parlak1, Gozde Yazici2, Erdem Karabulut3, Hayyam Kiratli4, Kader K Oguz1.   

Abstract

OBJECTIVES: Diffusion weighted imaging (DWI) has become important for orbital imaging. However, the echoplanar imaging (EPI) DWI has inherent obstacles due to susceptibility to magnetic field inhomogeneities. We conducted a comparative study assessing the image quality of orbits in a patient cohort with uveal melanoma (UM). We hypothesized that single shot turbo spin echo (ssTSE) DWI would have better image quality in terms of less distortion and artifacts and yield better tissue evaluation compared to ssEPI-DWI.
METHODS: ssEPI-DWI and ssTSE-DWI of orbits were obtained from 50 patients with uveal melanoma who were prospectively enrolled in the study. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diffusion signal properties, and apparent diffusion coefficient (ADC) values were collected and compared between ssEPI-DWI and ssTSE-DWI. Two reviewers evaluated and compared the geometric distortion, susceptibility and ghosting artifacts, resolution, demarcation of ocular mass, and overall quality.
RESULTS: A higher DR was found in ssEPI-DWI compared to ssTSE-DWI (p < 0.001). SNR and CNR were lower for the temporal lobe cortex (p ≤ 0.004), but higher for melanoma in ssEPI-DWI than ssTSE-DWI (p ≤ 0.037). Geometric distortion and artifacts were more common in ssEPI-DWI (p < 0.001). Resolution (p ≤ 0.013) and overall quality (p < 0.001) were better in ssTSE-DWI. Ocular masses were demarcated better on ssEPI-DWI (p ≤ 0.002). Significant negative correlations between T1 and T2 signal intensities (r = -0.369, p ≤ 0.008) and positive correlations between T2 and both DWI signal intensities (r = 0.686 and p < 0.001 for ssEPI-DWI, r = 0.747 and p < 0.001 for ssTSE-DWI) were revealed.
CONCLUSION: With less geometric distortion and susceptibility artifacts, better resolution, and overall quality, ssTSE-DWI can serve as an alternative to ssEPI-DWI for orbital DWI. ADVANCES IN KNOWLEDGE: ssTSE-DWI can be a better alternative of diffusion imaging of orbits with less susceptibility artifact and geometric distortion compared to ssEPI-DWI.

Entities:  

Mesh:

Year:  2020        PMID: 33264035      PMCID: PMC7934310          DOI: 10.1259/bjr.20200825

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  35 in total

Review 1.  Principles and applications of echo-planar imaging: a review for the general radiologist.

Authors:  M Poustchi-Amin; S A Mirowitz; J J Brown; R C McKinstry; T Li
Journal:  Radiographics       Date:  2001 May-Jun       Impact factor: 5.333

2.  Differentiation between benign and malignant orbital tumors at 3-T diffusion MR-imaging.

Authors:  Ahmed Abdel Khalek Abdel Razek; Sahar Elkhamary; Amani Mousa
Journal:  Neuroradiology       Date:  2011-02-01       Impact factor: 2.804

3.  Noise measurement and estimation in MR imaging experiments.

Authors:  Johannes T Heverhagen
Journal:  Radiology       Date:  2007-12       Impact factor: 11.105

4.  Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck.

Authors:  Ryoji Mikayama; Hidetake Yabuuchi; Shinjiro Sonoda; Koji Kobayashi; Kazuya Nagatomo; Mitsuhiro Kimura; Satoshi Kawanami; Takeshi Kamitani; Seiji Kumazawa; Hiroshi Honda
Journal:  Eur Radiol       Date:  2017-08-04       Impact factor: 5.315

5.  Diffusion-weighted MR imaging in normal human brains in various age groups.

Authors:  Johanna Helenius; Lauri Soinne; Jussi Perkiö; Oili Salonen; Aki Kangasmäki; Markku Kaste; Richard A D Carano; Hannu J Aronen; Turgut Tatlisumak
Journal:  AJNR Am J Neuroradiol       Date:  2002-02       Impact factor: 3.825

6.  Single-shot turbo spin-echo diffusion-weighted imaging for retinoblastoma: initial experience.

Authors:  P de Graaf; P J W Pouwels; F Rodjan; A C Moll; S M Imhof; D L Knol; E Sanchez; P van der Valk; J A Castelijns
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

7.  Diffusion-weighted imaging of malignant ocular masses: initial results and directions for further study.

Authors:  A R Sepahdari; R Kapur; V K Aakalu; J P Villablanca; M F Mafee
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-24       Impact factor: 3.825

8.  Accuracy of diagnosis of choroidal melanomas in the Collaborative Ocular Melanoma Study. COMS report no. 1.

Authors: 
Journal:  Arch Ophthalmol       Date:  1990-09

9.  Diffusion-weighted imaging of orbital masses: multi-institutional data support a 2-ADC threshold model to categorize lesions as benign, malignant, or indeterminate.

Authors:  A R Sepahdari; L S Politi; V K Aakalu; H J Kim; A A K Abdel Razek
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-18       Impact factor: 3.825

10.  Correlation of MR imaging and histologic findings in mouse melanoma.

Authors:  J O DeJordy; P Bendel; A Horowitz; Y Salomon; H Degani
Journal:  J Magn Reson Imaging       Date:  1992 Nov-Dec       Impact factor: 4.813

View more
  2 in total

1.  Comparison of TGSE-BLADE DWI, RESOLVE DWI, and SS-EPI DWI in healthy volunteers and patients after cerebral aneurysm clipping.

Authors:  Sachi Okuchi; Yasutaka Fushimi; Kazumichi Yoshida; Satoshi Nakajima; Akihiko Sakata; Takuya Hinoda; Sayo Otani; Hajime Sagawa; Kun Zhou; Yukihiro Yamao; Masakazu Okawa; Yuji Nakamoto
Journal:  Sci Rep       Date:  2022-10-21       Impact factor: 4.996

2.  Diffusion-Weighted Imaging Combined with Perfusion-Weighted Imaging under Segmentation Algorithm in the Diagnosis of Melanoma.

Authors:  Chuankui Shi; Peng Ge; Yuping Zhao; Guobao Huang
Journal:  Contrast Media Mol Imaging       Date:  2022-06-27       Impact factor: 3.009

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.