Literature DB >> 21521906

A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation.

Chan Hyeong Kim1, Jong Hwi Jeong, Wesley E Bolch, Kun-Woo Cho, Sung Bae Hwang.   

Abstract

Even though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations. The calculated dose values and computation time were then compared with those of HDRK-Man (High Definition Reference Korean-Man), a corresponding voxel phantom adjusted to the same Reference Korean data from the same VKH-Man voxel phantom. Our results showed that the calculated dose values of the PSRK-Man surface phantom agreed well with those of the HDRK-Man voxel phantom. The calculation speed for the PSRK-Man polygon phantom though was 70-150 times slower than that of the HDRK-Man voxel phantom; that speed, however, could be acceptable in some applications, in that direct use of the surface phantom PSRK-Man in Geant4 does not require a separate voxelization process. Computing speed can be enhanced, in future, either by optimizing the Monte Carlo transport kernel for the polygon surfaces or by using modern computing technologies such as grid computing and general-purpose computing on graphics processing units programming.

Entities:  

Mesh:

Year:  2011        PMID: 21521906     DOI: 10.1088/0031-9155/56/10/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  The Visible Human Projects in Korea and China with improved images and diverse applications.

Authors:  Jing-Xing Dai; Min Suk Chung; Rong-Mei Qu; Lin Yuan; Shu-Wei Liu; Dong Sun Shin
Journal:  Surg Radiol Anat       Date:  2012-03-10       Impact factor: 1.246

2.  Outlining of the detailed structures in sectioned images from Visible Korean.

Authors:  Dong Sun Shin; Jin Seo Park; Hyo Seok Park; Sung Bae Hwang; Min Suk Chung
Journal:  Surg Radiol Anat       Date:  2011-09-25       Impact factor: 1.246

3.  Fetal organ dosimetry for the Techa River and Ozyorsk Offspring Cohorts, part 2: radionuclide S values for fetal self-dose and maternal cross-dose.

Authors:  Matthew R Maynard; Natalia B Shagina; Evgenia I Tolstykh; Marina O Degteva; Tim P Fell; Wesley E Bolch
Journal:  Radiat Environ Biophys       Date:  2014-11-28       Impact factor: 1.925

4.  Fetal organ dosimetry for the Techa River and Ozyorsk offspring cohorts, part 1: a Urals-based series of fetal computational phantoms.

Authors:  Matthew R Maynard; Natalia B Shagina; Evgenia I Tolstykh; Marina O Degteva; Tim P Fell; Wesley E Bolch
Journal:  Radiat Environ Biophys       Date:  2014-11-25       Impact factor: 1.925

5.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

6.  Anthropomorphic dual-lattice voxel models for optimizing image quality and dose.

Authors:  Nina Petoussi-Henss; Helmut Schlattl; Janine Becker; Matthias Greiter; Maria Zankl; Christoph Hoeschen
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-30

Review 7.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

8.  Deformable torso phantoms of Chinese adults for personalized anatomy modelling.

Authors:  Hongkai Wang; Xiaobang Sun; Tongning Wu; Congsheng Li; Zhonghua Chen; Meiying Liao; Mengci Li; Wen Yan; Hui Huang; Jia Yang; Ziyu Tan; Libo Hui; Yue Liu; Hang Pan; Yue Qu; Zhaofeng Chen; Liwen Tan; Lijuan Yu; Hongcheng Shi; Li Huo; Yanjun Zhang; Xin Tang; Shaoxiang Zhang; Changjian Liu
Journal:  J Anat       Date:  2018-04-16       Impact factor: 2.610

9.  The UF family of hybrid phantoms of the developing human fetus for computational radiation dosimetry.

Authors:  Matthew R Maynard; John W Geyer; John P Aris; Roger Y Shifrin; Wesley Bolch
Journal:  Phys Med Biol       Date:  2011-07-15       Impact factor: 3.609

10.  Assessment of radiation dose in nuclear cardiovascular imaging using realistic computational models.

Authors:  Tianwu Xie; Choonsik Lee; Wesley E Bolch; Habib Zaidi
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.