Literature DB >> 21530048

Effect of drilling technique on the early integration of plateau root form endosteal implants: an experimental study in dogs.

Gabriela Giro1, Charles Marin, Rodrigo Granato, Estevam A Bonfante, Marcelo Suzuki, Malvin N Janal, Paulo G Coelho.   

Abstract

PURPOSE: This study tested the hypothesis that early integration of plateau root form endosseous implants is significantly affected by surgical drilling technique.
MATERIALS AND METHODS: Sixty-four implants were bilaterally placed in the diaphysial radius of 8 beagles and remained 2 and 4 weeks in vivo. Half the implants had an alumina-blasted/acid-etched surface and the other half a surface coated with calcium phosphate. Half the implants with the 2 surface types were drilled at 50 rpm without saline irrigation and the other half were drilled at 900 rpm under abundant irrigation. After euthanasia, the implants in bone were nondecalcified and referred for histologic analysis. Bone-to-implant contact, bone area fraction occupancy, and the distance from the tip of the plateau to pristine cortical bone were measured. Statistical analyses were performed by analysis of variance at a 95% level of significance considering implant surface, time in vivo, and drilling speed as independent variables and bone-to-implant contact, bone area fraction occupancy, and distance from the tip of the plateau to pristine cortical bone as dependent variables.
RESULTS: The results showed that both techniques led to implant integration and intimate contact between bone and the 2 implant surfaces. A significant increase in bone-to-implant contact and bone area fraction occupancy was observed as time elapsed at 2 and 4 weeks and for the calcium phosphate-coated implant surface compared with the alumina-blasted/acid-etched surface.
CONCLUSIONS: Because the surgical drilling technique did not affect the early integration of plateau root form implants, the hypothesis was refuted.
Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21530048     DOI: 10.1016/j.joms.2011.01.029

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  8 in total

1.  Biophysical regulation of osteotomy healing: An animal study.

Authors:  Liao Wang; Maziar Aghvami; John Brunski; Jill Helms
Journal:  Clin Implant Dent Relat Res       Date:  2017-06-13       Impact factor: 3.932

2.  Osseodensification for enhancement of spinal surgical hardware fixation.

Authors:  Christopher D Lopez; Adham M Alifarag; Andrea Torroni; Nick Tovar; J Rodrigo Diaz-Siso; Lukasz Witek; Eduardo D Rodriguez; Paulo G Coelho
Journal:  J Mech Behav Biomed Mater       Date:  2017-01-13

3.  An Osteotomy Tool That Preserves Bone Viability: Evaluation in Preclinical and Clinical Settings.

Authors:  Oded Bahat; Xing Yin; Stefan Holst; Ion Zabalegui; Eva Berroeta; Javier Pérez; Peter Wöhrle; Norbert Sörgel; John Brunski; Jill A Helms
Journal:  J Clin Med       Date:  2022-04-30       Impact factor: 4.964

Review 4.  Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review.

Authors:  Juan Carlos Bernabeu-Mira; David Soto-Peñaloza; Miguel Peñarrocha-Diago; Fabio Camacho-Alonso; Rebeca Rivas-Ballester; David Peñarrocha-Oltra
Journal:  Clin Oral Investig       Date:  2021-04-24       Impact factor: 3.573

5.  The effect of simplifying dental implant drilling sequence on osseointegration: an experimental study in dogs.

Authors:  Gabriela Giro; Nick Tovar; Charles Marin; Estevam A Bonfante; Ryo Jimbo; Marcelo Suzuki; Malvin N Janal; Paulo G Coelho
Journal:  Int J Biomater       Date:  2013-01-30

6.  The effect of low-speed drilling without irrigation on heat generation: an experimental study.

Authors:  Ji-Hyeon Oh; Yiqin Fang; Seung-Mi Jeong; Byung-Ho Choi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-02-15

7.  A Novel Osteotomy Preparation Technique to Preserve Implant Site Viability and Enhance Osteogenesis.

Authors:  Chih-Hao Chen; Benjamin R Coyac; Masaki Arioka; Brian Leahy; U Serdar Tulu; Maziar Aghvami; Stefan Holst; Waldemar Hoffmann; Antony Quarry; Oded Bahat; Benjamin Salmon; John B Brunski; Jill A Helms
Journal:  J Clin Med       Date:  2019-02-01       Impact factor: 4.241

8.  Radiographic comparisons of crestal bone levels around implants placed with low-speed drilling and standard drilling protocols: Preliminary results.

Authors:  Afsheen Tabassum
Journal:  Saudi Dent J       Date:  2021-08-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.