Literature DB >> 21531465

Biometric analysis of pigment dispersion syndrome using anterior segment optical coherence tomography.

Florent Aptel1, Sylvain Beccat, Vincent Fortoul, Philippe Denis.   

Abstract

PURPOSE: To compare anterior chamber volume (ACV), iris volume, and iridolenticular contact (ILC) area before and after laser peripheral iridotomy (LPI) in eyes with pigment dispersion syndrome (PDS) using anterior segment optical coherence tomography (AS OCT) and image processing software.
DESIGN: Cross-sectional study. PARTICIPANTS: Eighteen eyes of 18 patients with PDS; 30 eyes of 30 controls matched for age, gender, and refraction.
METHODS: Anterior segment OCT imaging was performed in all eyes before LPI and 1, 4, and 12 weeks after LPI. At each visit, 12 cross-sectional images of the AS were taken: 4 in bright conditions with accommodation (accommodation), 4 in bright conditions without accommodation (physiological miosis), and 4 under dark conditions (physiologic mydriasis). Biometric parameters were estimated using AS OCT radial sections and customized image-processing software. MAIN OUTCOME MEASURES: Anterior chamber volume, iris volume-to-length ratio, ILC area, AS OCT anterior chamber depth, and A-scan ultrasonography axial length.
RESULTS: Before LPI, PDS eyes had a significantly greater ACV and ILC area than control eyes (P<0.01) and a significantly smaller iris volume-to-length ratio than the controls (P<0.05). After LPI, ACV and ILC area decreased significantly in PDS eyes, but iris volume-to-length ratio increased significantly (P<0.02) and was not significantly different from that of controls. These biometric changes were stable over time. Iris volume-to-length ratio decreased significantly from accommodation to mydriasis and from miosis to mydriasis, both in PDS and control eyes (P<0.01). In PDS eyes, ILC area decreased significantly from accommodation to mydriasis, both before and after LPI (P<0.01). On multivariate analysis, greater anterior chamber (AC) volume (P<0.02) and larger AC depth (P<0.05) before LPI were significant predictors of a larger ILC area.
CONCLUSIONS: Pigment dispersion syndrome eyes do not have an iris that is abnormally large, relative to the AS size, but have a weakly resistant iris that is stretched and pushed against the lens when there is a pressure difference across the iris. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21531465     DOI: 10.1016/j.ophtha.2011.01.001

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  12 in total

1.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

2.  [Is prophylactic YAG iridotomy useful in pigment dispersion syndrome?].

Authors:  A Rosentreter; O Schwenn; J Funk; T Dietlein
Journal:  Ophthalmologe       Date:  2013-04       Impact factor: 1.059

3.  [Pigment dispersion syndrome and pigmentary glaucoma. Morphometric analysis of the anterior chamber segment with SL-OCT].

Authors:  B Birner; T Tourtas; J M Wessel; A G Jünemann; C Y Mardin; F E Kruse; R Laemmer
Journal:  Ophthalmologe       Date:  2014       Impact factor: 1.059

Review 4.  Image-guided evaluation and monitoring of treatment response in patients with dry eye disease.

Authors:  Yureeda Qazi; Shruti Aggarwal; Pedram Hamrah
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-04       Impact factor: 3.117

5.  Anterior-segment morphology and corneal biomechanical characteristics in pigmentary glaucoma.

Authors:  Annemarie Klingenstein; Marcus Kernt; Florian Seidensticker; Anselm Kampik; Christoph Hirneiss
Journal:  Clin Ophthalmol       Date:  2013-12-24

6.  Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study.

Authors:  Alexander K Schuster; Norbert Pfeiffer; Stefan Nickels; Andreas Schulz; Philipp S Wild; Maria Blettner; Karl Lackner; Manfred E Beutel; Thomas Münzel; Urs Vossmerbaeumer
Journal:  J Ophthalmol       Date:  2017-09-11       Impact factor: 1.909

7.  Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

Authors:  Seung Pil Bang; Choun-Ki Joo; Jong Hwa Jun
Journal:  BMC Ophthalmol       Date:  2017-03-29       Impact factor: 2.209

8.  A transcriptome atlas of the mouse iris at single-cell resolution defines cell types and the genomic response to pupil dilation.

Authors:  Jie Wang; Amir Rattner; Jeremy Nathans
Journal:  Elife       Date:  2021-11-16       Impact factor: 8.140

9.  The role of anterior segment optical coherence tomography in glaucoma.

Authors:  Sarwat Salim
Journal:  J Ophthalmol       Date:  2012-08-01       Impact factor: 1.909

10.  Influence of exercise on the structure of the anterior chamber of the eye.

Authors:  Mu Li; Yinwei Song; Yin Zhao; Xiaoqin Yan; Hong Zhang
Journal:  Acta Ophthalmol       Date:  2017-10-25       Impact factor: 3.761

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.