Literature DB >> 21525041

Comparison of operator radiation exposure between C-arm and O-arm fluoroscopy for orthopaedic surgery.

Moon Seok Park1, Kyoung Min Lee, Boram Lee, Eunki Min, Youhyun Kim, Sungchae Jeon, Young Huh, Kisung Lee.   

Abstract

The O-arm system has recently been introduced and has the capability of combined two-dimensional (2-D) fluoroscopy imaging and three-dimensional computed tomography imaging. In this study, an orthopaedic surgical procedure using C-arm and O-arm systems in their 2-D fluoroscopy modes was simulated and the radiation doses to susceptible organs to which operators can be exposed were investigated. The experiments were performed in four configurations of the location of the X-ray source and detector. Shielding effects on the thyroid surface and the direct exposure delivered to the surgeon's hands were also compared. The results obtained show that the O-arm delivered higher doses to the sensitive organs of the operator in all configurations. The thyroid shield cut-off 89 % of the dose in the posteroanterior configuration of both imaging systems. Thus, the operators need to pay more attention to managing radiation exposure, especially when using the O-arm system.

Mesh:

Year:  2011        PMID: 21525041     DOI: 10.1093/rpd/ncr149

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  9 in total

1.  Measuring the radiation exposed with optically stimulated luminescent dosimeters and evaluation of the total time and dose of fluoroscopy.

Authors:  Sever Çaglar; Yaşar Mahsut Dinçel; Yavuz Arıkan; Osman Nuri Özyalvaç; Barış Özkul; Ali Öner
Journal:  J Clin Orthop Trauma       Date:  2018-07-21

Review 2.  C-arm fluoroscopy in orthopaedic surgical practice.

Authors:  Ishaq Ojodu; Ayodele Ogunsemoyin; Sascha Hopp; Tim Pohlemann; Oluwole Ige; Oluwaseun Akinola
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-23

3.  Radiation exposure using the O-arm® surgical imaging system.

Authors:  Nicolas Pitteloud; Axel Gamulin; Christophe Barea; Jerome Damet; Guillaume Racloz; Marta Sans-Merce
Journal:  Eur Spine J       Date:  2016-09-21       Impact factor: 3.134

4.  Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention.

Authors:  Jae Heon Lee; Gye Rok Jeon; Jung Hoon Ro; Gyeong Jo Byoen; Tae Kyun Kim; Kyung Hoon Kim
Journal:  Korean J Pain       Date:  2012-04-04

5.  Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report.

Authors:  Jacob E Mathew; Kelvin Mok; Benoit Goulet
Journal:  Int J Spine Surg       Date:  2013-12-01

6.  A retrospective comparison of intraoperative CT and fluoroscopy evaluating radiation exposure in posterior spinal fusions for scoliosis.

Authors:  Jacob Riis; Rebecca R Lehman; Robert A Perera; John Ryan Quinn; Patricia Rinehart; Hans Robert Tuten; Victoria Kuester
Journal:  Patient Saf Surg       Date:  2017-12-21

7.  Full-endoscopy with intraoperative O-arm navigation for cervicothoracic gas-containing hemorrhagic synovial cyst: A case report.

Authors:  Yanting Liu; Jin-Sung Kim; Min-Gi Lee; Jun-Yong Cha
Journal:  N Am Spine Soc J       Date:  2022-06-13

8.  Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis.

Authors:  Giuseppe La Rocca; Edoardo Mazzucchi; Fabrizio Pignotti; Luigi Aurelio Nasto; Gianluca Galieri; Alessandro Olivi; Vincenzo De Santis; Pierluigi Rinaldi; Enrico Pola; Giovanni Sabatino
Journal:  J Orthop Traumatol       Date:  2022-09-01

9.  Percutaneous short-segment pedicle instrumentation assisted with O-arm navigation in the treatment of thoracolumbar burst fractures.

Authors:  Peng Yang; Kangwu Chen; Kai Zhang; Jiajia Sun; Huilin Yang; Haiqing Mao
Journal:  J Orthop Translat       Date:  2019-12-05       Impact factor: 5.191

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.