Dear Sir, Particulate matter can be defined as “the mobile, undissolved substances unintentionally present in parenterals.1 A wide variety of particulates have been reported in parenteral solutions, including asbestos fibers, rubber particles, chemical particles, cellulose fibres, fungi, starch, diatoms, and glass particles.2 (“Particulates can enter these solutions in various manners. Many may enter the solutions during processing. There are not universally applicable guidelines, and thus assuming that problem may be of questionable significance. Colloidal particles of a plasticizer, di-2-ethylhexylphthalate (DEHP) have been identified as being present in solutions contained in polyvinylchloride (PVC) bags. Agitation of the bags increased the amount of DEHP delivered, while the addition of ethanol to the solution in the bags so significantly increased the amount of DEHP delivered that Corley,et al. recommended that a warning be included with solutions in PVC bags-” not to compound ethanol solutions in the bags”.3 Recently we encountered a particulate contamination in freshly prepared thiopentone syringe. Three black particles were floating in the syringe and were grossly visible (Fig. 1). After filtering it on the cotton gauge (Fig. 2) the particulate matter seemed to be of black rubber which we thought could have cored either from saline bottle seal or thiopentone vial. But when we examined the saline bottle and thiopentone vial, the colour of their seal was grey. Further looking into the cause it was observed that the particulate has sheared off from the syringe plunger. (Fig. 1 arrow showing the site). Ideally in a good quality syringe this problem should not occur but recycled goods are pumped into market by spurious manufactures which can cause such problem for which responsibility lies on the anaesthesiologist although ultimate sufferer is patient. As from literature syringe plunger can be a source of silicone contamination4 and some time particulate contamination if it is sheared during transfer or aspiration of drug from other syringe with needle.5
Figure 1

Black particulate matter floating in thiopentone syringe and arrow depicting sheared plunger.

Figure 2

Particulates filtered on cotton gauge piece.

Black particulate matter floating in thiopentone syringe and arrow depicting sheared plunger. Particulates filtered on cotton gauge piece. There are many solutions offered to prevent complication from coring. In-line “final” filtration may be the ultimate answer. Davis, et al. report that in-line final filtration appears to be 100% effective in the removal of particulates.6 There is still some question about the value of these filters under routine clinical conditions. The EmulSivTM filter (EF; Pall Biomedical Products Co., East Hill, NY, USA) is a filter specifically created for use with lipid emulsion based drugs like propofol. This 0.45 micron rated filter is purported to provide protection from accidental microbial contamination, particulate contamination and entrained air while maintaining the integrity of the emulsion.7 For the prevention of glass particle contamination in peripheral intravenous admixtures, the use of pre-filled syringe drugs can be a useful method.8 There is no consensus on the problems of and possible solutions to particulate contamination. It is a problem that the anaesthesiologist should be aware of, and exercise reasonable precautions to assure the particulate free drug delivery to patients.
  8 in total

1.  Effect of various factors on the amount of plasticizer in intravenous solutions packaged in flexible bags.

Authors:  J H Corley; T E Needham; E D Sumner; R Mikeal
Journal:  Am J Hosp Pharm       Date:  1977-03

2.  THE HARMFUL EFFECTS OF PARTICLES IN INTRAVENOUS FLUIDS.

Authors:  J M GARVAN; B W GUNNER
Journal:  Med J Aust       Date:  1964-07-04       Impact factor: 7.738

3.  A foreign body in propofol syringe.

Authors:  Shaul Cohen; Narissa Prieto; Christine H Hunter
Journal:  Anesth Analg       Date:  2006-09       Impact factor: 5.108

4.  Particulate and microbial contamination in in-use admixed intravenous infusions.

Authors:  Katsuhiro Yorioka; Shigeharu Oie; Masafumi Oomaki; Akihisa Imamura; Akira Kamiya
Journal:  Biol Pharm Bull       Date:  2006-11       Impact factor: 2.233

5.  Particle contamination in contrast media induced by disposable syringes.

Authors:  T Sendo; K Otsubo; A Hisazumi; T Aoyama; R Oishi
Journal:  J Pharm Sci       Date:  1995-12       Impact factor: 3.534

6.  Particulate matter in small-volume parenterals as determined by two methods.

Authors:  Y S Lim; S Turco; N M Davis
Journal:  Am J Hosp Pharm       Date:  1973-06

7.  Effect of inline filtration of intravenous infusions on the incidence of thrombophlebitis.

Authors:  M E Chamberland; R W Lyons; S M Brock
Journal:  Am J Hosp Pharm       Date:  1977-10

8.  The EmulSiv filter removes microbial contamination from propofol but is not a substitute for aseptic technique.

Authors:  Wendy C E Hall; Donald T Jolly; Jiri Hrazdil; John C Galbraith; Maria Greacen; Alexander S Clanachan
Journal:  Can J Anaesth       Date:  2003 Jun-Jul       Impact factor: 5.063

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.