Investigation of a breathing surrogate prediction algorithm for prospective pulmonary gating.

Benjamin M White1, Daniel A Low, Tianyu Zhao, Sara Wuenschel, Wei Lu, James M Lamb, Sasa Mutic, Jeffrey D Bradley, Issam El Naqa.   

Abstract

PURPOSE: A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-specified breathing phases. This study describes the development and testing of an autoregressive moving average (ARMA) model for human respiratory phase prediction under quiet respiration conditions.
METHODS: A total of 47 4DCT patient datasets and synchronized respiration records was utilized in this study. Three datasets were used in model development and were removed from further evaluation of the ARMA model. The remaining 44 patient datasets were evaluated with the ARMA model for prediction time steps from 50 to 1000 ms in increments of 50 and 100 ms. Thirty-five of these datasets were further used to provide a comparison between the proposed ARMA model and a commercial algorithm with a prediction time step of 240 ms.
RESULTS: The optimal number of parameters for the ARMA model was based on three datasets reserved for model development. Prediction error was found to increase as the prediction time step increased. The minimum prediction time step required for prospective gating was selected to be half of the gantry rotation period. The maximum prediction time step with a conservative 95% confidence criterion was found to be 0.3 s. The ARMA model predicted peak inhalation and peak exhalation phases significantly better than the commercial algorithm. Furthermore, the commercial algorithm had numerous instances of missed breath cycles and falsely predicted breath cycles, while the proposed model did not have these errors.
CONCLUSIONS: An ARMA model has been successfully applied to predict human respiratory phase occurrence. For a typical CT scanner gantry rotation period of 0.4 s (0.2 s prediction time step), the absolute error was relatively small, 0.06 +/- 0.02 s at peak inhalation and 0.05 +/- 0.04 s at peak exhalation. The application of the ARMA model for prospective pulmonary gating has been demonstrated.

Entities:  

Mesh:

Year:  2011        PMID: 21520870      PMCID: PMC3060936          DOI: 10.1118/1.3556589

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66.

Authors:  Sasa Mutic; Jatinder R Palta; Elizabeth K Butker; Indra J Das; M Saiful Huq; Leh-Nien Dick Loo; Bill J Salter; Cynthia H McCollough; Jacob Van Dyk
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

2.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy.

Authors:  Gregory C Sharp; Steve B Jiang; Shinichi Shimizu; Hiroki Shirato
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

3.  Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung.

Authors:  Wei Lu; Daniel A Low; Parag J Parikh; Michelle M Nystrom; Issam M El Naqa; Sasha H Wahab; Maureen Handoko; David Fooshee; Jeffrey D Bradley
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

4.  Exploring breathing pattern irregularity with projection-based method.

Authors:  Dan Ruan; Jeffrey A Fessler; James M Balter; Jan-Jakob Sonke
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

5.  Optimization of an adaptive neural network to predict breathing.

Authors:  Martin J Murphy; Damodar Pokhrel
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Free breathing gated delivery (FBGD) of lung radiation therapy: analysis of factors affecting clinical patient throughput.

Authors:  Timothy Fox; Edmund L Simon; Eric Elder; Robert H Riffenburgh; Peter A S Johnstone
Journal:  Lung Cancer       Date:  2006-12-28       Impact factor: 5.705

7.  Novel breathing motion model for radiotherapy.

Authors:  Daniel A Low; Parag J Parikh; Wei Lu; James F Dempsey; Sasha H Wahab; James P Hubenschmidt; Michelle M Nystrom; Maureen Handoko; Jeffrey D Bradley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-11-01       Impact factor: 7.038

8.  Mean position tracking of respiratory motion.

Authors:  Dan Ruan; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

9.  Predicting respiratory motion for four-dimensional radiotherapy.

Authors:  S S Vedam; P J Keall; A Docef; D A Todor; V R Kini; R Mohan
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

10.  A multiple model approach to respiratory motion prediction for real-time IGRT.

Authors:  Devi Putra; Olivier C L Haas; John A Mills; Keith J Burnham
Journal:  Phys Med Biol       Date:  2008-02-25       Impact factor: 3.609

View more
  4 in total

1.  Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.

Authors:  Benjamin M White; Tianyu Zhao; James Lamb; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Modeling and incorporating cardiac-induced lung tissue motion in a breathing motion model.

Authors:  Benjamin M White; Anand Santhanam; David Thomas; Yugang Min; James M Lamb; Jack Neylon; Shyam Jani; Sergio Gaudio; Subashini Srinivasan; Daniel Ennis; Daniel A Low
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

3.  Physiologically guided approach to characterizing respiratory motion.

Authors:  Benjamin M White; Tianyu Zhao; James M Lamb; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

4.  Adaptive respiratory signal prediction using dual multi-layer perceptron neural networks.

Authors:  Wenzheng Sun; Qichun Wei; Lei Ren; Jun Dang; Fang-Fang Yin
Journal:  Phys Med Biol       Date:  2020-09-14       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.